Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biomech Model Mechanobiol ; 22(6): 2083-2096, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37535253

RESUMEN

Automobile crashes and blunt trauma often lead to life-threatening thoracic injuries, especially to the lung tissues. These injuries can be simulated using finite element-based human body models that need dynamic material properties of lung tissue. The strain-rate-dependent material parameters of human parenchymal tissues were determined in this study using uniaxial quasi-static (1 mm/s) and dynamic (1.6, 3, and 5 m/s) compression tests. A bilinear material model was used to capture the nonlinear behavior of the lung tissue, which was implemented using a user-defined material in LS-DYNA. Inverse mapping using genetic algorithm-based optimization of all experimental data with the corresponding FE models yielded a set of strain-rate-dependent material parameters. The bilinear material parameters are obtained for the strain rates of 0.1, 100, 300, and 500 s-1. The estimated elastic modulus increased from 43 to 153 kPa, while the toe strain reduced from 0.39 to 0.29 when the strain rate was increased from 0.1 to 500 s-1. The optimized bilinear material properties of parenchymal tissue exhibit a piecewise linear relationship with the strain rate.


Asunto(s)
Pulmón , Tejido Parenquimatoso , Humanos , Estrés Mecánico , Análisis de Elementos Finitos , Módulo de Elasticidad , Modelos Biológicos
2.
Med Eng Phys ; 96: 46-52, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34565552

RESUMEN

Trans-rectal ultrasound-guided needle biopsy is a well-established diagnosis technique for prostate cancer. To enhance the needle manoeuvring skills under ultrasound (US) guidance, it is preferable to train medical practitioners in needle biopsy on tissue-mimicking phantoms. This phantom should mimic the morphology as well as mechanical and acoustic properties of the human male pelvic region to provide a surgical experience and feedback. In this study, polyvinyl alcohol (PVA) was used and evaluated for prostate phantom development, that is stiffness tunable, US-compatible and durable phantom material. Three samples, each with 5%, 10%, and 15% concentration of PVA material, were prepared, and their mechanical and shrinkage characteristics were investigated. The anatomy of male pelvic region was used to develop an anatomically correct phantom. Later US-guided needle biopsy was performed on the phantom. The range of elastic moduli of the PVA samples was 2∼146 kPa. Their elastic moduli and volumes were found to remain statistically close from seventh to eighth freeze-thaw cycle (p>0.05). Initial US scans of the phantom resulted in satisfactory B-mode images, with a clear distinction between the prostate and its surrounding organs. This study demonstrated the applicability of PVA hydrogel as a phantom material for training in US-guided needle biopsy.


Asunto(s)
Alcohol Polivinílico , Neoplasias de la Próstata , Biopsia con Aguja , Humanos , Masculino , Fantasmas de Imagen , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...