Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 96(25): 10459-10466, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38866706

RESUMEN

Exosomes, as an emerging biomarker, have exhibited remarkable promise in early cancer diagnosis. Here, a highly sensitive, selective, and automatic electrochemiluminescence (ECL) method for the detection of cancerous exosomes was developed. Specific aptamer-(EK)4 peptide-tagged magnetic beads (MBs-(EK)4-aptamer) were designed as a magnetic capture probe in which the (EK)4 peptide was used to reduce the steric binding hindrance of cancerous exosomes with a specific aptamer. One new universal ECL signal nanoprobe (CD9 Ab-PEG@SiO2ϵRu(bpy)32+) was designed and synthesized by using microporous SiO2 nanoparticles as the carrier for loading ECL reagent Ru(bpy)32+, polyethylene glycol (PEG) layer, and anticluster of differentiation 9 antibody (CD9 Ab). A "sandwich" biocomplex was formed on the surface of the magnetic capture probe after mixing the capture probe, target exosomes, and ECL signal nanoprobe, and then it was introduced into an automated ECL analyzer for rapid and automatic ECL measurement. It was found that the designed signal nanoprobe shows a 270-fold improvement in the signal-to-noise ratio than that of the ruthenium complex-labeled CD9 antibody signal probe. The relative ECL intensity was proportional to MCF-7 exosomes as a model in the range of 102 to 104 particle/µL, with a detection limit of 11 particle/µL. Furthermore, the ECL method was employed to discriminate cancerous exosomes based on fingerprint responses using the designed multiple magnetic capture probes and the universal ECL signal nanoprobe. This work demonstrates that the utilization of a designed automated ECL tactic using the MBs-(EK)4-aptamer capture probe and the CD9 Ab-PEG@SiO2ϵRu(bpy)32+ signal nanoprobe will provide a unique and robust method for the detection and discrimination of cancerous exosomes.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Electroquímicas , Exosomas , Mediciones Luminiscentes , Humanos , Exosomas/química , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Mediciones Luminiscentes/métodos , Células MCF-7 , Dióxido de Silicio/química , Técnicas Biosensibles/métodos , Tetraspanina 29/análisis , Polietilenglicoles/química
2.
Anal Bioanal Chem ; 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38937290

RESUMEN

3-Methylhistidine (3-MeHis) is increasingly used as an indicator of muscle protein breakdown. The development of a sensitive, simple, and non-invasive method for 3-MeHis assay is important in clinical practice. Herein, a sensitive, simple, and non-invasive electrogenerated chemiluminescence (ECL) method was proposed for the quantitation of 3-MeHis in urine by using an iridium(III) solvent complex ([Ir(dfppy)2(DMSO)Cl], dfppy = 2-(2,4-difluorophenyl)pyridine, Ir-DMSO) as a signal reagent. The photoluminescence (PL) and ECL responses of Ir-DMSO to 3-MeHis were studied. The ECL intensity of Ir-DMSO was enhanced in the presence of 3-MeHis because of the coordination recognition between Ir-DMSO and the imidazole group of 3-MeHis. Based on the enhancement of ECL intensity, 3-MeHis can be sensitively detected in the range of 5 to 25 µM. The detection limit was 0.4 µM. This is the first report of an ECL method for the quantitation of 3-MeHis. Further, to investigate the feasibility of the Ir-DMSO-based ECL method in practical applications, the developed ECL method was applied for 3-MeHis assay in urine samples of 28 healthy volunteers and 2 patients. The urine samples from patients hospitalized with obesity and kidney disease and healthy individuals were distinguished by the ECL responses of Ir-DMSO. The proposed ECL method based on the coordination recognition between iridium(III) solvent complex and the imidazole group of 3-MeHis allows inexpensive, fast, non-invasive, and sensitive detection of 3-MeHis in urine, which is promising for assessing large volumes of patients for routine analysis in clinical practices.

3.
Anal Chem ; 96(15): 6030-6036, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38569068

RESUMEN

Cysteine (Cys), as one of the biological thiols, is related to many physiological and pathological processes in humans and plants. Therefore, it is necessary to develop a sensitive and selective method for the detection and imaging of Cys in biological organisms. In this work, a novel near-infrared (NIR) fluorescent probe, Probe-Cys, was designed by connecting furancarbonyl, as a new recognition moiety, with Fluorophore-OH via the decomposition of IR-806. The use of the furan moiety is anticipated to produce more effective fluorescence quenching because of the electron-donating ability of the O atom. Probe-Cys has outstanding properties, such as a new recognition group, an emission wavelength in the infrared region at 710 nm, a linear range (0-100 µM), a low detection limit of 0.035 µM, good water solubility, excellent sensitivity, and selectivity without the interference of Hcy, GSH, and HS-. More importantly, Probe-Cys could achieve the detection of endogenous Cys by reacting with the stimulant 1,4-dimercaptothreitol (DTT) and the inhibitor N-ethylmaleimide (NEM) in HepG2 cells and zebrafish. Ultimately, it was successfully applied to obtain images of Arabidopsis thaliana, revealing that the content of Cys in the meristematic zone was higher than that in the elongation zone, which was the first time that the NIR fluorescence probe was used to obtain images of Cys in A. thaliana. The superior properties of the probe exhibit its great potential for use in biosystems to explore the physiological and pathological processes associated with Cys.


Asunto(s)
Arabidopsis , Perciformes , Humanos , Animales , Fluorescencia , Pez Cebra , Cisteína , Células HeLa , Colorantes Fluorescentes , Glutatión
4.
Chem Commun (Camb) ; 60(37): 4926-4929, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38629227

RESUMEN

A turn-on fluorescence aptasensing approach for the highly sensitive and selective determination of 5-HT was proposed via target-induced knot displacement. 5-HT can be determined in a range from 0.5 nM to 100 nM with a limit of detection as low as 0.1 nM and a low dissociation constant of 2.3 nM.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Colorantes Fluorescentes , Serotonina , Espectrometría de Fluorescencia , Aptámeros de Nucleótidos/química , Serotonina/análisis , Serotonina/química , Técnicas Biosensibles/métodos , Colorantes Fluorescentes/química , Límite de Detección , Humanos , Fluorescencia
5.
Biosensors (Basel) ; 14(4)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38667174

RESUMEN

A highly sensitive and selective electrogenerated chemiluminescence (ECL) biosensor was developed for the determination of matrix metalloproteinase 3 (MMP-3) in serum via the target-induced cleavage of an oligopeptide. One ECL probe (named as Ir-peptide) was synthesized by covalently linking a new cyclometalated iridium(III) complex ([(3-pba)2Ir(bpy-COOH)](PF6)) (3-pba = 3-(2-pyridyl) benzaldehyde, bpy-COOH = 4'-methyl-2,2'-bipyridine-4-carboxylic acid) with an oligopeptide (CGVPLSLTMGKGGK). An ECL biosensor was fabricated by firstly casting Nafion and gold nanoparticles (AuNPs) on a glassy carbon electrode and then self-assembling both of the ECL probes, 6-mercapto-1-hexanol and zwitterionic peptide, on the electrode surface, from which the AuNPs could be used to amplify the ECL signal and Ir-peptide could serve as an ECL probe to detect the MMP-3. Thanks to the MMP-3-induced cleavage of the oligopeptide contributing to the decrease in ECL intensity and the amplification of the ECL signal using AuNPs, the ECL biosensor could selectively and sensitively quantify MMP-3 in the concentration range of 10-150 ng·mL-1 and with both a limit of quantification (26.7 ng·mL-1) and a limit of detection (8.0 ng·mL-1) via one-step recognition. In addition, the developed ECL biosensor showed good performance in the quantization of MMP-3 in serum samples, with a recovery of 92.6% ± 2.8%-105.6% ± 5.0%. An increased level of MMP-3 was found in the serum of rheumatoid arthritis patients compared with that of healthy people. This work provides a sensitive and selective biosensing method for the detection of MMP-3 in human serum, which is promising in the identification of patients with rheumatoid arthritis.


Asunto(s)
Técnicas Biosensibles , Oro , Mediciones Luminiscentes , Metaloproteinasa 3 de la Matriz , Nanopartículas del Metal , Oligopéptidos , Humanos , Metaloproteinasa 3 de la Matriz/sangre , Oro/química , Nanopartículas del Metal/química , Luminiscencia , Límite de Detección , Electrodos , Técnicas Electroquímicas
6.
Mikrochim Acta ; 191(3): 143, 2024 02 17.
Artículo en Inglés | MEDLINE | ID: mdl-38368295

RESUMEN

An enzyme immunoassay was developed based on the coulometric measurement of immunoglobulin M (IgM) against Hantaan viruses (HTNV) by using virus-like particles (VLPs) as recognition molecules. The surface functionalization of screen-printed carbon electrodes (SPCEs) was achieved through paste-exfoliated graphene that was modified with a COOH group and a thionine mediator through supramolecular-covalent scaffolds, on SPCEs by using the binder contained in the ink. After the covalent immobilization of the antibody, the sensor was used for the sandwich enzyme immunoassay of IgM against HTNV. By using HTNV VLPs as the second recognization molecules, the resulting sensor efficiently monitored the reaction of IgM against HTNV and anti-IgM antibody with high specificity. By attaching HTNV nucleocapsid protein antibody conjugate with horseradish peroxidase (HRP) onto VLPs, the signal response of the assay was derived from the coulometric measurement of H2O2 reduction mediated by thionine on the electrode surface after the application of a potential (- 0.2 V vs. Ag/AgCl). The ratio of charges measured before or after H2O2 addition was used to quantify IgM because these charges could be used as background charges or total charges, respectively. The ratio exhibited good agreement with IgM concentration within a range 0.1 to 1000 pg mL-1, and a detection limit of 0.06 pg mL-1 was obtained. The assay demonstrated high sensitivity and specificity toward HTNV-specific IgM in serum.


Asunto(s)
Técnicas Biosensibles , Grafito , Fenotiazinas , Grafito/química , Carbono/química , Inmunoensayo/métodos , Técnicas Biosensibles/métodos , Peróxido de Hidrógeno/química , Inmunoglobulina M , Electrodos
7.
Anal Chem ; 96(1): 446-454, 2024 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-38124437

RESUMEN

Histidine (His) and its metabolite analysis is significant due to their vital roles in the diagnosis of diseases. In practical applications, simple and effective detection and discrimination of these metabolic species are still a great challenge due to their highly similar structures. Herein, photoluminescence (PL)-electrochemiluminescence (ECL) dual-mode sensor arrays consisting of a series of sensing elements were proposed for simultaneous quantitation and accurate discrimination of His and its four key metabolites (including histamine, imidazole-4-acetic acid, N-acetylhistamine, and imidazole propionate). The sensing elements of these sensor arrays were constructed by employing two solvent iridium(III) complexes ([Ir(pbz)2(DMSO)Cl] and [Ir(ppy)2(DMSO)Cl], pbz = 3-(2-pyridyl)benzoic acid, ppy = 2-phenylpyridine) with excellent PL and ECL performances as cross-responsive sensing units. Based on diverse coordination abilities of the two complexes with the imidazole group of the five targets, PL and ECL responses of each sensing unit can be enhanced to various degrees, which generate unique fingerprint patterns for the corresponding targets. Through principal component analysis, the multifarious patterns (two-, three-, and four-element sensor arrays) can be transformed into simple visualization modes, from which His and its four key metabolites can be effectively discriminated against each other. Moreover, the quantitation of an individual metabolic species at different concentrations and the recognition of the mixtures with different ratios were also accurately achieved. Notably, His and its four key metabolites in urine can also be successfully discriminated by the as-fabricated sensor arrays, and the patients with kidney diseases can be identified clearly, providing a promising way for disease diagnosis.


Asunto(s)
Dimetilsulfóxido , Histidina , Humanos , Fotometría , Mediciones Luminiscentes
8.
Analyst ; 148(24): 6253-6260, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-37937443

RESUMEN

A novel point-of-care testing (POCT) method for the determination of proteases was developed for the first time using a designed disposable capillary-fill device based on the cleavage of electrogenerated chemiluminescence (ECL)-label-tagged peptide probes and enabling elimination of the light-shielding from the magnetic beads (MBs). As a proof-of-principle, prostate-specific antigen (PSA) was taken as a model analyte, and streptavidin-coated magnetic beads bound with ruthenium-complex-tagged specific peptide (biotin-HSSKLQK) were utilized as MB ECL probes. The capillary-fill device was designed to be divided into a reaction zone and detection zone. In the reaction zone, the bio-cleavage reaction between the PSA analyte with the peptide on the surface of the MB ECL probes occurred, while in the detection zone, ECL emission was produced by a screen-printed carbon electrode, Ag/AgCl reference electrode and carbon counter electrode. When the analyte PSA was introduced into the suspension of MB ECL probes in the reaction zone of the device, biocleavage of the peptide occurred, and the cleaved Ru1 part was released from the surface of the MB ECL probes. The capillary-filled device was tilted 90°, and with the aid of gravity, the solution containing the released Ru1 part flowed to the surface of the working electrode in the detection region of the device, while the MB ECL probes were fixed in the reaction zone by an external magnet. PSA can be determined by the ECL emission from the released Ru1 part in the presence of the co-reactant tri-n-propylamine at the detection zone. Under the optimal conditions, the developed ECL method showed a low detection limit of 0.12 ng mL-1 for PSA. This work demonstrates that the developed ECL biosensing approach can eliminate the MB light-shielding effect and quantify proteases with high sensitivity and selectivity, which could be easily extended to POCT-based ECL biosensing for other proteases.


Asunto(s)
Técnicas Biosensibles , Péptido Hidrolasas , Humanos , Masculino , Antígeno Prostático Específico , Luminiscencia , Péptidos , Carbono , Mediciones Luminiscentes/métodos , Técnicas Biosensibles/métodos
9.
Mikrochim Acta ; 190(10): 422, 2023 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-37775573

RESUMEN

An electrochemiluminescence (ECL) bioassay with high sensitivity and anti-fouling ability was developed for determination of matrix metalloproteinase 9 (MMP-9) secreted from living cells under external stimulation. A peptide with sequence of CLGRMGLPGK and a new cyclometalated iridium(III) complex bearing carboxyl group, (pq)2Ir(dcbpy) (pq = 2-phenylquinoline, dcbpy = 2,2'-bipyridyl-4,4'-dicarboxyli acid, abbreviated as Ir) were employed as molecular recognition substrate and ECL emitter, respectively. The peptide was labelled with the Ir to form Ir-peptide as ECL probe. Ir-peptide was self-assembled onto Nafion and gold nanoparticles (AuNPs) modified glassy carbon electrode (AuNPs/Nafion/GCE) and then both of 6-mercapto-1-hexanol (MCH) and zwitterionic peptide as blocking reagents were co-assembled on Ir-peptide/AuNPs/Nafion/GCE to form an anti-fouling ECL peptide-based biosensor. MMP-9 can be quantified in the range 1.0-50 ng·mL-1 with a detection limit of 0.50 ng·mL-1 based on the decreased ECL intensity. Relative standard derivation was 2.3% for six fabricated anti-fouling ECL peptide-based biosensors after reaction with 50 ng·mL-1 MMP-9. The anti-fouling ECL peptide-based biosensor can be used to monitor MMP-9 secreted from living cells under external stimulation. 96.0%-108.0% of recoveries were obtained in 60-diluted cell culture media. This study demonstrates that the ECL biosensor by the combination of iridium(III) complex-based sensitive ECL method and the anti-fouling interface provides a promising way for the determination of MMP-9 in biological sample, which is viable in clinical diagnosis and point-of-care test of protease.


Asunto(s)
Incrustaciones Biológicas , Nanopartículas del Metal , Oro/química , Metaloproteinasa 9 de la Matriz , Iridio , Incrustaciones Biológicas/prevención & control , Mediciones Luminiscentes/métodos , Nanopartículas del Metal/química , Péptidos/química
10.
Chem Commun (Camb) ; 59(58): 8941-8944, 2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37394953

RESUMEN

A sensitive and noninvasive cyclic peptide-based electrogenerated chemiluminescence biosensing method for the determination of sweat glucose was developed. Glucose can be quantified in sweat samples with a recovery of 93%-113% via one-step recognition, which is promising for the determination of sweat glucose.


Asunto(s)
Técnicas Biosensibles , Péptidos Cíclicos , Sudor , Glucosa , Luminiscencia , Técnicas Biosensibles/métodos , Mediciones Luminiscentes/métodos
11.
Langmuir ; 39(19): 6681-6690, 2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37140168

RESUMEN

The understanding of the dissolution processes of solids is important for the design and synthesis of solids in a controlled and precise manner and for predicting their fate in the aquatic environment. We report herein single-particle-based confocal laser scanning microscopy (CLSM) for tracking the dissolution surface kinetics of a single fluorescent cyclodextrin metal-organic framework (CD-MOF). As a proof of concept, CD-MOF containing fluorescein, named as CD-MOF⊃FL, was synthesized by encapsulating fluorescein into the interior of CD-MOF via a vapor diffusion method and used as a single-particle dissolution model because of its high FL efficiency and unique structure. The morphology of CD-MOF⊃FL and the distribution of fluorescein within CD-MOF⊃FL were characterized. The growth and dissolution processes of CD-MOF⊃FL at the single-particle level were visualized and quantified for the first time by recording the change of the fluorescence emission. Three processes, including nucleation, germination growth, and saturation stage, were found in the growth of CD-MOF⊃FL, and the growth kinetics followed Avrami's model. The dissolution rate at the face of a single CD-MOF⊃FL crystal was slower than that of its arris, and the dissolution rate of the CD-MOF⊃FL crystal was increased with the increase of the water amount in methanol solution. The dissolution process of the CD-MOF⊃FL crystal was a competitive process of erosion and diffusion in different methanol aqueous solutions, and the dissolution kinetics followed the Korsmeyer-Peppas model. These results offer new insights into the nature of dissolution kinetics of CD-MOF⊃FL and provide new venues for the quantitative analysis of solid dissolution and growth at the single-particle level.

12.
Talanta ; 259: 124485, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37019008

RESUMEN

This work reports the performance enhancement strategies on magnetic beads (MBs)-based electrochemiluminescence (ECL) platforms by using double magnetic field actuation of the ECL magnetic microbiosensors (MMbiosensors) for highly sensitive determination of cancer biomarker and exosomes. To obtain the high sensitivity and reproducibility of the ECL MMbiosensors, a series of strategies have been developed including replacing a conventional photomultiplier tube (PMT) with a diamagnetic PMT, replacing the stacked ring-disc magnets with circular-disc magnets lain-in glassy carbon electrode, adding a pre-concentration process of MBs using external magnet actuation. For fundamental research, the ECL MBs taken as the substitute of ECL MMbiosensors were prepared by binding biotinylated DNA tagged with Ru(bpy)32+ derivative (Ru1) to streptavidin-coated MB(MB@SA) were which showed that the developed strategies can enhance 45-fold sensitivity. Importantly, the developed MBs-based ECL platform was estimated by determination of prostate specific antigen (PSA) and exosomes. For PSA, MB@SA•biotin-Ab1(PSA) was taken as the capture probe and Ru1-labeled Ab2 (PSA) was done as ECL probe, while for exosomes, MB@SA•biotin-aptamer (CD63) was taken as the capture probe and Ru1-labeled Ab (CD9) was done as the ECL probe. The experiment results showed that the developed strategies can enhance 33-fold sensitivity of ECL MMbiosensors for PSA and exosomes. The detection limit is 0.28 ng mL-1 for PSA and 4.9 × 102 particle mL-1 for exosomes. This work demonstrated that a series of proposed magnetic field actuation strategies greatly increase the sensitivity of the ECL MMbiosensors. The developed strategies can be expanded to MBs-based ECL and electrochemical biosensors for clinical analysis with greater sensitivity.


Asunto(s)
Técnicas Biosensibles , Exosomas , Neoplasias , Masculino , Humanos , Biomarcadores de Tumor , Antígeno Prostático Específico , Reproducibilidad de los Resultados , Técnicas Biosensibles/métodos , Mediciones Luminiscentes/métodos , Fenómenos Magnéticos , Campos Magnéticos , Neoplasias/diagnóstico
13.
Anal Chem ; 95(13): 5500-5506, 2023 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-36967489

RESUMEN

A label-free electrogenerated chemiluminescence (ECL) aptasensing method for highly sensitive determination of dopamine (DA) was developed based on target-induced DNA conformational change. After anti-DA specific aptamer, as molecular recognition element, was hybridized with a capture ss-DNA (complementary with the aptamer), the formed double-strand DNA (ds-DNA) was self-assembled onto the surface of a gold electrode, and then Ru(phen)32+, as ECL reagent, was intercalated into ds-DNA to form an ECL biosensing platform. In the presence of DA, DA bound with its aptamer and target-induced DNA conformational change occurred, resulting in the dissociation of ds-DNA, the release of intercalated Ru(phen)32+ from the electrode surface, and the decrease of ECL intensity. For comparison, an ECL aptamer-based biosensing method using an ECL reagent-labeled aptamer was also developed for DA assay based on target-induced DNA conformational change. Because of the increase in the amount of ECL reagent into ds-DNA over that of the single-site ECL reagent-labeled aptamer, an obvious increase of ECL intensity was found at the ds-DNA modified electrode over the aptamer modified electrode. DA can be sensitively detected with a lower detection limit of 0.05 nM in the range from 0.1 to 100 nM. With the recognition of the aptamer for DA, DA can be selectively and sensitively detected in artificial cerebrospinal fluid and serum samples without interference from common small molecules. This work demonstrates that the combination of the direct transduction of specific recognition of DA and its aptamer into an ECL signal with Ru(phen)32+ intercalated ds-DNA amplification provides a promising strategy for the development of a simple, sensitive, and selective method for DA assay, which is of great importance in neurochemical assays and clinical diagnosis.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Dopamina , Luminiscencia , Mediciones Luminiscentes/métodos , ADN/química , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos
14.
Anal Chim Acta ; 1253: 340926, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36965986

RESUMEN

This work reports washing-free electrogenerated chemiluminescence (ECL) magnetic microbiosensors based on target assistant proximity hybridization (TAPH) for multiple protein biomarkers for the first time. As a principle-of-proof, alpha-fetoprotein (AFP) was chosen as a model analyte, and biotin-DNA1 bound streptavidin-coated magnetic microbeads (MMB@SA⋅biotin-DNA1) were designed as the universal capture MMB, while the corresponding two antibodies tagged with DNA2 or DNA3 were utilized as hybrid recognition probes, and ruthenium complex-tagged DNA4-10A was designed as a universal ECL signal probe. When the capture MMB was added into the mixture solution (containing the analyte, hybrid recognition probes, signal probe and tri-n-propylamine), biocomplexes were formed on the MMB. After the resulting MMB was efficiently brought to the surface of a magnetic glassy carbon electrode (MGCE), ECL measurement was performed without a washing step, resulting in an increase in the ECL intensity. A model for ECL measuring the second-order rate constants of hybridization reactions on MMB was derived. It was found that the rate constants for hybridization reactions on MMB in rotating mode are 1.6-fold higher than those in shaking mode, and a suitable DNA length of the signal probe can improve the signal-to-noise ratio. The washing-free ECL method was developed for the determination of AFP with a much lower detection limit (LOD) of 0.04 ng mL-1. The developed flexible strategy has been extended to determine D-dimer with an LOD of 0.1 ng mL-1 and myoglobinglobin with an LOD of 1.1 ng mL-1. This work demonstrated that the proposed strategy of ECL TAPH on MMB at MGCE is a washing-free and flexible promising strategy, and can be extended to qualify other multiple protein biomarkers in real clinical assays.


Asunto(s)
Técnicas Biosensibles , alfa-Fetoproteínas , Luminiscencia , Hibridación de Ácido Nucleico , Biomarcadores , Mediciones Luminiscentes/métodos , Técnicas Biosensibles/métodos
15.
Chem Commun (Camb) ; 59(24): 3507-3522, 2023 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-36820650

RESUMEN

This Feature Article simply introduces principles and mechanisms of electrochemiluminescence (ECL) biosensors for the determination of biomarkers and highlights recent advances of ECL biosensors on key aspects including new ECL reagents and materials, new biological recognition elements, and emerging construction biointerfacial strategies with illustrative examples and a critical eye on pitfalls and discusses challenges and perspectives of ECL biosensors for health analysis.


Asunto(s)
Técnicas Biosensibles , Mediciones Luminiscentes , Técnicas Electroquímicas
16.
Bioelectrochemistry ; 150: 108368, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36634465

RESUMEN

Development of rapid and sensitive method for the discrimination of bases in oligonucleotides is of great importance in clinical diagnosis. Here, we demonstrate the first case of single iridium(III) solvent complex-based electrogenerated chemiluminescence (ECL) and photoluminescence (PL) sensor array for the discrimination of bases in oligonucleotides. One iridium (III) solvent complex ([Ir(ppy)2(DMSO)Cl], ppy = 2-phenylpyridine, probe 1) was designed as both ECL and PL probe while five bases (guanine, adenine, cytosine, thymine and uracil) were chosen as analytes. Two-element sensor array was built for the discrimination of five bases based on the fingerprint response of probe 1 to bases via coordination interactions. The combination of unique ECL and PL variations with principal component analysis was applied for the quantitative analysis of five bases in a linear range of 1.0 µM-10 µM and for the effective discrimination of individual base, the mixture of bases and oligonucleotides. Moreover, the sensor array was successfully applied to discriminate different mismatched ss-DNAs from HIV gene (a fully-matched ss-DNA), even at single-base difference. This work demonstrates that the sensor array using single iridium (III) solvent complex is a promising approach for the discrimination of bases with good sensitivity and simpleness in clinical diagnosis.


Asunto(s)
Iridio , Luminiscencia , Humanos , Solventes , Oligonucleótidos
17.
Chem Asian J ; 18(6): e202201284, 2023 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-36719254

RESUMEN

We report the rational design of the matrix-free carbon dots (C-dots) with long wavelength and wavelength-tunable room-temperature phosphorescence (RTP). Taking advantage of microwave-assisted heating treatment, three RTP C-dots in boric acid (BA) composites are synthesized by using diethylenetriaminepentakis (methylphosphonic acid) as a multiple-sites crosslink agent, a moderately acid catalyst and P source; phenylenediamines (either o-PD, m-PD, or p-PD, respectively) as building block while BA as a carbonization-retardant matrix. After the water-soluble BA matrix is removed by dialysis, three matrix-free C-dots are obtained with RTP emission at 540, 550 and 570 nm under an excitation wavelength of 365 nm. Alterations of RTP emission of three matrix-free C-dots are ascribed to the difference in their particle size and band gap from n-π* transition. Furthermore, the application of three matrix-free C-dots are successfully performed in information encryption and decryption.

18.
Chem Commun (Camb) ; 58(92): 12847-12850, 2022 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-36317411

RESUMEN

Mechano-chromic and mechano-enhanced electrogenerated chemiluminescence (ECL) from tetra[4-(4-cyanophenyl)phenyl]ethene (TCPPE) is reported for the first time. TCPPE displays intense mechano-enhanced ECL (ΦECL,crystal = 12.1%, ΦECL,ground = 75.5%) and contrastingly mechano-chromic ECL (λECL,crystal = 478 nm, λECL,ground = 528 nm). The application of TCPPE as sensitive bi-functional mechanical force reporters is successfully performed in rewritable and optical-recording applications.

19.
Analyst ; 147(15): 3444-3450, 2022 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-35792747

RESUMEN

Heat shock protein 70 (Hsp70), belonging to the heat shock protein (HSP) family, is reported to be a potential diagnostic biomarker. In this work, a lateral flow immunostrip was fabricated for the sensitive and rapid determination of Hsp70 by the incorporation of fluorescence and upconversion nanoparticle probes. The upconversion nanoparticles (UCNPs, size ∼39 nm, λex = 980 nm; λem = 540 nm) consisting of a NaYF4:Yb/Er core and polyacrylic acid-modified shell were covalently coupled with Hsp70 antibodies to form the signal probe, which was characterized by dynamic light scattering and zeta potential analyses. The lateral flow assay (LFA) was constructed based on the sandwich-type immunoassay using a sample pad, a test pad, and an adsorption pad on a PVP backing. Hsp70 antibody, IgG antibody and the signal probe were separately dropped on the test zone, the control zone of the test pad, and the sample pad, respectively. In the sandwich LFA, since two antibodies bind to Hsp70 antigenic epitopes, i.e. specific binding, it provided superior specificity and high sensitivity, making it an ideal sensing platform for complex samples like serum Hsp70 samples. The important parameters for the preparation of the lateral flow immunostrips were optimized. Under the optimized conditions, Hsp70 can be detected using the increased fluorescence intensity of UCNPs with a wide linear range from 0.11 to 12 ng mL-1, low detection limit of 0.06 ng mL-1, small sample volume (120 µL), short assay time (15 min) and good reproducibility. The fluorescence method was successfully applied in the determination of Hsp70 in serum samples with good recovery. By combining the accessibility of the lateral flow immunostrips and upconversion nanoparticles, the fluorescence method can serve as a point-of-care testing method for protein assays with high sensitivity and fast detection.


Asunto(s)
Colorantes Fluorescentes , Nanopartículas , Anticuerpos , Proteínas HSP70 de Choque Térmico , Inmunoensayo/métodos , Nanopartículas/química , Reproducibilidad de los Resultados
20.
Bioelectrochemistry ; 146: 108148, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35504227

RESUMEN

Dopamine (DA) is an important neurotransmitter associated with many diseases. It is very significant to detect DA with high sensitivity and good selectivity. Here, a sensitive and selective electrogenerated chemiluminescence (ECL) aptasensing method was developed for the determination of DA based on target-induced conformational displacement. An anti-DA specific aptamer spliting into two ss-DNA (S1 and S2) was used as molecular recognition elements while an ss-DNA labeled with ferrocene (Fc-CS1, complementary to S1) was used as quenching probe. An ECL platform was prepared by dropping the mixture of Nafion, gold nanoparticles (AuNPs) and Ru(bpy)32+ onto glassy carbon electrode (GCE). After hybridization of S1 and Fc-CS1, ds-DNA (S1-CS1-Fc) was self-assembled onto the ECL platform to form an ECL aptasensing platform. In the presence of DA and S2, a S1-S2-DA complex was formed and then Fc-CS1 was released from the electrode surface, resulting in an increase of ECL intensity. DA can be sensitively detected in the range of 1.0 × 10-9 M to 5 × 10-8 M with a lower detection limit of 0.32 nM. This is first report of ECL aptasensing method for the determination of DA based on target-induced conformational displacement. The proposed ECL aptasensing method, exploiting both the aptamer recognition and ECL detection, allows direct detection of DA in diluted serum samples with high sensitivity and good selectivity, which may be further applicable in other neurochemicals assay and biomedical research.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Técnicas Biosensibles/métodos , ADN/química , Dopamina , Oro/química , Luminiscencia , Mediciones Luminiscentes/métodos , Nanopartículas del Metal/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...