Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Science ; 365(6460): 1418-1424, 2019 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-31604269

RESUMEN

Thermoelectric technology allows conversion between heat and electricity. Many good thermoelectric materials contain rare or toxic elements, so developing low-cost and high-performance thermoelectric materials is warranted. Here, we report the temperature-dependent interplay of three separate electronic bands in hole-doped tin sulfide (SnS) crystals. This behavior leads to synergistic optimization between effective mass (m*) and carrier mobility (µ) and can be boosted through introducing selenium (Se). This enhanced the power factor from ~30 to ~53 microwatts per centimeter per square kelvin (µW cm-1 K-2 at 300 K), while lowering the thermal conductivity after Se alloying. As a result, we obtained a maximum figure of merit ZT (ZT max) of ~1.6 at 873 K and an average ZT (ZT ave) of ~1.25 at 300 to 873 K in SnS0.91Se0.09 crystals. Our strategy for band manipulation offers a different route for optimizing thermoelectric performance. The high-performance SnS crystals represent an important step toward low-cost, Earth-abundant, and environmentally friendly thermoelectrics.

2.
Molecules ; 18(10): 12192-207, 2013 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-24084022

RESUMEN

A rapid resolution liquid chromatography/time-of-flight tandem mass spectrometry (RRLC-TOF/MS) method was developed for qualitative and quantitative analysis of the major chemical constituents in Andrographis paniculata. Fifteen compounds, including flavonoids and diterpenoid lactones, were unambiguously or tentatively identified in 10 min by comparing their retention times and accurate masses with standards or literature data. The characteristic fragmentation patterns of flavonoids and diterpenoid lactones were summarized, and the structures of the unknown compounds were predicted. Andrographolide, dehydroandrographolide and neoandrographolide were further quantified as marker substances. It was found that the calibration curves for all analytes showed good linearity (R² > 0.9995) within the test ranges. The overall limits of detection (LODs) and limits of quantification (LOQs) were 0.02 µg/mL to 0.06 µg/mL and 0.06 µg/mL to 0.2 µg/mL, respectively. The relative standard deviations (RSDs) for intra- and inter-day precisions were below 3.3% and 4.2%, respectively. The mean recovery rates ranged from 96.7% to 104.5% with the relative standard deviations (RSDs) less than 2.72%. It is concluded that RRLC-TOF/MS is powerful and practical in qualitative and quantitative analysis of complex plant samples due to time savings, sensitivity, precision, accuracy and lowering solvent consumption.


Asunto(s)
Andrographis/química , Medicamentos Herbarios Chinos/aislamiento & purificación , Calibración , Cromatografía Líquida de Alta Presión , Diterpenos/química , Diterpenos/aislamiento & purificación , Medicamentos Herbarios Chinos/química , Etanol/química , Flavonas/química , Flavonas/aislamiento & purificación , Glucósidos/química , Glucósidos/aislamiento & purificación , Límite de Detección , Extracción en Fase Sólida , Solventes , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Tetrahidronaftalenos/química , Tetrahidronaftalenos/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...