Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Intervalo de año de publicación
1.
JACC Case Rep ; 29(15): 102447, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39157557

RESUMEN

An 83-year-old woman presented 9 years after Tendyne transcatheter mitral valve replacement with acute severe decompensated heart failure. Transesophageal echocardiography reported severe transvalvular mitral regurgitation caused by degenerated Tendyne leaflets. A transfemoral transseptal valve-in-Tendyne procedure using a 26-mm SAPIEN device resulted in significant mitral regurgitation reduction and symptomatic recovery.

2.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627820

RESUMEN

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombocitopenia , Humanos , Válvula Aórtica/cirugía , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Bioprótesis/efectos adversos , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Trombocitopenia/etiología , Factores de Riesgo , Progresión de la Enfermedad
3.
J Cardiothorac Surg ; 19(1): 95, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355617

RESUMEN

BACKGROUND: Rapid-deployment aortic valve replacement (RDAVR) is an alternative to conventional AVR (cAVR) for aortic stenosis. Benefits include a reduction in operative times, facilitation of minimal access surgery and superior haemodynamics compared to conventional valves. However, further evidence is required to inform guidelines, preferably in the form of propensity-matched studies that include mid-term follow-up data. METHODS: This was a single-centre, retrospective, propensity-matched cohort study comparing the Perceval and conventional Perimount Magna Ease valve for short- and mid-term clinical parameters and size-matched mid-term echocardiographic parameters (n = 102 in both groups) from 2014 to 2020. Data were extracted from a nationally managed dataset. RESULTS: There were no demographic differences between the matched groups. The Perceval group had shorter cross-clamp time (Perceval 62 [49-81] minutes; Perimount 79 [63-102] minutes, P < 0.001), shorter bypass time (Perceval 89 [74-114] minutes; Perimount 104 [84-137] minutes, P < 0.001), and more frequent minimally-invasive approaches (Perceval 28%; Perimount 5%, P < 0.001). Size-matched haemodynamics showed initially higher gradients in the Perceval group, but haemodynamics equalised at 12 + months. The Perceval group had a more favourable % change in the left ventricular posterior wall dimension at 2 + years (Perceval - 4.8 ± 18; Perimount 17 ± 2). CONCLUSIONS: The Perceval facilitated shorter operations, which may benefit intermediate-high-risk, elderly patients with comorbidities requiring concomitant procedures. It also facilitated minimally invasive surgery. Size-matched haemodynamic performance was similar at mid-term follow-up, with the Perceval possibly better facilitating regression of left ventricular hypertrophy.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Estudios Retrospectivos , Estudios de Cohortes , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología
4.
Rev. bras. cir. cardiovasc ; 34(5): 610-614, Sept.-Oct. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1042030

RESUMEN

Abstract In cases of aortic valve disease, prosthetic valves have been increasingly used for valve replacement, however, there are inherent problems with prostheses, and their quality in the so-called Third World countries is lower in comparison to new-generation models, which leads to shorter durability. Recently, transcatheter aortic valve replacement has been explored as a less invasive option for patients with high-risk surgical profile. In this scenario, aortic valve neocuspidization (AVNeo) has emerged as another option, which can be applied to a wide spectrum of aortic valve diseases. Despite the promising results, this procedure is not widely spread among cardiac surgeons yet. Spurred on by the last publications, we went on to write an overview of the current practice of state-of-the-art AVNeo and its results.


Asunto(s)
Humanos , Válvula Aórtica/cirugía , Pericardio/trasplante , Trasplante Autólogo/métodos , Glutaral/uso terapéutico , Anuloplastia de la Válvula Cardíaca/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Reoperación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...