Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Cureus ; 12(6): e8467, 2020 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-32642373

RESUMEN

Introduction Pulmonary tuberculosis (PTB) is caused by species of organisms in the Mycobacterium tuberculosis complex. It is a major public health problem worldwide and is endemic in Pakistan. Various clinical and biochemical markers exist for its diagnosis. Radiology has an important role in the diagnosis of PTB. Initially, a chest radiograph is warranted for PTB evaluation. High-resolution computed tomography (HRCT) also has high sensitivity and specificity for PTB diagnosis. Features of primary TB include consolidation, lymphadenopathy, pleural effusion and miliary nodules whereas post-primary TB include apical consolidation, nodules and cavitation. The aim of this study was to determine the diagnostic accuracy of HRCT chest in diagnosing sputum smear positive and smear negative PTB. Methods A cross-sectional study was conducted at a large tertiary care teaching hospital. A retrospective review of medical records of patients who underwent HRCT chest and sputum acid-fast bacillus (AFB) direct smear and AFB culture for suspicion of PTB was undertaken. All HRCT chest examinations were performed on multislice computed tomography (CT) scanner. On HRCT, PTB was defined as the presence of consolidation, centrilobular nodules, branching nodules with tree in bud appearance with or without lymphadenopathy and pleural effusion. Diagnostic accuracy of HRCT including sensitivity, specificity, positive and negative predictive values was calculated using 2 x 2 table, taking findings of AFB culture as a gold standard. Results A total of 108 patients were included in this study with a mean age of 51.85 ± 16.86 years. Diagnostic accuracy of HRCT in diagnosing PTB was found to be 84.26% with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 89.09%, 79.25%, 81.67%, and 87.50%, respectively. In sputum smear positive patients, HRCT has diagnostic accuracy, sensitivity, specificity, PPV and NPV of 87.50%, 88.57%, 84.62%, 93.94%, and 73.33%, respectively. In sputum smear negative patients, HRCT has diagnostic accuracy, sensitivity, specificity, PPV and NPV of 81.67%, 90.00%, 77.50%, 66.67%, and 93.94%, respectively. Conclusion HRCT has high sensitivity in diagnosing sputum smear positive and sputum smear negative PTB. The specificity of HRCT in diagnosing sputum smear positive PTB was high, whereas it was slightly low in diagnosing sputum smear negative PTB. Overall diagnostic accuracy of HRCT was high in diagnosing PTB.

2.
Cureus ; 11(11): e6120, 2019 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-31886058

RESUMEN

Introduction Pulmonary nodules are frequently encountered during chest imaging, and its evaluation is usually done by chest radiograph and computed tomography (CT) scan of chest. High resolution of multidetector CT (MDCT) has improved the nodule detection. Post processing techniques such as maximum intensity projection (MIP) can further improve the sensitivity of MDCT for nodule detection. Failure to diagnose malignancy in pulmonary nodules can delay the treatment. Therefore, the aim of this study was to determine the diagnostic accuracy of MIP in the diagnosis of malignant pulmonary nodules taking histopathology findings as gold standard. Materials and methods A retrospective cross-sectional study was conducted at Dow Institute of Radiology, Dow University of Health Sciences, from 1 December 2018 till 30 June 2019. Both male and female patients aged 18 years and above who underwent CT scan of chest with suspicion of pulmonary nodules were included. Patients already diagnosed with malignant pulmonary nodules and presenting for follow-up were excluded. Contrast-enhanced CT chest was performed on a multi-slice scanner. MIP reconstruction and evaluation was performed on the workstation. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of MIP were calculated taking histopathology findings as gold standard. Results A total of 202 patients were included in this study. The mean age of the patients was 55.87 ± 13.08 years. A total of 103 patients (51.0%) were males and 99 patients (49.0%) were females. There were 131 (64.9%) nodules with smooth margins and 71 (35.1%) nodules with irregular margins. The mean size of nodule was 3.1 ± 0.7 cm. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of MIP in diagnosing malignant pulmonary nodules were found to be 85.82%, 82.35%, 90.55%, 74.67%, and 84.65%, respectively, taking histopathology findings as gold standard. The nodules >3 cm in size had a higher sensitivity for diagnosing malignant pulmonary nodules. Smooth margin nodule had high sensitivity, specificity, and diagnostic accuracy for diagnosing malignant pulmonary nodules. Conclusion MIP images have high sensitivity, specificity, and diagnostic accuracy in the diagnosis of malignant pulmonary nodules. The utilization of MIP images can aid in the detection of malignant pulmonary nodules and help in formulating early treatment strategies for the patients. Other post processing techniques such as volume rendering and computer-aided detection can help in further improving patient care.

3.
Cureus ; 11(12): e6398, 2019 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-31942266

RESUMEN

Introduction Perianal fistula refers to abnormal communication between perianal skin and anal canal. Magnetic resonance imaging (MRI) and endoanal ultrasound have been used in the evaluation of perianal fistula. Endoanal ultrasound is a cost-effective but operator-dependent technique. MRI provides accurate details regarding anal canal anatomy and effectively identifies the fistulae. For evidence-based care, a cost-effective and an accurate imaging modality is required in a developing country. Therefore, the aim of this study was to determine the diagnostic accuracy of short tau inversion recovery (STIR) as a limited protocol MRI pelvis in diagnosing perianal fistula taking surgical findings as the gold standard. Materials and methods A retrospective review of MRI pelvis from 1st February 2018 to 1st July 2018 was undertaken. Patients of any age or gender suspected to have perianal fistula were included. One radiologist interpreted the complete MRI pelvis and the other radiologist only viewed axial and coronal STIR sequences as a limited protocol. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of axial and coronal STIR sequence were calculated taking surgical findings as the gold standard. Results In total, 150 patients were included in this study. The mean age of the patients was 43.20 ± 13.75 years. In total, 122 (81.3%) were males and 28 (18.7%) were females. Using STIR as a limited protocol, fistulae were found in 125 (83.3%) patients, whereas on surgery, the fistulae were found in 119 (79.3%) patients. Sensitivity, specificity, PPV, NPV, and diagnostic accuracy of STIR as limited protocol MRI pelvis in diagnosing perianal fistulae was found to be 96.6%, 67.7%, 92.0%, 84.0%, and 90.6%, respectively, taking surgical findings as the gold standard. Conclusion STIR has high sensitivity and diagnostic accuracy in diagnosing in the perianal fistula. Using STIR as a limited protocol in a developing country can help improving patient care by accurately diagnosing perianal fistulae. Moreover, it is recommended that further studies for identifying internal opening on STIR should also be carried out to improve patient care.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...