Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Talanta ; 271: 125676, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38266436

RESUMEN

Cinnamon is one of the most popular spices used in cuisines worldwide. Among its different species, Ceylon cinnamon ("true cinnamon") is the one with the most health benefits due to its high concentration in the antioxidant eugenol and the ultra-low content of the hepatotoxic compound coumarin. However, the higher price of Ceylon cinnamon makes it vulnerable to fraudulent adulteration with more economic species of cinnamon, such as Cassia and Saigon. Thus, for the detection of frauds in cinnamon samples, a HPLC-UV method was developed for the determination of 4 characteristic cinnamon compounds: eugenol, cinnamaldehyde, coumarin and cinnamic acid. The obtained data were analyzed by PLS to attain not only the authentication of cinnamon species but also the detection and quantification of partial adulterations. Several mixtures prepared in the laboratory using different cinnamon powder samples considered 'pure' Ceylon, Cassia or Saigon were tested, concluding that the proposed approach allows a clear identification of Ceylon cinnamon and a suitable quantification of the Ceylon: non-Ceylon ratio regardless of the commercial sample selected (RMSE <0.06 for both training and test sets).


Asunto(s)
Cinnamomum zeylanicum , Eugenol , Cromatografía Líquida de Alta Presión/métodos , Quimiometría , Cumarinas/análisis
2.
Phys Chem Chem Phys ; 25(27): 17952-17965, 2023 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-37376995

RESUMEN

In recent years the use of partition systems other than the widely used biphasic n-octanol/water has received increased attention to gain insight into the molecular features that dictate the lipophilicity of compounds. Thus, the difference between n-octanol/water and toluene/water partition coefficients has proven to be a valuable descriptor to study the propensity of molecules to form intramolecular hydrogen bonds and exhibit chameleon-like properties that modulate solubility and permeability. In this context, this study reports the experimental toluene/water partition coefficients (log Ptol/w) for a series of 16 drugs that were selected as an external test set in the framework of the Statistical Assessment of the Modeling of Proteins and Ligands (SAMPL) blind challenge. This external set has been used by the computational community to calibrate their methods in the current edition (SAMPL9) of this contest. Furthermore, the study also investigates the performance of two computational strategies for the prediction of log Ptol/w. The first relies on the development of two machine learning (ML) models, which are built up by combining the selection of 11 molecular descriptors in conjunction with either the multiple linear regression (MLR) or the random forest regression (RFR) model to target a dataset of 252 experimental log Ptol/w values. The second consists of the parametrization of the IEF-PCM/MST continuum solvation model from B3LYP/6-31G(d) calculations to predict the solvation free energies of 163 compounds in toluene and benzene. The performance of the ML and IEF-PCM/MST models has been calibrated against external test sets, including the compounds that define the SAMPL9 log Ptol/w challenge. The results are used to discuss the merits and weaknesses of the two computational approaches.

3.
Pharmaceutics ; 14(11)2022 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-36365131

RESUMEN

The application of a computational screening methodology based on the calculation of intermolecular interaction energies has guided the discovery of new multicomponent solid forms of the oral antiviral Adefovir Dipivoxyl. Three new cocrystals with resorcinol, orcinol and hydroquinone have been synthesized and thoroughly characterized. They show improved dissolution profiles with respect to the single solid form, particularly the cocrystals of orcinol and resorcinol, which have 3.2- and 2-fold faster dissolution rates at stomach conditions (pH 1.5). Moreover, dynamic dissolution experiments that simultaneously mimic both the pH variation along the gastrointestinal tract and the partition into biological membranes show that, in addition to the faster initial dissolution, Adefovir Dipivoxyl also penetrates faster into the organic membranes in the form of resorcinol and orcinol cocrystals.

4.
Inorg Chem ; 61(41): 16256-16265, 2022 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-36007145

RESUMEN

Zn ions (Zn2+) play an important biological role in many diseases; hence, an imaging method for monitoring the Zn2+ distribution in tissues could provide important clinical insights. Recently, we reported a potent Zn-sensitive probe based on the Gd-DO3A (DO3A = 1,4,7,10-tetraazacyclododecane-1,4,7-tricarboxylic acid), modified tyrosine. and di(2-picolyl)amine chelator for this metal cation, which generates an outstanding magnetic resonance imaging (MRI) response. Here we further explored the origin of this unprecedented response and expanded the choice of potential MRI probes by preparing the free acid version of the initial MRI sensor. We report a detailed investigation of the 1H NMR dispersion, 17O NMR, and isothermal titration calorimetry properties of these two MRI probes upon interaction with Zn2+. The performed experiments confirm selective interaction of the MRI probes and target metal cation, which causes substantial changes in the coordination sphere of the paramagnetic center. It also evidenced some aggregation, which enhances the relaxivity response. Interestingly, conversion of the methyl ester to the free carboxylic acid of the tyrosine moiety changes the nature of the aggregates and leads to a smaller relaxivity response. The probes interact with human serum albumin (HSA) in the absence of Zn2+, which leads to a possible modification of the coordination sphere of Gd3+ or a substantial change in the exchange rate of second-sphere water molecules. In the presence of Zn2+, the interaction with HSA is very weak, demonstrating the importance of the Zn2+ coordination sphere in the behavior of these systems.


Asunto(s)
Gadolinio , Zinc , Aminas , Ácidos Carboxílicos , Quelantes/química , Medios de Contraste/química , Medios de Contraste/farmacología , Ésteres , Gadolinio/química , Humanos , Iones , Imagen por Resonancia Magnética/métodos , Albúmina Sérica Humana , Ácidos Tricarboxílicos , Tirosina , Agua/química , Zinc/química
5.
Talanta ; 241: 123273, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35123245

RESUMEN

A hybrid sensing system, which combines simultaneous cyclic voltammetric (CV) and UV-vis absorbance measurements using a commercial carbon screen-printed electrode and a set of optical fibres in disposable cuvettes, is proposed. The hybrid system approach was applied to 27 samples of recognized beer brands, improving the classification power as compared to only voltammetric or only spectrophotometric measurements. The developed partial least squares discriminant analysis (PLS-DA) model was able to discriminate between five types of beer (lager, marzen, black/stout, alcohol-free and white/ale). The model was also successfully applied to 28 beer samples of white-label brands sold in local supermarkets, demonstrating their similarity to recognized brand beers.


Asunto(s)
Cerveza , Etanol , Cerveza/análisis , Análisis Discriminante , Electrodos , Etanol/análisis , Análisis de los Mínimos Cuadrados
6.
Eur J Pharm Sci ; 168: 106066, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34767947

RESUMEN

A wide set of well-known drugs, most of them included in the Abraham´s reference database, covering a wide variety of chemical structures and therapeutical functionalities were chosen in order to determine some molecular properties from solvent/water partition measurements. Partition data from aqueous solutions and four different solvents (n-dodecane, toluene, chloroform and n-octanol) were measured and reported. From them, Abraham´s molecular descriptors of selected compounds (A, B and S, accounting for hydrogen bond donor, hydrogen bond acceptor and dipolarity/polaritzability, respectively) were estimated. A and B values derived from the experimental measurements strongly agree with the tabulated ones showing the suitability of the used procedure to achieve reliable values for new molecules. However, obtained S values differ from those previously reported for several compounds. Moreover, values for a new indicator of the propensity to form intramolecular hydrogen bonds (Δlog Poct-tol) were estimated from the experimental data and also calculated according to both, the Abraham´s model and the molecular structures (SMD). The quality of both series of calculated descriptors was evaluated by contrast with the experimental values and satisfactory results were obtained in both instances. Thus, the Abraham´s way is useful when molecular descriptors are available but very good estimations can be achieved by SMD, which only requires the drug´s molecular structure.


Asunto(s)
Preparaciones Farmacéuticas , Agua , 1-Octanol , Enlace de Hidrógeno , Solventes
7.
Talanta ; 238(Pt 2): 123036, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34801894

RESUMEN

The exceptional properties of 2D layered black phosphorus (BP) make it a promising candidate for electrochemical sensing applications and, even though BP is considered unstable and tends to degrade by the presence of oxygen and moisture, its oxidation can be beneficial in some situations. In this work, we present an unequivocal demonstration that the exposition of BP-based working electrodes to normal ambient conditions can indeed be advantageous, leading to an enhancement of voltammetric sensing applications. This point was proved using a BP modified screen-printed carbon electrode (BP-SPCE) for the voltammetric determination of dopamine (DA) as a model target analyte. Oxidized BP-SPCE (up to 35% of PxOy at the surface) presented an enhanced analytical performance with a 5-fold and 2-fold increase in sensitivity, as compared to bare-SPCE and non-oxidized BP-SPCE stored in anhydrous atmosphere, respectively. Good detection limit, repeatability, reproducibility, stability, selectivity, and accuracy were also achieved. Overall, the results presented herein display the prominent possibilities of preparing and working with BP based-sensors in normal ambient settings and showcase their implementation under physiological conditions.


Asunto(s)
Técnicas Electroquímicas , Fósforo , Carbono , Electrodos , Reproducibilidad de los Resultados
8.
ACS Sens ; 6(7): 2763-2771, 2021 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-34228919

RESUMEN

Wearable lactate sensors for sweat analysis are highly appealing for both the sports and healthcare fields. Electrochemical biosensing is the approach most widely used for lactate determination, and this technology generally demonstrates a linear range of response far below the expected lactate levels in sweat together with a high influence of pH and temperature. In this work, we present a novel analytical strategy based on the restriction of the lactate flux that reaches the enzyme lactate oxidase, which is immobilized in the biosensor core. This is accomplished by means of an outer plasticized polymeric layer containing the quaternary salt tetradodecylammonium tetrakis(4-chlorophenyl) borate (traditionally known as ETH500). Also, this layer prevents the enzyme from being in direct contact with the sample, and hence, any influence with the pH and temperature is dramatically reduced. An expanded limit of detection in the millimolar range (from 1 to 50 mM) is demonstrated with this new biosensor, in addition to an acceptable response time; appropriate repeatability, reproducibility, and reversibility (variations lower than 5% for the sensitivity); good resiliency; excellent selectivity; low drift; negligible influence of the flow rate; and extraordinary correlation (Pearson coefficient of 0.97) with a standardized method for lactate detection such as ion chromatography (through analysis of 22 sweat samples collected from 6 different subjects performing cycling or running). The developed lactate biosensor is suitable for on-body sweat lactate monitoring via a microfluidic epidermal patch additionally containing pH and temperature sensors. This applicability was demonstrated in three different body locations (forehead, thigh, and back) in a total of five on-body tests while cycling, achieving appropriate performance and validation. Moreover, the epidermal patch for lactate sensing is convenient for the analysis of sweat stimulated by iontophoresis in the subjects' arm, which is of great potential toward healthcare applications.


Asunto(s)
Técnicas Biosensibles , Sudor , Humanos , Ácido Láctico , Microfluídica , Reproducibilidad de los Resultados
9.
Mol Pharm ; 18(6): 2311-2321, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33983741

RESUMEN

It is widely accepted that solubility-pH profiles of ionizable compounds follow the Henderson-Hasselbalch equation. However, several studies point out that compounds often undergo additional processes in saturated solutions, such as sub-micellar oligomerization, micellar aggregation, or drug-buffer complexation among others, which make the experimental profiles deviate from the behavior predicted by the Henderson-Hasselbalch equation. Often, the presence of additional processes is supported by the analysis of experimental data through solubility computer programs. However, the purpose of this work is to experimentally prove the aggregation phenomena for a series of bases for which deviations from the theoretical profile have been observed. To this end, five monoprotic bases (lidocaine, maprotiline, cyproheptadine, bupivacaine, and mifepristone) susceptible to form ionic aggregates in solution have been selected, and mass spectrometry has been the technique of choice to prove the presence of aggregation. High declustering potentials have been applied to prevent aggregates from forming in the ionization source of the mass spectrometer. In addition, haloperidol has been used as a negative control since according to its profile, it is not suspected to form ionic aggregates. In all instances, except for haloperidol, the analysis of the saturated solutions revealed the presence of mixed-charged dimers (aggregates formed by a neutral molecule and a charged one) and even trimers in the case of mifepristone and bupivacaine. For lidocaine, the most soluble of the compounds, the presence of neutral aggregates was also detected. These experiments support the hypothesis that the simple Henderson-Hasselbalch equation may explain the solubility-pH behavior of certain compounds, but it can be somewhat inaccurate in describing the behavior of many other substances.


Asunto(s)
Iones/química , Soluciones/química , Química Farmacéutica , Concentración de Iones de Hidrógeno , Solubilidad , Espectrometría de Masas en Tándem
10.
Pharmaceuticals (Basel) ; 14(3)2021 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-33806467

RESUMEN

The interaction between drugs and transport proteins, such as albumins, is a key factor in drug bioavailability. One of the techniques commonly used for the evaluation of the drug-protein complex formation is fluorescence. This work studies the interaction of human serum albumin (HSA) with four non-steroidal anti-inflammatory drugs (NSAIDs)-ibuprofen, flurbiprofen, naproxen, and diflunisal-by monitoring the fluorescence quenching when the drug-albumin complex is formed. Two approaches-the double logarithm Stern-Volmer equation and the STAR program-are used to evaluate the binding parameters. The results are analyzed considering the binding properties, determined by using other complementary techniques and the available structural information of albumin complexes with NSAID-related compounds. Finally, this combined analysis has been synergistically used to interpret the binding of flurbiprofen to HSA.

11.
ACS Sens ; 6(3): 1129-1137, 2021 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-33566575

RESUMEN

We present herein the most complete characterization of microneedle (MN) potentiometric sensors for pH transdermal measurements for the time being. Initial in vitro assessment demonstrated suitable analytical performances (e.g., Nernstian slope, linear range of response from 8.5 to 5.0, and fast response time) in both buffer media and artificial interstitial fluid (ISF). Excellent repeatability and reproducibility together with adequate selectivity and resiliency facilitate the appropriateness of the new pH MN sensor for transdermal ISF analysis in healthcare. The ability to resist skin insertions was evaluated in several ex vivo setups using three different animal skins (i.e., chicken, pork, and rat). The developed pH MN sensor was able to withstand from 5 to 10 repetitive insertions in all the skins considered with a minimal change in the calibration graph (<3% variation in both slope and intercept after the insertions). Ex vivo pH measurements were validated by determining the pH with the MN sensor and a commercial pH electrode in chicken skin portions previously conditioned at several pH values, obtaining excellent results with an accuracy of <1% and a precision of <2% in all cases. Finally, pH MN sensors were applied for the very first time to transdermal measurements in rats together with two innovative validation procedures: (i) measuring subcutaneous pH directly with a commercial pH microelectrode and (ii) collecting ISF using hollow MNs and then the pH measurement of the sample with the pH microelectrode. The pH values obtained with pH MN sensors were statistically more similar to subcutaneous measurements, as inferred by a paired sample t-test at 95% of confidence level. Conveniently, the validation approaches could be translated to other analytes that are transdermally measured with MN sensors.


Asunto(s)
Técnicas Biosensibles , Animales , Electrodos , Concentración de Iones de Hidrógeno , Potenciometría , Ratas , Reproducibilidad de los Resultados
12.
Pharmaceutics ; 14(1)2021 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-35056945

RESUMEN

A new cocrystal of Norfloxacin, a poorly soluble fluoroquinolone antibiotic, has been synthetized by a solvent-mediated transformation experiment in toluene, using resorcinol as a coformer. The new cocrystal exists in both anhydrous and monohydrate forms with the same (1:1) Norfloxacin/resorcinol stoichiometry. The solubility of Norfloxacin and the hydrated cocrystal were determined by the shake-flask method. While Norfloxacin has a solubility of 0.32 ± 0.02 mg/mL, the cocrystal has a solubility of 2.64 ± 0.39 mg/mL, approximately 10-fold higher. The dissolution rate was tested at four biorelevant pH levels of the gastrointestinal tract: 2.0, 4.0, 5.5, and 7.4. In a first set of comparative tests, the dissolution rate of Norfloxacin and the cocrystal was determined separately at each pH value. Both solid forms showed the highest dissolution rate at pH 2.0, where Norfloxacin is totally protonated. Then, the dissolution rate decreases as pH increases. In a second set of experiments, the dissolution of the cocrystal was evaluated by a unique dissolution test, in which the pH dynamically changed from 2.0 to 7.4, stepping 30 min at each of the four biorelevant pH values. Results were quite different in this case, since dissolution at pH 2 affects the behavior of Norfloxacin at the rest of the pH values.

13.
J Solid State Electrochem ; 24(11-12): 2653-2661, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32837295

RESUMEN

A personal mini-review is presented on the history of electroanalysis and on their present achievements and future challenges. The manuscript is written from the subjective view of two generations of electroanalytical chemists that have witnessed for many years the evolution of this discipline.

14.
Sensors (Basel) ; 20(14)2020 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-32708149

RESUMEN

Glycine monitoring is gaining importance as a biomarker in clinical analysis due to its involvement in multiple physiological functions, which results in glycine being one of the most analyzed biomolecules for diagnostics. This growing demand requires faster and more reliable, while affordable, analytical methods that can replace the current gold standard for glycine detection, which is based on sample extraction with subsequent use of liquid chromatography or fluorometric kits for its quantification in centralized laboratories. This work discusses electrochemical sensors and biosensors as an alternative option, focusing on their potential application for glycine determination in blood, urine, and cerebrospinal fluid, the three most widely used matrices for glycine analysis with clinical meaning. For electrochemical sensors, voltammetry/amperometry is the preferred readout (10 of the 13 papers collected in this review) and metal-based redox mediator modification is the predominant approach for electrode fabrication (11 of the 13 papers). However, none of the reported electrochemical sensors fulfill the requirements for direct analysis of biological fluids, most of them lacking appropriate selectivity, linear range of response, and/or capability of measuring at physiological conditions. Enhanced selectivity has been recently reported using biosensors (with an enzyme element in the electrode design), although this is still a very incipient approach. Currently, despite the benefits of electrochemistry, only optical biosensors have been successfully reported for glycine detection and, from all the inspected works, it is clear that bioengineering efforts will play a key role in the embellishment of selectivity and storage stability of the sensing element in the sensor.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Electroquímica , Electrodos , Glicina , Metales
15.
Nanomaterials (Basel) ; 10(7)2020 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-32629854

RESUMEN

Carbon-nanofiber-based screen-printed electrodes modified with silver nanoparticles (Ag-NP-SPCNFEs) were tested in a pioneering manner for the direct determination of As(V) at low µg L-1 levels by means of differential pulse anodic stripping voltammetry. Screen-printed electrodes were modified with two different types of Ag-NPs, nanoseeds (NS), and nanoprisms (NPr) and characterized both microscopically and electrochemically. Furthermore, after optimizing the direct voltammetric determination of As(V), the analytical performance of considered sensors was compared for the direct determination of As(V). These results suggest that Ag-NS offer a better analytical response compared to Ag-NPr, with a detection and quantification limit of 0.6 and 1.9 µg L-1, respectively. The proposed methodology was validated using a spiked tap water sample with a very high reproducibility and good agreement with inductively coupled plasma - mass spectrometry (ICP-MS) measurements.

16.
Eur J Pharm Sci ; 148: 105305, 2020 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-32184154

RESUMEN

The solubility of three drugs (glimepiride, pioglitazone, sibutramine) with different acid/base properties and expected supersaturation behavior was examined in detail using the shake-flask (SF) and potentiometric (CheqSol) methods. Both uncharged (free) species and hydrochloride salts were used as starting materials. On the one hand, the SF method provided information about the thermodynamic solubility at any pH value, including the counterion-dependent solubility of ionic species. Additionally, this method easily allowed the identification of the solid phase in equilibrated solutions by powder X-ray diffraction, and the detection and quantification of aggregation and complexation reactions. On the other hand, CheqSol method permitted the measurement of the equilibrium solubility of neutral species, the observation of changes in solid forms, and the extent and duration of supersaturation (kinetic solubility) for "chaser" compounds. The combined information from both methods gave an accurate picture of the solubility behavior of the studied drugs.


Asunto(s)
Preparaciones Farmacéuticas/química , Tecnología Farmacéutica/métodos , Ciclobutanos/química , Concentración de Iones de Hidrógeno/efectos de los fármacos , Pioglitazona/química , Potenciometría/métodos , Solubilidad , Compuestos de Sulfonilurea/química
17.
Anal Chem ; 92(4): 3396-3402, 2020 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-31951120

RESUMEN

A multivariate version of the classical univariate standard addition method is proposed for the analysis of samples generating overlapping signals in the presence of notorious matrix effects. Unlike previous versions based on multivariate calibration by partial least-squares (PLS), the proposed strategy takes advantage of a self-modeling methodology: multivariate curve resolution by alternating least-squares (MCR-ALS) enhanced with signal shape constraints based on parametric functions. In this way, there is no need for the full multivariate response of a blank solution, and in multianalyte determinations, the standard additions can be made with a solution containing all of the analytes, which constitutes a clear advance as compared to PLS approach. The proposed method has been successfully tested in the voltammetric determination of hydroquinone and catechol in solutions of increasing complexity and appears to be a promising tool in the field of electroanalysis.

18.
J Comput Aided Mol Des ; 34(4): 443-451, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31776809

RESUMEN

The IEFPCM/MST continuum solvation model is used for the blind prediction of n-octanol/water partition of a set of 11 fragment-like small molecules within the SAMPL6 Part II Partition Coefficient Challenge. The partition coefficient of the neutral species (log P) was determined using an extended parametrization of the B3LYP/6-31G(d) version of the Miertus-Scrocco-Tomasi continuum solvation model in n-octanol. Comparison with the experimental data provided for partition coefficients yielded a root-mean square error (rmse) of 0.78 (log P units), which agrees with the accuracy reported for our method (rmse = 0.80) for nitrogen-containing heterocyclic compounds. Out of the 91 sets of log P values submitted by the participants, our submission is within those with an rmse < 1 and among the four best ranked physical methods. The largest errors involve three compounds: two with the largest positive deviations (SM13 and SM08), and one with the largest negative deviations (SM15). Here we report the potentiometric determination of the log P for SM13, leading to a value of 3.62 ± 0.02, which is in better agreement with most empirical predictions than the experimental value reported in SAMPL6. In addition, further inclusion of several conformations for SM08 significantly improved our results. Inclusion of these refinements led to an overall error of 0.51 (log P units), which supports the reliability of the IEFPCM/MST model for predicting the partitioning of neutral compounds.


Asunto(s)
Octanoles/química , Termodinámica , Agua/química , Simulación por Computador , Compuestos Heterocíclicos/química , Conformación Molecular , Teoría Cuántica , Solventes/química
19.
Sensors (Basel) ; 19(19)2019 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-31575062

RESUMEN

A critical revision is made on recent applications of voltammetric electronic tongues in the field of food analysis. Relevant works are discussed dealing with the discrimination of food samples of different type, origin, age and quality and with the prediction of the concentration of key substances and significant indexes related to food quality.

20.
Talanta ; 201: 104-110, 2019 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-31122399

RESUMEN

A simple HPLC-EC method based on hydrophilic interaction liquid chromatography with amperometric detection through gold screen-printed electrodes has been developed and applied for the first time to the determination of aminothiols in white wines. Moreover, the coupling of the method with partial least squares discriminant analysis (PLS-DA) using the analysed aminothiols as biomarkers provides wine discrimination in terms of harvest year. White wine samples were directly injected and chromatographic areas, together with pH and redox potential values, allowed a successful discrimination of wines from different harvest years with a global classification rate of 97.8%. The developed HPLC-EC method also generated characteristic fingerprints that were combined with PLS-DA to classify wines according to three wine varieties, with a global classification rate of 95.3%.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...