Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
World J Radiol ; 4(6): 258-64, 2012 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-22778878

RESUMEN

AIM: To evaluate safety and utility of coronary computed tomography angiography (CCTA) compared to invasive coronary angiography (ICA) in new cardiomyopathy. METHODS: Eighteen patients (mean age 56.5 years, 10 males) who presented for evaluation of new onset heart failure with evidence of systolic dysfunction (ejection fraction < 40%) on echocardiography and recent ICA were prospectively enrolled. Patients with known coronary artery disease, atrial fibrillation, creatinine > 1.5 g/dL, and contraindication to intravenous contrast administration were excluded. CCTA was performed using a dual source 64-slice scanner. Mean heart rate was 75 beats per minute. Stenosis was graded for each coronary segment as: none, mild (< 50%), moderate (50%-70%), severe (> 70%), or non-evaluable. Ischemic cardiomyopathy (ICM) was diagnosed if severe stenosis was present in the left main, proximal left anterior descending artery, or two or more major arteries. RESULTS: Two patients were diagnosed with ICM by ICA. CCTA correctly identified 2 patients with ICM and 16 patients as non-ICM. CCTA successfully evaluated 240/246 coronary segments with an accuracy of 97.5%, sensitivity 70%, specificity 98.7%, positive predictive value of 70%, and negative predictive value of 98.7% for identifying severe stenosis on a per-segment level. CONCLUSION: Dual source 64-slice multi-detector CCTA is a safe, accurate, and non-invasive technique for diagnosing ICM in patients presenting during the acute phase of newly diagnosed cardiomyopathy.

4.
Biophys J ; 84(1): 599-611, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12524313

RESUMEN

Hydrodynamic properties as well as structural dynamics of proteins can be investigated by the well-established experimental method of fluorescence anisotropy decay. Successful use of this method depends on determination of the correct kinetic model, the extent of cross-correlation between parameters in the fitting function, and differences between the timescales of the depolarizing motions and the fluorophore's fluorescence lifetime. We have tested the utility of an independently measured steady-state anisotropy value as a constraint during data analysis to reduce parameter cross correlation and to increase the timescales over which anisotropy decay parameters can be recovered accurately for two calcium-binding proteins. Mutant rat F102W parvalbumin was used as a model system because its single tryptophan residue exhibits monoexponential fluorescence intensity and anisotropy decay kinetics. Cod parvalbumin, a protein with a single tryptophan residue that exhibits multiexponential fluorescence decay kinetics, was also examined as a more complex model. Anisotropy decays were measured for both proteins as a function of solution viscosity to vary hydrodynamic parameters. The use of the steady-state anisotropy as a constraint significantly improved the precision and accuracy of recovered parameters for both proteins, particularly for viscosities at which the protein's rotational correlation time was much longer than the fluorescence lifetime. Thus, basic hydrodynamic properties of larger biomolecules can now be determined with more precision and accuracy by fluorescence anisotropy decay.


Asunto(s)
Polarización de Fluorescencia/métodos , Modelos Moleculares , Parvalbúminas/química , Parvalbúminas/efectos de la radiación , Agua/química , Animales , Anisotropía , Peces/metabolismo , Luz , Movimiento (Física) , Parvalbúminas/clasificación , Conformación Proteica , Proteínas/química , Control de Calidad , Ratas , Ratas Mutantes , Reproducibilidad de los Resultados , Reología/métodos , Rotación , Sensibilidad y Especificidad , Soluciones/química , Especificidad de la Especie , Triptófano/química , Viscosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...