Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 10(1): 6783, 2020 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-32321969

RESUMEN

Field of generating a surface thin film is emerging broadly in sensing applications to obtain the quick and fast results by forming the high-performance sensors. Incorporation of thin film technologies in sensor development for the better sensing could be a promising way to attain the current requirements. This work predominantly delineates the fabrication of the dielectric sensor using two different sensing materials (Gold and Aluminium). Conventional photolithography was carried out using silicon as a base material and the photo mask of the dielectric sensor was designed by AutoCAD software. The physical characterization of the fabricated sensor was done by Scanning Electron Microscope, Atomic Force Microscope, High Power Microscope and 3D-nano profiler. The electrical characterization was performed using Keithley 6487 picoammeter with a linear sweep voltage of 0 to 2 V at 0.01 V step voltage. By pH scouting, I-V measurements on the bare sensor were carried out, whereby the gold electrodes conducts a least current than aluminium dielectrodes. Comparative analysis with pH scouting reveals that gold electrode is suitable under varied ionic strengths and background electrolytes, whereas aluminium electrodes were affected by the extreme acid (pH 1) and alkali (pH 12) solutions.

2.
Mikrochim Acta ; 186(6): 336, 2019 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-31069542

RESUMEN

A gene sensor for rapid detection of the Human Papillomavirus 16 (HPV 16) which is associated with the appearance of cervical cancer was developed. The assay is based on voltammetric determination of HPV 16 DNA by using interdigitated electrodes modified with titanium dioxide nanoparticles. Titanium dioxide nanoparticles (NPs) were used to modify a semiconductor-based interdigitated electrode (IDE). The surface of the NPs was then functionalized with a commercial 24-mer oligomer DNA probe for HPV 16 that was modified at the 5' end with a carboxyl group. If the probe interacts with the HPV 16 ssDNA, the current, best measured at a working voltage of 1.0 V, increases. The gene sensor has has a ∼ 0.1 fM limit of detection which is comparable to other sensors. The dielectric voltammetry analysis was carried out from 0 V to 1 V. The electrochemical sensitivity of the IDE is 2.5 × 10-5 µA·µM-1·cm-2. Graphical abstract Schematic of an interdigitated electrode (IDE) modified with titanium dioxide nanoparticles for voltammetric determination of HPV 16 DNA by using an appropriate DNA probe.


Asunto(s)
Técnicas Biosensibles/métodos , ADN Viral/análisis , Técnicas Electroquímicas/métodos , Papillomavirus Humano 16/química , Nanopartículas del Metal/química , Titanio/química , Sondas de ADN/química , Sondas de ADN/genética , ADN Viral/genética , Técnicas Electroquímicas/instrumentación , Electrodos , Femenino , Humanos , Límite de Detección , Hibridación de Ácido Nucleico , Prueba de Estudio Conceptual , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...