Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Sci Rep ; 13(1): 19172, 2023 11 06.
Artículo en Inglés | MEDLINE | ID: mdl-37932407

RESUMEN

YKL-40 increase according to the aging process, and its functions have been associated with tissue remodeling and systemic inflammation. In Rheumatoid Arthritis (RA) it has been proposed as a possible biomarker of activity and severity, however; in the field of idiopathic inflammatory myopathies (IIM) the role of YKL-40 in IIM is not clear. Thus, we aimed to evaluate if there is an association between the serum levels and muscle tissue expression of YKL-40 with age, IIM phenotype, muscle strength and myositis disease activity. The main finding was that age is the most important variable that affects the YKL-40 serum levels. In muscle biopsy, we observed that YKL-40 is mainly expressed in infiltrating lymphoid cells than in muscle tissue. Using ANCOVA according to the b-coefficients, YKL-40 serum levels are predicted by inflammatory state, age, and IIM diagnosis.


Asunto(s)
Artritis Reumatoide , Miositis , Humanos , Proteína 1 Similar a Quitinasa-3 , Miositis/diagnóstico , Artritis Reumatoide/complicaciones , Biomarcadores , Músculos/patología
2.
BMC Cardiovasc Disord ; 20(1): 440, 2020 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-33028211

RESUMEN

BACKGROUND: Human immunodeficiency virus (HIV) infection is associated with a greater risk of cardiovascular disease (CVD). HIV infection causes a chronic inflammatory state and increases oxidative stress which can cause endothelial dysfunction and arterial stiffness. Aortic stiffness measured by carotid femoral-pulse wave velocity (cfPWV) and central hemodynamics are independent cardiovascular risk factors and have the prognostic ability for CVD. We assessed cfPWV and central hemodynamics in young individuals with recent HIV infection diagnosis and without antiretroviral therapy. We hypothesized that individuals living with HIV would present greater cfPWV and central hemodynamics (central systolic blood pressure and pulse pressure) compared to uninfected controls. METHODS: We recruited 51 treatment-naïve individuals living with HIV (HIV(+)) without previous CVD and 51 age- and sex-matched controls (HIV negative (-)). We evaluated traditional CVD risk factors including metabolic profile, blood pressure (BP), smoking, HIV viral load, and CD4+ T-cells count. Arterial stiffness and central hemodynamics were evaluated by cfPWV, central systolic BP, and central pulse pressure (cPP) via applanation tonometry. RESULTS: HIV(+) individuals presented a greater prevalence of smoking, reduced high-density lipoprotein cholesterol, and body mass index. 65.9% of HIV(+) individuals exhibited lymphocyte CD4+ T-cells count < 500 cells/µL. There was no difference in brachial or central BP between groups; however, HIV(+) individuals showed significantly lower cPP. We observed a greater cfPWV (mean difference = 0.5 m/s; p < 0.01) in HIV(+) compared to controls, even after adjusting for heart rate, mean arterial pressure and smoking. CONCLUSION: In the early stages of infection, non-treated HIV individuals present a greater prevalence of traditional CVD risk factors, arterial stiffness, and normal or in some cases central hemodynamics.


Asunto(s)
Enfermedades Cardiovasculares/epidemiología , Infecciones por VIH/epidemiología , Hemodinámica , Rigidez Vascular , Adulto , Presión Sanguínea , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/fisiopatología , Velocidad de la Onda del Pulso Carotídeo-Femoral , Estudios de Casos y Controles , Estudios Transversales , Femenino , Infecciones por VIH/diagnóstico , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Masculino , Manometría , México/epidemiología , Prevalencia , Medición de Riesgo , Adulto Joven
3.
J Hypertens ; 38(4): 701-715, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31834122

RESUMEN

OBJECTIVE: In this analysis of the telehealth-based Vascular health ASsessment Of The hypertENSive patients Registry, we checked how 24-h central and peripheral hemodynamics compare with hypertension-mediated organ damage (HMOD). METHODS: In 646 hypertensive patients (mean age 52 ±â€Š16 years, 54% males, 65% treated) we obtained ambulatory brachial and central SBP and pulse pressure (PP), SBP, and PP variability, pulse wave velocity and augmentation index with a validated cuff-based technology. HMOD was defined by an increased left ventricular mass index (cardiac damage, evaluated in 482 patients), an increased intima-media thickness (vascular damage, n = 368), or a decreased estimated glomerular filtration rate or increased urine albumin excretion (renal damage, n = 388). RESULTS: Ambulatory SBP and PPs were significantly associated with cardiac damage: the largest odds ratio was observed for 24-h central SBP [1.032 (1.012, 1.051), P = 0.001] and PP [1.042 (1.015, 1.069), P = 0.002], the weakest for brachial estimates. The association was less strong for vascular damage with a trend to the superiority of 24-h central [1.036 (0.997, 1.076), P = 0.070] over brachial PP [1.031 (1.000, 1.062), P = 0.052]. No statistically significant association was observed for renal damage. SBP and PP variabilities, pulse wave velocity and augmentation index were not associated with any form of HMOD. In the multivariate analysis, age was associated with any type of HMOD, whereas central SBP and PP were predictive of an increased risk of cardiac damage. CONCLUSION: In hypertensive patients a variable association exists between peripheral and central hemodynamics and various types of HMOD, with the most predictive power being observed for central SBP and PP for cardiac damage.


Asunto(s)
Presión Sanguínea/fisiología , Hipertensión/fisiopatología , Riñón/fisiopatología , Adulto , Anciano , Determinación de la Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial , Grosor Intima-Media Carotídeo , Femenino , Tasa de Filtración Glomerular/fisiología , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Análisis de la Onda del Pulso , Sistema de Registros
4.
Int J Food Sci Nutr ; 70(8): 977-985, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31084381

RESUMEN

Type 2 diabetes mellitus (T2DM) is associated with premature atherosclerosis and arterial stiffening due to the accumulation of advanced glycation end-products in vessel walls. Green tea polyphenols are considered cardio-protective substances. In this randomised double-blind placebo-controlled trial (NCT02627898), we evaluated the effect of Green tea extract on arterial stiffness parameters, lipids, body composition and sRAGE levels. Twenty normotensive patients with T2DM treated with the standard therapy and statins, mean age 53.2 ± 9.4 years and mean BMI 30.1 ± 4.5 kg/m2, were randomised to receive a daily dose of 400 mg of green tea extract (polyphenols ≥90%, EGCG ≥45%) or placebo for 12 weeks. Compared to placebo, administration of green tea extract decreased central augmentation index (-3.05 ± 10.8% vs. 6.7 ± 0.1%, p = .04). These findings suggest that green tea extract could be used as an adjunct to the standard therapy to improve arterial stiffness in T2DM.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Metabolismo de los Lípidos/efectos de los fármacos , Extractos Vegetales/farmacología , Té/química , Rigidez Vascular/efectos de los fármacos , Adulto , Alanina Transaminasa/sangre , Aspartato Aminotransferasas/sangre , Composición Corporal/efectos de los fármacos , Índice de Masa Corporal , Colesterol/sangre , HDL-Colesterol/sangre , LDL-Colesterol/sangre , Creatinina/sangre , Diabetes Mellitus Tipo 2/sangre , Suplementos Dietéticos , Método Doble Ciego , Femenino , Hemoglobina Glucada/metabolismo , Hemodinámica/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Polifenoles/administración & dosificación , Receptor para Productos Finales de Glicación Avanzada/sangre , Proteínas S100/sangre , Triglicéridos/sangre
5.
Front Med (Lausanne) ; 6: 341, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32118001

RESUMEN

Introduction: Cardiovascular parameters disruption can be found in patients at early stages of rheumatoid arthritis (RA). The primary endpoint of this study was the reduction of arterial stiffness in RA patients without traditional cardiovascular risk factors or previous comorbidities, measured by cardio-ankle vascular index (CAVI) through the enalapril intervention. The secondary endpoints were the enalapril influence on carotid femoral pulse wave velocity (cfPWV), carotid intima media thickness (cIMT), carotid artery distensibility (cDistensibility), Young's incremental elastic modulus (Einc)]. Materials and Methods: Fifty-three patients were enrolled in a clinical, randomized, closed-label trial. The subjects were randomly assigned into two groups: One receiving 5 mg of enalapril (27) or placebo (26), both twice a day. The drug was acquired at Victory Enterprises®. The placebo was kindly provided by the Universidad de Guadalajara (UdeG), as well as the blinding into two groups: A and B. Enalapril and placebo were packed into bottles without labeling. Clinical assessment included a structured questionnaire to gather demographic and clinical variables as well as determination of CAVI, cfPWV, cIMT, carotid artery distensibility and Einc. The whole set of evaluations were analyzed at the baseline and at the end of 12 weeks of intervention. Results: The CAVI measurement at baseline was 7.1 ± 1.4 and increased up to 7.5 ± 1.2 at the end of 12 weeks. Meanwhile, the enalapril group was as follows: 7.4 ± 1.2 and at the of intervention, reduced to 7.1 ± 0.9. A reduction in delta CAVI of 0.21 in the enalapril intervention group was found. In contrast, an increase of 0.39 was observed in the placebo group. The delta CAVI reduction was not influenced by age or peripheral systolic blood pressure (pSBP). Discussion: Enalapril seems to be effective in CAVI reduction in RA patients. The effect of enalapril intervention on arterial stiffness translated to the clinical context might be interpreted as a reduction of 6.4 years of arterial aging. Trial Registration: The protocol was approved by the Institutional Review Board with the register CI-0117 from UdeG, and 0211/18 from Hospital Civil "Dr. Juan I. Menchaca", Secretaría de Salud Jalisco: DGSP/DDI/D.INV.28/18 and retrospectively registered at ClinicalTrials.gov Protocol Registration and Results System: NCT03667131.

7.
Rev Med Chil ; 146(2): 190-195, 2018 Feb.
Artículo en Español | MEDLINE | ID: mdl-29999155

RESUMEN

Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. AIM: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. MATERIAL AND METHODS: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). RESULTS: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was -0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and -0.9 mmHg (95% CI -1.7 to -0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. CONCLUSIONS: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea , Hipertensión/diagnóstico , Determinación de la Presión Sanguínea/métodos , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
8.
Rev. méd. Chile ; 146(2): 190-195, feb. 2018. tab, graf
Artículo en Español | LILACS | ID: biblio-961377

RESUMEN

Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. Aim: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. Material and Methods: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). Results: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was −0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and −0.9 mmHg (95% CI −1.7 to −0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. Conclusions: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea , Hipertensión/diagnóstico , Determinación de la Presión Sanguínea/métodos , Estudios Transversales , Reproducibilidad de los Resultados
9.
Blood Press Monit ; 22(6): 375-378, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28945665

RESUMEN

OBJECTIVE: The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. PARTICIPANTS AND METHODS: The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97-190), diastolic BP was 90.9±12.9 mmHg (range: 68-120), and arm circumference was 30.8±4 cm (range: 25-38.5). RESULTS: The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Presión Sanguínea , Esfigmomanometros/normas , Adulto , Anciano , Instituciones de Atención Ambulatoria , Brazo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Autocuidado/instrumentación
10.
Eur Heart J ; 34(10): 759-66, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22711752

RESUMEN

AIMS: We assessed the haemodynamic changes induced by exposure to high altitude hypoxia and the effects on them of acetazolamide, a drug prescribed to prevent and treat mountain sickness. METHODS AND RESULTS: In 42 subjects (21 males, age 36.8 ± 8.9 years) randomized to double blind acetazolamide 250 mg b.i.d. or placebo, pulse wave velocity and pulse wave parameters were assessed (PulsePen) at baseline; after 2-day treatment at sea level; within 6 h and on 3rd day of exposure to high altitude. Exposure to high altitude significantly increased diastolic (P < 0.005) and mean blood pressure (BP) (P < 0.05, after prolonged exposure) in placebo but not in the acetazolamide group. Therefore, subjects on acetazolamide showed significantly lower values of diastolic (P < 0.005) and mean BP (P < 0.05) at altitude. Furthermore, they also showed significantly lower values of systolic BP (P < 0.05). Pulse wave velocity did not change at high altitude, while the augmentation index, normalized for a theoretical heart rate of 75 b.p.m., significantly increased (P < 0.05) under placebo, but not under acetazolamide. In a multivariate model, unadjusted augmentation index at high altitude was not affected by BP changes, while significant determinants were heart rate and gender. CONCLUSION: Acute exposure to high altitude induced a rise in brachial BP and changes in pulse waveform-derived parameters, independent from changes in mean BP and partly counteracted by treatment with acetazolamide. The impact of acetazolamide on the haemodynamic alterations induced by hypobaric hypoxia may be considered among the beneficial effects of this drug in subjects prone to mountain sickness. CLINICAL TRIAL REGISTRATION: EudraCT Number: 2010-019986-27.


Asunto(s)
Acetazolamida/farmacología , Altitud , Presión Sanguínea/efectos de los fármacos , Inhibidores de Anhidrasa Carbónica/farmacología , Hipoxia/fisiopatología , Rigidez Vascular/efectos de los fármacos , Adulto , Mal de Altura/fisiopatología , Velocidad del Flujo Sanguíneo/efectos de los fármacos , Arteria Braquial/fisiología , Arteria Carótida Común/fisiología , Método Doble Ciego , Femenino , Humanos , Masculino , Oxígeno/sangre , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA