Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 92(3): 466-476, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29314563

RESUMEN

OBJECTIVES: To evaluate the outcomes of subadventitial stenting (SS) around occluded stents for recanalizing in-stent chronic total occlusions (IS-CTOs). BACKGROUND: There is little evidence on the outcomes of SS for IS-CTO. METHODS: We examined the outcomes of SS for IS-CTO PCI at 14 centers between July 2011 and June 2017, and compared them to historical controls recanalized using within-stent stenting (WSS). Target-vessel failure (TVF) on follow-up was the endpoint of this study, and was defined as a composite of cardiac death, target-vessel myocardial infarction, and target-vessel revascularization. RESULTS: During study period, 422 IS-CTO PCIs were performed, of which 32 (7.6%) were recanalized with SS, usually when conventional approaches failed. The most frequent CTO vessel was the right coronary artery (72%). Mean J-CTO score was 3.1 ± 0.9. SS was antegrade in 53%, and retrograde in 47%. Part of the occluded stent was crushed in 37%, while the whole stent was crushed in 63%. Intravascular imaging was used in 59%. One patient (3.1%) suffered tamponade. Angiographic follow-up was performed in 10/32 patients: stents were patent in six cases, one had mild neointimal hyperplasia, and three had severe restenosis at the SS site. Clinical follow-up was available for 29/32 patients for a mean of 388 ± 303 days. The 24-month incidence of TVF was 13.8%, which was similar to historical controls treated with WSS (19.5%, P = 0.49). CONCLUSIONS: SS is rarely performed, usually as last resort, to recanalize complex IS-CTOs. It is associated with favorable acute and mid-term outcomes, but given the small sample size of our study additional research is warranted.


Asunto(s)
Oclusión Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Anciano , Australia , Canadá , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Sistema de Registros , Retratamiento , Estudios Retrospectivos , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Ultrasonografía Intervencional , Estados Unidos , Grado de Desobstrucción Vascular
2.
Int J Cardiovasc Imaging ; 33(6): 771-778, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28120155

RESUMEN

Objectives The aim of this study was to quantify the radiation dose reduction during coronary angiography and percutaneous coronary intervention (PCI) through removal of the anti-scatter grid (ASG), and to assess its impact on image quality in adult patients with a low body mass index (BMI). Methods A phantom with different thicknesses of acrylic was used with a Westmead Test Object to simulate patient sizes and assess image quality. 129 low BMI patients underwent coronary angiography or PCI with or without the ASG in situ. Radiation dose was compared between both patient groups. Results With the same imaging system and a comparable patient population, ASG removal was associated with a 47% reduction in total dose-area product (DAP) (p < 0.001). Peak skin dose was reduced by 54% (p < 0.001). Operator scatter was reduced to a similar degree and was significantly reduced through removal of the ASG. Using an image quality phantom it was demonstrated that image quality remained satisfactory. Conclusions Removal of the ASG is a simple and effective method to significantly reduce radiation dose in coronary angiography and PCI. This was achieved while maintaining adequate diagnostic image quality. Selective removal of the ASG is likely to improve the radiation safety of cardiac angiography and interventions.


Asunto(s)
Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Exposición Profesional/prevención & control , Dosis de Radiación , Exposición a la Radiación/prevención & control , Radiografía Intervencional/instrumentación , Dispersión de Radiación , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Angiografía Coronaria/efectos adversos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Exposición Profesional/efectos adversos , Seguridad del Paciente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Fantasmas de Imagen , Proyectos Piloto , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos , Radiografía Intervencional/efectos adversos , Factores de Riesgo , Stents
3.
EuroIntervention ; 12(8): e939-e947, 2016 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-27721210

RESUMEN

AIMS: The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. METHODS AND RESULTS: Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. CONCLUSIONS: Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.


Asunto(s)
Cateterismo Cardíaco/métodos , Angiografía Coronaria/métodos , Fluoroscopía/métodos , Intervención Coronaria Percutánea/métodos , Dosis de Radiación , Exposición a la Radiación/prevención & control , Monitoreo de Radiación/métodos , Piel , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Puente de Arteria Coronaria , Femenino , Arteria Femoral , Reserva del Flujo Fraccional Miocárdico , Humanos , Análisis de Series de Tiempo Interrumpido , Modelos Lineales , Masculino , Persona de Mediana Edad , Tempo Operativo , Arteria Radial , Monitoreo de Radiación/instrumentación
4.
Pacing Clin Electrophysiol ; 28(8): 867-9, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16105017

RESUMEN

The finding of complete occlusion of the superior venal cava during the performance of cardiac pacing is rare. We report a case where performance of angioplasty aided the successful completion of permanent pacemaker implantation.


Asunto(s)
Angioplastia , Aleteo Atrial/terapia , Marcapaso Artificial , Síndrome de la Vena Cava Superior/terapia , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Síndrome de la Vena Cava Superior/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...