Biomedicines ; 9(11)2021 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-34829927

RESUMEN

(1) Background: Calcinosis cutis is a frequent symptom of autoimmune connective tissue diseases leading to pain, transcutaneous expulsion of calcified material and bacterial superinfection. There is a high need for new therapeutic options as no standardized treatment algorithm is established. While case reports indicate beneficial effects of bisphosphonates, standardized evaluation of treatment effects is missing. (2) Methods: In this retrospective analysis we evaluate the effects of intravenous pamidronate, a second-generation bisphosphonate, in seven patients with calcinosis cutis using consecutive clinical pictures, radiological examinations and patient's subjective evaluation. (3) Results: 5/6 patients reported a reduction of pain, improvement of general condition and cessation of calcinosis progression. Regression of skin lesions was detectable in clinical pictures of 2/6 patients, while 1/6 patients had stable disease. Radiological examination revealed improvement or stable disease in 3/5 patients. Fever was the most common side effect. One out of seven patients developed osteonecrosis of the jaw. (4) Conclusions: Bisphosphonates appear to have beneficial effects in a subgroup of calcinosis cutis patients. While patient's subjective evaluation was mainly positive, objective assessments showed improvement in approximately half of the cases. With regard to potential severe side effects, a careful risk-benefit evaluation is necessary before treatment initiation.

2.
J Ophthalmol ; 2019: 7813482, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31482038

RESUMEN

PURPOSE: Incorrect anterior-posterior orientation of the Descemet endothelial complex (DEC) is one of the causes of failure of Descemet membrane endothelial keratoplasty (DMEK). We evaluated a new marking technique to avoid such a misorientation. METHOD: A new marking technique of the DEC was evaluated in patients requiring primary DMEK. A Braille-"R"-letter was applied dot by dot onto the stromal surface of the DEC after lifting it by injecting an air-bubble into the interface between the endothelial surface of the partially stripped graft. The positioning of the graft was intraoperatively controlled by an orientation of the Braille-"R"-letter. Laboratory tests were conducted to test the impact of the marking technique on endothelial cell count. RESULTS: We included prospectively 37 eyes of 30 patients. Four eyes were phakic and 33 pseudophakic. Five grafts (14%) presented an undifferentiated rolling tendency in the anterior chamber, and evaluation of their positioning was possible due to orientation of the mark alone. In case of an upside-down orientation, grafts were flipped immediately. A correct orientation of the graft was achieved in all cases at the end of the surgery. The endothelial cell loss due to the mark was estimated to be less than 0.3%. At 3- and 6-month follow-ups, the mean best-corrected visual acuity was 0.21 ± 0.15 and 0.15 ± 0.11 logMAR, respectively, and endothelial cell density was 1661 ± 349 and 1618 ± 396 cells/mm2, respectively. Only one patient (3%) needed re-bubbling. CONCLUSIONS: To rely on the natural rolling tendency of the graft alone does not assure its correct positioning in all cases. Creation of the mark with 4 dots punctuated on the air-lifted stromal side of the DEC is a simple and endothelial cell saving marking method to ensure correct orientation of the graft during DMEK.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...