RESUMEN
The combination of high-end cryogenic transmission electron microscopes (cryo-EM), direct electron detectors, and advanced image algorithms allows researchers to obtain the 3D structures of much smaller macromolecules than years ago. However, there are still major challenges for the single-particle cryo-EM method to achieve routine structure determinations for macromolecules much smaller than 100 kDa, which are the majority of all plant and animal proteins. These challenges include sample characteristics such as sample heterogeneity, beam damage, ice layer thickness, stability, and quality, as well as hardware limitations such as detector performance, beam, and phase plate quality. Here, single particle data sets were simulated for samples that were ideal in terms of homogeneity, distribution, and stability, but with realistic parameters for ice layer, dose, detector performance, and beam characteristics. Reference data were calculated for human apo-ferritin using identical parameters reported for an experimental data set downloaded from EMPIAR. Processing of the simulated data set resulted in a value of 1.86 Å from 20â¯214 particles, similar to a 2 Å density map obtained from 29â¯224 particles selected from real micrographs. Simulated data sets were then generated for a 14 kDa protein, hen egg white lysozyme (HEWL), with and without an ideal phase plate (PP). Whereas we could not obtain a high-resolution 3D reconstruction of HEWL for the data set without PP, the one with PP resulted in a 2.78 Å resolution density map from 225â¯751 particles. Our simulator and simulations could help in pushing the size limits of cryo-EM.
Asunto(s)
Clara de Huevo , Muramidasa , Algoritmos , Animales , Microscopía por Crioelectrón , Humanos , Sustancias MacromolecularesRESUMEN
Correlative light and electron microscopy is an increasingly popular technique to study complex biological systems at various levels of resolution. Fluorescence microscopy can be employed to scan large areas to localize regions of interest which are then analyzed by electron microscopy to obtain morphological and structural information from a selected field of view at nm-scale resolution. Previously, an integrated approach to room temperature correlative microscopy was described. Combined use of light and electron microscopy within one instrument greatly simplifies sample handling, avoids cumbersome experimental overheads, simplifies navigation between the two modalities, and improves the success rate of image correlation. Here, an integrated approach for correlative microscopy under cryogenic conditions is presented. Its advantages over the room temperature approach include safeguarding the native hydrated state of the biological specimen, preservation of the fluorescence signal without risk of quenching due to heavy atom stains, and reduced photo bleaching. The potential of cryo integrated light and electron microscopy is demonstrated for the detection of viable bacteria, the study of in vitro polymerized microtubules, the localization of mitochondria in mouse embryonic fibroblasts, and for a search into virus-induced intracellular membrane modifications within mammalian cells.
Asunto(s)
Microscopía por Crioelectrón/métodos , Congelación , Microscopía Electrónica/métodos , Manejo de Especímenes/métodos , Acinetobacter baumannii , Animales , Chlorocebus aethiops , Fluorescencia , Microscopía Fluorescente , Microtúbulos , Células VeroRESUMEN
Charge-coupled devices (CCD) are nowadays commonly utilized in transmission electron microscopy (TEM) for applications in life sciences. Direct access to digitized images has revolutionized the use of electron microscopy, sparking developments such as automated collection of tomographic data, focal series, random conical tilt pairs and ultralarge single-particle data sets. Nevertheless, for ultrahigh-resolution work photographic plates are often still preferred. In the ideal case, the quality of the recorded image of a vitrified biological sample would solely be determined by the counting statistics of the limited electron dose the sample can withstand before beam-induced alterations dominate. Unfortunately, the image is degraded by the non-ideal point-spread function of the detector, as a result of a scintillator coupled by fibre optics to a CCD, and the addition of several inherent noise components. Different detector manufacturers provide different types of figures of merit when advertising the quality of their detector. It is hard for most laboratories to verify whether all of the anticipated specifications are met. In this report, a set of algorithms is presented to characterize on-axis slow-scan large-area CCD-based TEM detectors. These tools have been added to a publicly available image-processing toolbox for MATLAB. Three in-house CCD cameras were carefully characterized, yielding, among others, statistics for hot and bad pixels, the modulation transfer function, the conversion factor, the effective gain and the detective quantum efficiency. These statistics will aid data-collection strategy programs and provide prior information for quantitative imaging. The relative performance of the characterized detectors is discussed and a comparison is made with similar detectors that are used in the field of X-ray crystallography.
Asunto(s)
Cámaras gamma/estadística & datos numéricos , Procesamiento de Imagen Asistido por Computador/instrumentación , Microscopía Electrónica de Transmisión/instrumentación , Programas Informáticos , Algoritmos , Automatización , Cristalografía por Rayos X , Recolección de Datos , Humanos , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador/métodosRESUMEN
Microtubules (MTs) are dynamic structures of the eukaryotic cytoskeleton that, during cell division, form the mitotic spindle. Perturbing them leads to mitotic arrest and ultimately to cell death. Consistently, MTs and their building block, αß tubulin, are one of the best characterized targets in anti-cancer chemotherapy. Drugs that interfere with MTs either stabilize or destabilize them. The latter class is the subject of this review. These ligands bind to the colchicine site or to the vinca domain, two distinct sites located at a distance from each other on tubulin. Nevertheless the effects of both classes of ligands share a common theme, they prevent the formation of MT specific contacts, therefore triggering their disassembly.
RESUMEN
The study of temperature-dependent physical changes in flash-cooled macromolecular crystals is pertinent to cryocrystallography and related issues such as crystal annealing, X-ray radiation damage and kinetic crystallography. In this context, the unit-cell volume of flash-cooled trigonal and orthorhombic trypsin crystals has been monitored upon warming from 100 to 200 K and subsequent re-cooling to 100 K. Crystals of both forms were obtained under the same crystallization conditions, yet they differ in solvent content and channel size. An abrupt non-reversible unit-cell volume decrease is observed at 185 K in orthorhombic and at 195 K in trigonal crystals as the temperature is increased; this result is consistent with ultra-viscous solvent leaving the crystals. Concomitant appearance of ice rings in the diffraction patterns suggests that the transported solvent forms crystalline ice. These results demonstrate that solvent in flash-cooled protein crystals is liquid-like near its crystallization temperature, as has been proposed, yet controversially discussed, for the case of pure water. The use of mineral oil prevents the unit-cell volume decrease in trigonal but not in orthorhombic crystals. The observation of liquid-like solvent has implications in the development of annealing protocols and points a way to the rational design of temperature-controlled crystallographic studies that aim either at studying specific radiation damage or at trapping enzymatic intermediate states.