1.
Inorg Chem ; 62(2): 715-729, 2023 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-36595489

RESUMEN

Protonolysis reactions between dimethylamido titanium(IV) catecholate [Ti(CAT)(NMe2)2]2 and neopentanol or tris(tert-butoxy)silanol gave catecholato-bridged dimers [(Ti(CAT)(OCH2tBu)2)(HNMe2)]2 and [Ti(CAT){OSi(OtBu)3}2(HNMe2)2]2, respectively. Analogous reactions using the dimeric dimethylamido titanium(IV) (3,6-di-tert-butyl)catecholate [Ti(CATtBu2-3,6)(NMe2)2]2 yielded the monomeric Ti(CATtBu2-3,6)(OCH2tBu)2(HNMe2)2 and Ti(CATtBu2-3,6)[OSi(OtBu)3]2(HNMe2)2. The neopentoxide complex Ti(CATtBu2-3,6)(OCH2tBu)2(HNMe2)2 engaged in further protonolysis reactions with Si-OH groups and was consequentially used for grafting onto mesoporous silica KIT-6. Upon immobilization, the surface complex [Ti(CATtBu2-3,6)(OCH2tBu)2(HNMe2)2]@[KIT-6] retained the bidentate chelating geometry of the catecholato ligand. This convergent grafting strategy was compared with a sequential and an aqueous approach, which gave either a mixture of bidentate chelating species with a bipodally anchored Ti(IV) center along with other physisorbed surface species or not clearly identifiable surface species. Extension of the convergent and aqueous approaches to anatase mesoporous titania (m-TiO2) enabled optical and electronic investigations of the corresponding surface species, revealing that the band-gap reduction is more pronounced for the bidentate chelating species (convergent approach) than for that obtained via the aqueous approach. The applied methods include X-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, and solid-state UV/vis spectroscopy. The energy-level alignment for the surface species from the aqueous approach, calculated from experimental data, accounts for the well-known type II excitation mechanism, whereas the findings indicate a distinct excitation mechanism for the bidentate chelating surface species of the material [Ti(CATtBu2-3,6)(OCH2tBu)2(HNMe2)2]@[m-TiO2].

2.
Sensors (Basel) ; 23(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36616917

RESUMEN

UV hyperspectral imaging (225 nm-410 nm) was used to identify and quantify the honeydew content of real cotton samples. Honeydew contamination causes losses of millions of dollars annually. This study presents the implementation and application of UV hyperspectral imaging as a non-destructive, high-resolution, and fast imaging modality. For this novel approach, a reference sample set, which consists of sugar and protein solutions that were adapted to honeydew, was set-up. In total, 21 samples with different amounts of added sugars/proteins were measured to calculate multivariate models at each pixel of a hyperspectral image to predict and classify the amount of sugar and honeydew. The principal component analysis models (PCA) enabled a general differentiation between different concentrations of sugar and honeydew. A partial least squares regression (PLS-R) model was built based on the cotton samples soaked in different sugar and protein concentrations. The result showed a reliable performance with R2cv = 0.80 and low RMSECV = 0.01 g for the validation. The PLS-R reference model was able to predict the honeydew content laterally resolved in grams on real cotton samples for each pixel with light, strong, and very strong honeydew contaminations. Therefore, inline UV hyperspectral imaging combined with chemometric models can be an effective tool in the future for the quality control of industrial processing of cotton fibers.


Asunto(s)
Imágenes Hiperespectrales , Espectroscopía Infrarroja Corta , Carbohidratos , Análisis de los Mínimos Cuadrados , Azúcares
3.
Sensors (Basel) ; 21(24)2021 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-34960393

RESUMEN

Metalworking fluids (MWFs) are widely used to cool and lubricate metal workpieces during processing to reduce heat and friction. Extending a MWF's service life is of importance from both economical and ecological points of view. Knowledge about the effects of processing conditions on the aging behavior and reliable analytical procedures are required to properly characterize the aging phenomena. While so far no quantitative estimations of ageing effects on MWFs have been described in the literature other than univariate ones based on single parameter measurements, in the present study we present a simple spectroscopy-based set-up for the simultaneous monitoring of three quality parameters of MWF and a mathematical model relating them to the most influential process factors relevant during use. For this purpose, the effects of MWF concentration, pH and nitrite concentration on the droplet size during aging were investigated by means of a response surface modelling approach. Systematically varied model MWF fluids were characterized using simultaneous measurements of absorption coefficients µa and effective scattering coefficients µ's. Droplet size was determined via dynamic light scattering (DLS) measurements. Droplet size showed non-linear dependence on MWF concentration and pH, but the nitrite concentration had no significant effect. pH and MWF concentration showed a strong synergistic effect, which indicates that MWF aging is a rather complex process. The observed effects were similar for the DLS and the µ's values, which shows the comparability of the methodologies. The correlations of the methods were R2c = 0.928 and R2P = 0.927, as calculated by a partial least squares regression (PLS-R) model. Furthermore, using µa, it was possible to generate a predictive PLS-R model for MWF concentration (R2c = 0.890, R2P = 0.924). Simultaneous determination of the pH based on the µ's is possible with good accuracy (R²c = 0.803, R²P = 0.732). With prior knowledge of the MWF concentration using the µa-PLS-R model, the predictive capability of the µ's-PLS-R model for pH was refined (10 wt%: R²c = 0.998, R²p = 0.997). This highlights the relevance of the combined measurement of µa and µ's. Recognizing the synergistic nature of the effects of MWF concentration and pH on the droplet size is an important prerequisite for extending the service life of an MWF in the metalworking industry. The presented method can be applied as an in-process analytical tool that allows one to compensate for ageing effects during use of the MWF by taking appropriate corrective measures, such as pH correction or adjustment of concentration.


Asunto(s)
Metalurgia , Modelos Teóricos , Concentración de Iones de Hidrógeno
4.
Sensors (Basel) ; 21(21)2021 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-34770640

RESUMEN

Hyperspectral imaging and reflectance spectroscopy in the range from 200-380 nm were used to rapidly detect and characterize copper oxidation states and their layer thicknesses on direct bonded copper in a non-destructive way. Single-point UV reflectance spectroscopy, as a well-established method, was utilized to compare the quality of the hyperspectral imaging results. For the laterally resolved measurements of the copper surfaces an UV hyperspectral imaging setup based on a pushbroom imager was used. Six different types of direct bonded copper were studied. Each type had a different oxide layer thickness and was analyzed by depth profiling using X-ray photoelectron spectroscopy. In total, 28 samples were measured to develop multivariate models to characterize and predict the oxide layer thicknesses. The principal component analysis models (PCA) enabled a general differentiation between the sample types on the first two PCs with 100.0% and 96% explained variance for UV spectroscopy and hyperspectral imaging, respectively. Partial least squares regression (PLS-R) models showed reliable performance with R2c = 0.94 and 0.94 and RMSEC = 1.64 nm and 1.76 nm, respectively. The developed in-line prototype system combined with multivariate data modeling shows high potential for further development of this technique towards real large-scale processes.


Asunto(s)
Cobre , Imágenes Hiperespectrales , Análisis de los Mínimos Cuadrados , Óxidos , Análisis de Componente Principal
5.
Anal Bioanal Chem ; 413(30): 7363-7383, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34799750

RESUMEN

The early detection of head and neck cancer is a prolonged challenging task. It requires a precise and accurate identification of tissue alterations as well as a distinct discrimination of cancerous from healthy tissue areas. A novel approach for this purpose uses microspectroscopic techniques with special focus on hyperspectral imaging (HSI) methods. Our proof-of-principle study presents the implementation and application of darkfield elastic light scattering spectroscopy (DF ELSS) as a non-destructive, high-resolution, and fast imaging modality to distinguish lingual healthy from altered tissue regions in a mouse model. The main aspect of our study deals with the comparison of two varying HSI detection principles, which are a point-by-point and line scanning imaging, and whether one might be more appropriate in differentiating several tissue types. Statistical models are formed by deploying a principal component analysis (PCA) with the Bayesian discriminant analysis (DA) on the elastic light scattering (ELS) spectra. Overall accuracy, sensitivity, and precision values of 98% are achieved for both models whereas the overall specificity results in 99%. An additional classification of model-unknown ELS spectra is performed. The predictions are verified with histopathological evaluations of identical HE-stained tissue areas to prove the model's capability of tissue distinction. In the context of our proof-of-principle study, we assess the Pushbroom PCA-DA model to be more suitable for tissue type differentiations and thus tissue classification. In addition to the HE-examination in head and neck cancer diagnosis, the usage of HSI-based statistical models might be conceivable in a daily clinical routine.


Asunto(s)
Luz , Dispersión de Radiación , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de la Lengua/diagnóstico por imagen , Animales , Modelos Animales de Enfermedad , Femenino , Masculino , Ratones , Ratones Endogámicos C57BL , Análisis de Componente Principal , Reproducibilidad de los Resultados
6.
Anal Bioanal Chem ; 413(28): 7093-7106, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34599394

RESUMEN

The article analyzes experimentally and theoretically the influence of microscope parameters on the pinhole-assisted Raman depth profiles in uniform and composite refractive media. The main objective is the reliable mapping of deep sample regions. The easiest to interpret results are found with low magnification, low aperture, and small pinholes. Here, the intensities and shapes of the Raman signals are independent of the location of the emitter relative to the sample surface. Theoretically, the results can be well described with a simple analytical equation containing the axial depth resolution of the microscope and the position of the emitter. The lower determinable object size is limited to 2-4 µm. If sub-micrometer resolution is desired, high magnification, mostly combined with high aperture, becomes necessary. The signal intensities and shapes depend now in refractive media on the position relative to the sample surface. This aspect is investigated on a number of uniform and stacked polymer layers, 2-160 µm thick, with the best available transparency. The experimental depth profiles are numerically fitted with excellent accuracy by inserting a Gaussian excitation beam of variable waist and fill fraction through the focusing lens area, and by treating the Raman emission with geometric optics as spontaneous isotropic process through the lens and the variable pinhole, respectively. The intersectional area of these two solid angles yields the leading factor in understanding confocal (pinhole-assisted) Raman depth profiles. Spearfishing is a well-known example of the effects of refraction at the boundary between two index-mismatched media. The object Greal is seen, due to refraction, as Gvir from the angle ß (without knowing the depth position). The real position is obtained under the angle α. In a microscope (see inset), index mismatch deforms the image point of Greal into an image line. The pinhole substantially reduces deformations and allows the determination of the position of the point emitter G. (Cartoon designed by Sofia Anker).

7.
Sensors (Basel) ; 21(16)2021 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-34451034

RESUMEN

To correctly assess the cleanliness of technical surfaces in a production process, corresponding online monitoring systems must provide sufficient data. A promising method for fast, large-area, and non-contact monitoring is hyperspectral imaging (HSI), which was used in this paper for the detection and quantification of organic surface contaminations. Depending on the cleaning parameter constellation, different levels of organic residues remained on the surface. Afterwards, the cleanliness was determined by the carbon content in the atom percent on the sample surfaces, characterized by XPS and AES. The HSI data and the XPS measurements were correlated, using machine learning methods, to generate a predictive model for the carbon content of the surface. The regression algorithms elastic net, random forest regression, and support vector machine regression were used. Overall, the developed method was able to quantify organic contaminations on technical surfaces. The best regression model found was a random forest model, which achieved an R2 of 0.7 and an RMSE of 7.65 At.-% C. Due to the easy-to-use measurement and the fast evaluation by machine learning, the method seems suitable for an online monitoring system. However, the results also show that further experiments are necessary to improve the quality of the prediction models.


Asunto(s)
Cobre , Imágenes Hiperespectrales , Electrónica , Aprendizaje Automático , Máquina de Vectores de Soporte
8.
Polymers (Basel) ; 12(11)2020 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-33113786

RESUMEN

The chemical synthesis of polysiloxanes from monomeric starting materials involves a series of hydrolysis, condensation and modification reactions with complex monomeric and oligomeric reaction mixtures. Real-time monitoring and precise process control of the synthesis process is of great importance to ensure reproducible intermediates and products and can readily be performed by optical spectroscopy. In chemical reactions involving rapid and simultaneous functional group transformations and complex reaction mixtures, however, the spectroscopic signals are often ambiguous due to overlapping bands, shifting peaks and changing baselines. The univariate analysis of individual absorbance signals is hence often only of limited use. In contrast, batch modelling based on the multivariate analysis of the time course of principal components (PCs) derived from the reaction spectra provides a more efficient tool for real-time monitoring. In batch modelling, not only single absorbance bands are used but information over a broad range of wavelengths is extracted from the evolving spectral fingerprints and used for analysis. Thereby, process control can be based on numerous chemical and morphological changes taking place during synthesis. "Bad" (or abnormal) batches can quickly be distinguished from "normal" ones by comparing the respective reaction trajectories in real time. In this work, FTIR spectroscopy was combined with multivariate data analysis for the in-line process characterization and batch modelling of polysiloxane formation. The synthesis was conducted under different starting conditions using various reactant concentrations. The complex spectral information was evaluated using chemometrics (principal component analysis, PCA). Specific spectral features at different stages of the reaction were assigned to the corresponding reaction steps. Reaction trajectories were derived based on batch modelling using a wide range of wavelengths. Subsequently, complexity was reduced again to the most relevant absorbance signals in order to derive a concept for a low-cost process spectroscopic set-up which could be used for real-time process monitoring and reaction control.

9.
Anal Bioanal Chem ; 412(14): 3359-3371, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31897554

RESUMEN

The critical process parameters cell density and viability during mammalian cell cultivation are assessed by UV/VIS spectroscopy in combination with multivariate data analytical methods. This direct optical detection technique uses a commercial optical probe to acquire spectra in a label-free way without signal enhancement. For the cultivation, an inverse cultivation protocol is applied, which simulates the exponential growth phase by exponentially replacing cells and metabolites of a growing Chinese hamster ovary cell batch with fresh medium. For the simulation of the death phase, a batch of growing cells is progressively replaced by a batch with completely starved cells. Thus, the most important parts of an industrial batch cultivation are easily imitated. The cell viability was determined by the well-established method partial least squares regression (PLS). To further improve process knowledge, the viability has been determined from the spectra based on a multivariate curve resolution (MCR) model. With this approach, the progress of the cultivations can be continuously monitored solely based on an UV/VIS sensor. Thus, the monitoring of critical process parameters is possible inline within a mammalian cell cultivation process, especially the viable cell density. In addition, the beginning of cell death can be detected by this method which allows us to determine the cell viability with acceptable error. The combination of inline UV/VIS spectroscopy with multivariate curve resolution generates additional process knowledge complementary to PLS and is considered a suitable process analytical tool for monitoring industrial cultivation processes.


Asunto(s)
Recuento de Células , Supervivencia Celular , Espectrofotometría Ultravioleta/instrumentación , Animales , Técnicas de Cultivo Celular por Lotes/instrumentación , Células CHO , Cricetulus , Diseño de Equipo , Análisis de los Mínimos Cuadrados
10.
ChemistryOpen ; 8(8): 1084-1093, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31406655

RESUMEN

We report on the reflectance, transmittance and fluorescence spectra (λ=200-1200 nm) of four types of chicken eggshells (white, brown, light green, dark green) measured in situ without pretreatment and after ablation of 20-100 µm of the outer shell regions. The color pigment protoporphyrin IX (PPIX) is embedded in the protein phase of all four shell types as highly fluorescent monomers, in the white and light green shells additionally as non-fluorescent dimers, and in the brown and dark green shells mainly as non-fluorescent poly-aggregates. The green shell colors are formed from an approximately equimolar mixture of PPIX and biliverdin. The axial distribution of protein and colorpigments were evaluated from the combined reflectances of both the outer and inner shell surfaces, as well as from the transmittances. For the data generation we used the radiative transfer model in the random walk and Kubelka-Munk approaches.

11.
Eng Life Sci ; 19(5): 352-362, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-32625014

RESUMEN

A new two-dimensional fluorescence sensor system was developed for in-line monitoring of mammalian cell cultures. Fluorescence spectroscopy allows for the detection and quantification of naturally occurring intra- and extracellular fluorophores in the cell broth. The fluorescence signals correlate to the cells' current redox state and other relevant process parameters. Cell culture pretests with twelve different excitation wavelengths showed that only three wavelengths account for a vast majority of spectral variation. Accordingly, the newly developed device utilizes three high-power LEDs as excitation sources in combination with a back-thinned CCD-spectrometer for fluorescence detection. This setup was first tested in a lab design of experiments study with process relevant fluorophores proving its suitability for cell culture monitoring with LOD in the µg/L range. The sensor was then integrated into a CHO-K1 cell culture process. The acquired fluorescence spectra of several batches were evaluated using multivariate methods. The resulting batch evolution models were challenged in deviating and "golden batch" validation runs. These first tests showed that the new sensor can trace the cells' metabolic state in a fast and reliable manner. Cellular distress is quickly detected as a deviation from the "golden batch".

12.
Appl Spectrosc ; 73(1): 59-66, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30307327

RESUMEN

An ultraviolet visible (UV-Vis) spectroscopy method was developed that can quantitatively characterize a technical copper surface to determine oxide layers and organic impurities. The oxide layers were produced by a heating step at 175 ℃ for four different times (range = 1-10 min). Partial least squares (PLS) regression was used to establish a relation between the UV-Vis spectra and film thickness measurements using Auger electron spectroscopy depth profiles. The validation accuracy of the regression is in the range of approximately 2.3 nm. The prediction model allowed obtaining an estimation of the oxide layer thickness with an absolute error of 2.9 nm. Alternatively, already known methods cannot be used because of the high roughness of the technical copper surfaces. An integrating sphere is used to measure the diffuse reflectance of these surfaces, providing an average over all angles of illumination and observation.

13.
Anal Bioanal Chem ; 409(28): 6613-6623, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28918486

RESUMEN

This paper presents an approach for label-free brain tumor tissue typing. For this application, our dual modality microspectroscopy system combines inelastic Raman scattering spectroscopy and Mie elastic light scattering spectroscopy. The system enables marker-free biomedical diagnostics and records both the chemical and morphologic changes of tissues on a cellular and subcellular level. The system setup is described and the suitability for measuring morphologic features is investigated. Graphical Abstract Bimodal approach for label-free brain tumor typing. Elastic and inelastic light scattering spectra are collected laterally resolved in one measurement setup. The spectra are investigated by multivariate data analysis for assigning the tissues to specific WHO grades according to their malignancy.


Asunto(s)
Neoplasias Encefálicas/patología , Encéfalo/patología , Dispersión Dinámica de Luz/métodos , Espectrometría Raman/métodos , Química Encefálica , Neoplasias Encefálicas/química , Dispersión Dinámica de Luz/instrumentación , Diseño de Equipo , Humanos , Microscopía/métodos , Análisis Multivariante , Espectrometría Raman/instrumentación
14.
Anal Bioanal Chem ; 409(18): 4321-4333, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28343348

RESUMEN

Newly developed active pharmaceutical ingredients (APIs) are often poorly soluble in water. As a result the bioavailability of the API in the human body is reduced. One approach to overcome this restriction is the formulation of amorphous solid dispersions (ASDs), e.g., by hot-melt extrusion (HME). Thus, the poorly soluble crystalline form of the API is transferred into a more soluble amorphous form. To reach this aim in HME, the APIs are embedded in a polymer matrix. The resulting amorphous solid dispersions may contain small amounts of residual crystallinity and have the tendency to recrystallize. For the controlled release of the API in the final drug product the amount of crystallinity has to be known. This review assesses the available analytical methods that have been recently used for the characterization of ASDs and the quantification of crystalline API content. Well-established techniques like near- and mid-infrared spectroscopy (NIR and MIR, respectively), Raman spectroscopy, and emerging ones like UV/VIS, terahertz, and ultrasonic spectroscopy are considered in detail. Furthermore, their advantages and limitations are discussed with regard to general practical applicability as process analytical technology (PAT) tools in industrial manufacturing. The review focuses on spectroscopic methods which have been proven as most suitable for in-line and on-line process analytics. Further aspects are spectroscopic techniques that have been or could be integrated into an extruder.


Asunto(s)
Formas de Dosificación , Composición de Medicamentos , Tecnología Farmacéutica/instrumentación , Tecnología Farmacéutica/métodos , Química Farmacéutica , Diseño de Equipo , Calor
15.
Anal Bioanal Chem ; 409(3): 673-681, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27137513

RESUMEN

The influence of turbidity on the Raman signal strengths of condensed matter is theoretically analyzed and measured with laboratory - scale equipment for remote sensing. The results show the quantitative dependence of back- and forward-scattered signals on the thickness and elastic-scattering properties of matter. In the extreme situation of thin, highly turbid layers, the measured Raman signal strengths exceed their transparent analogs by more than a factor of ten. The opposite behavior is found for thick layers of low turbidity, where the presence of a small amount of scatterers leads to a decrease of the measured signal. The wide range of turbidities appearing in nature is experimentally realized with stacked polymer layers and solid/liquid dispersions, and theoretically modeled by the equation of radiative transfer using the analytical diffusion approximation or random walk simulations. Graphical abstract Spatial Raman emission profiles in transparent and turbid materials.

16.
Anal Bioanal Chem ; 408(21): 5701-5709, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27277813

RESUMEN

Current techniques for chromosome analysis need to be improved for rapid, economical identification of complex chromosomal defects by sensitive and selective visualisation. In this paper, we present a straightforward method for characterising unstained human metaphase chromosomes. Backscatter imaging in a dark-field setup combined with visible and short near-infrared spectroscopy is used to monitor morphological differences in the distribution of the chromosomal fine structure in human metaphase chromosomes. The reasons for the scattering centres in the fine structure are explained. Changes in the scattering centres during preparation of the metaphases are discussed. FDTD simulations are presented to substantiate the experimental findings. We show that local scattering features consisting of underlying spectral modulations of higher frequencies associated with a high variety of densely packed chromatin can be represented by their scatter profiles even on a sub-microscopic level. The result is independent of the chromosome preparation and structure size. This analytical method constitutes a rapid, cost-effective and label-free cytogenetic technique which can be used in a standard light microscope. Graphical abstract Hyperspectral backscatter imaging for label-free characterization.


Asunto(s)
Cromosomas/ultraestructura , Análisis Citogenético/métodos , Espectroscopía Infrarroja Corta/métodos , Cromosomas/química , Humanos , Metafase , Microscopía/métodos , Imagen Óptica/métodos , Cariotipificación Espectral/métodos
17.
Appl Spectrosc ; 67(4): 385-95, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23601538

RESUMEN

In continuation of our contribution to "The Axial Transfer" (Appl. Spectr. 2012. 66(8): 934-943), this paper describes the distribution of localized incident radiation in multiple scattering layers of arbitrary thickness and analyzes the lateral intensity profiles of radiation leaving the sample from its illuminated and non-illuminated surfaces. The theoretical profiles are calculated with different approximations of the equation of transfer. We derive for both non-absorbing and absorbing layers simple analytical expressions and verify their accuracy and range of applicability by comparison with Monte Carlo simulations. Particular emphasis is given to the analysis of the radial absorption, an under-theorized and under-investigated feature that can help to identify weak or hidden absorbers. In addition, we contribute to the description of how the radial reflectance is affected by anisotropy or by error sources like multiple surface reflection for samples in glass cells or deflectance (sideway loss) of radiation in small samples. Finally, the theoretical results are compared with experimental data of radial reflectance for quasi non-absorbing and absorbing powder layers.

18.
Appl Spectrosc ; 66(8): 934-43, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22800964

RESUMEN

The article presents two general equations of radiation penetration into layers of diffuse reflectors. One of the equations describes the depth origins of reflection, the other the depth profiles of absorption. The equations are evaluated within the theory of radiative transfer applying various degrees of analytical approximations and Monte Carlo simulations. The data are presented for different scattering and absorption coefficients, arbitrary layer thicknesses, collimated and diffused irradiation, and anisotropic forward scattering. The calculated mean depths of reflection are always lower than the mean depths of absorption. For nearly non-absorbing layers, the mean depths of absorption are about one third of the physical layer thickness. In contrast, penetration saturates for strong absorbers at very low depth levels. From the simulated data, methods are derived for the determination of the penetration depth from reflectance and transmittance data of thin layers or from radially diffused reflectance profiles upon spot irradiation. The methods are experimentally verified for a series of metal oxide powders with particle sizes ranging from much smaller to much larger than the wavelength of irradiation and for microcrystalline cellulose stained with different concentrations of an organic dye.

19.
Opt Express ; 18(3): 3116-27, 2010 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-20174146

RESUMEN

Light scattering measurements of particle aggregates contain complex information which is difficult to decrypt. Dark-field scattering microscopy in the visible range is used to characterize multi-arranged polystyrene beads. First, measured light scattering spectra of single spheres are compared with the Mie theory. Then, additional spectral measurements of three different sample sets of sphere aggregates are carried out. The aggregates consist of homogeneous spheres and differ in number of spheres, arrangement and contact area. Principal component analysis is used to reduce the number of variables and achieve an accurate classification regarding the aggregate characteristics.