1.
Cureus ; 11(10): e6014, 2019 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-31815078

RESUMEN

Introduction Image-guided robotic radiosurgery is an emerging minimally-invasive treatment option for trigeminal neuralgia (TN). Our group has treated 560 cases up to date, and report here the clinical outcomes of 387 treatments with three years follow-up. This study represents the largest single-center experience on CyberKnife radiosurgery for the treatment of TN so far reported. Methods CyberKnife radiosurgery treatment was offered to patients with drug-resistant TN, after the failure of other treatments or refusal of invasive procedures. A second treatment was offered to patients with a poor response after the first treatment or with recurrent pain. Treatment protocol required the non-isocentric delivery of 60 Gy prescribed to the 80% isodose to a 6 mm retrogasserian segment of the affected trigeminal nerve. Retreatments typically received 45 Gy, again prescribed to the 80% isodose. The final plan was developed accordingly to individual anatomy and dose distribution over the trigeminal nerve, gasserian ganglion, and brainstem. Clinical outcomes such as pain control and hypoesthesia/numbness have been evaluated after 6, 12, 24, and 36 months.  Results Our group has treated 527 patients with Cyberknife radiosurgery at Centro Diagnostico Italiano (CDI), Milan, Italy, during the last decade. A minimum follow-up of six months was available on 496 patients. These patients received 560 treatments: 435 patients (87.7%) had a single treatment, 60 patients (12.1%) had two treatments, and one patient (0.2%) had five treatments (two on the right side, three on the left side). Twenty four patients had multiple sclerosis (4.8%). Four hundred and forty-three patients (84%) received the treatment without previous procedures, while 84 patients (16%) underwent radiosurgery after the failure of other treatments. A neurovascular conflict was identified in 59% of the patients. Three hundred and forty-three patients (receiving a total of 387 treatments) had a minimum of 36 months follow up. Pain relief rate at 6, 12, 18, 24, 30 and 36 months was respectively 92, 87, 87, 82, 78 and 76%. Forty-four patients out of 343 (12.8%) required a second treatment during the observed period. At 36 months post-treatment, 21 patients (6,1%) reported the presence of bothering facial hypoesthesia. Eighteen patients out of 21 (85.7%) developed this complication after a repeated treatment.  Conclusions Frameless image-guided robotic radiosurgery in experienced hands is a safe and effective procedure for the treatment of TN, providing excellent pain control rates in the absence of major neurological complications. Repeated treatments due to recurrent pain are associated with restored pain control but at the price of a higher rate of sensory complications.

2.
Phys Med ; 65: 40-45, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31430585

RESUMEN

PURPOSE: The aims of this study were: (i) to validate in a multi-site context the suitability of the IBA Razor silicon diode detector for CyberKnife relative dosimetry. (ii) to fit the multi-center experimental data into a function relating the field output factors to the effective field size (EFS). METHODS AND MATERIALS: Ratio of detector readings in clinical and reference field (OFdet) and beam profiles were acquired on five CyberKnife units for fixed collimator diameters (range 5-60 mm), using both Razor and PTW 60017 diodes. Measured OFdet were corrected using published MonteCarlo correction factors to get field output factors ΩQclin,Qmsrfclin,fmsr. Profiles were analyzed in terms of penumbra and EFS. ΩQclin,Qmsrfclin,fmsr obtained in four centers were fitted as a function of EFS, while the data of the 5th center were used to validate the fitting curve. RESULTS: Differences between Razor and PTW60017 ΩQclin,Qmsrfclin,fmsr were within 1.5% over all centers down to 7.5 mm aperture and within 3.5% for the 5 mm diameter. The fit showed a coefficient of determination R2 = 0.997. The mean deviation of measured points from the predictive curve was within 0.5%. Data of the 5th center showed a mean deviation of 0.4% from the curve, with maximum differences within 2.5% for the 7.5 mm aperture. CONCLUSIONS: The results confirmed the suitability of Razor detector for CyberKnife dosimetry by comparison to the PTW 60017 diode which has been well characterized and is in widespread use. The proposed mathematical relation between ΩQclin,Qmsrfclin,fmsr and EFS is a robust predictive model applicable to different CyberKnife systems and detectors.


Asunto(s)
Equipos y Suministros Eléctricos , Radiometría/instrumentación , Radiocirugia/instrumentación , Animales , Aceleradores de Partículas , Silicio
3.
Phys Med ; 59: 47-54, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30928065

RESUMEN

PURPOSE: When a lung lesion is detected by only one couple of X-ray tube and image detector integrated with CyberKnife®, the fiducial-less tracking is limited to 1-view (34% of lung treatments at Centro Diagnostico Italiano). The aim of the study was mainly to determine the margin needed to take into account the localization uncertainty along the blind view (out-of-plane direction). METHODS: 36 patients treated in 2-view tracking modality (127 fractions in total) were included in the study. The actual tumor positions were determined retrospectively through logfile analysis and were projected onto 2D image planes. In the same plots the planned target positions based on biphasic breath-hold CT scans were represented preserving the metric with respect to the imaging center. The internal margin necessary to cover in out-of-plane direction the 95% of the target position distribution in the 95% of cases was calculated by home-made software in Matlab®. A validation test was preliminarily performed using XLT Phantom (CIRS) both in 2-view and 1-view scenarios. RESULTS: The validation test proved the reliability of the method, in spite of some intrinsic limitations. Margins were estimated equal to 5 and 6 mm for targets in upper and lower lobe respectively. Biphasic breath-hold CT led to underestimate the target movement in the hypothetical out-of-plane direction. The inter-fractional variability of spine-target distance was an important source of uncertainty for 1-view treatments. CONCLUSION: This graphic comparison method preserving metric could be employed in the clinical workflow of 1-view treatments to get patient-related information for customized margin definition.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Radiocirugia , Procedimientos Quirúrgicos Robotizados , Contencion de la Respiración , Fraccionamiento de la Dosis de Radiación , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/fisiopatología , Fantasmas de Imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Incertidumbre
4.
Phys Med ; 32(12): 1637-1643, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27499371

RESUMEN

PURPOSE: New promising detectors are available for measuring small field size output factors (OFs). This study focused on a multicenter evaluation of two new generation detectors for OF measurements on CyberKnife systems. METHODS: PTW-60019 microDiamond and W1 plastic scintillation detector (PSD) were used to measure OFs on eight CyberKnife units of various generations for 5-60mm fixed cones. MicroDiamond and PSD OF were compared to routinely used silicon diodes data corrected applying published Monte Carlo (MC) factors. PSD data were corrected for Cerenkov Light Ratio (CLR). The uncertainties related to CLR determination were estimated. RESULTS: Considering OF values averaged over all centers, the differences between MC corrected diode and the other two detectors were within 1.5%. MicroDiamond exhibited an over-response of 1.3% at 7.5mm and a trend inversion at 5mm with a difference of 0.2%. This behavior was consistent among the different units. OFs measured by PSD slightly under-responded compared to MC corrected diode for the smaller cones and the differences were within 1%. The observed CLR variability was 2.5% and the related variation in OF values was 1.9%. CONCLUSION: This study indicates that CyberKnife microDiamond OF require corrections below 2%. The results are enhanced by the consistency observed among different units. Scintillator shows a good agreement to MC corrected diode but CLR determination remains critical requiring further investigations. The results emphasized the value of a multi-center validation over a single center approach.


Asunto(s)
Radiocirugia/métodos , Diamante , Método de Montecarlo , Radiocirugia/instrumentación
5.
Phys Med ; 32(4): 600-6, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27061871

RESUMEN

PURPOSE: A large-scale multi-institutional planning comparison on lung cancer SABR is presented with the aim of investigating possible criticism in carrying out retrospective multicentre data analysis from a dosimetric perspective. METHODS: Five CT series were sent to the participants. The dose prescription to PTV was 54Gy in 3 fractions of 18Gy. The plans were compared in terms of PTV-gEUD2 (generalized Equivalent Uniform Dose equivalent to 2Gy), mean dose to PTV, Homogeneity Index (PTV-HI), Conformity Index (PTV-CI) and Gradient Index (PTV-GI). We calculated the maximum dose for each OAR (organ at risk) considered as well as the MLD2 (mean lung dose equivalent to 2Gy). The data were stratified according to expertise and technology. RESULTS: Twenty-six centers equipped with Linacs, 3DCRT (4% - 1 center), static IMRT (8% - 2 centers), VMAT (76% - 20 centers), CyberKnife (4% - 1 center), and Tomotherapy (8% - 2 centers) collaborated. Significant PTV-gEUD2 differences were observed (range: 105-161Gy); mean-PTV dose, PTV-HI, PTV-CI, and PTV-GI were, respectively, 56.8±3.4Gy, 14.2±10.1%, 0.70±0.15, and 4.9±1.9. Significant correlations for PTV-gEUD2 versus PTV-HI, and MLD2 versus PTV-GI, were observed. CONCLUSIONS: The differences in terms of PTV-gEUD2 may suggest the inclusion of PTV-gEUD2 calculation for retrospective data inter-comparison.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Radiocirugia/instrumentación , Tomografía Computarizada por Rayos X/métodos
6.
Radiat Oncol ; 10: 132, 2015 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-26071401

RESUMEN

BACKGROUND: A multidisciplinary and multi-institutional working group applied the Failure Mode and Effects Analysis (FMEA) approach to assess the risks for patients undergoing Stereotactic Body Radiation Therapy (SBRT) treatments for lesions located in spine and liver in two CyberKnife® Centres. METHODS: The various sub-processes characterizing the SBRT treatment were identified to generate the process trees of both the treatment planning and delivery phases. This analysis drove to the identification and subsequent scoring of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system. Novel solutions aimed to increase patient safety were accordingly considered. RESULTS: The process-tree characterising the SBRT treatment planning stage was composed with a total of 48 sub-processes. Similarly, 42 sub-processes were identified in the stage of delivery to liver tumours and 30 in the stage of delivery to spine lesions. All the sub-processes were judged to be potentially prone to one or more failure modes. Nineteen failures (i.e. 5 in treatment planning stage, 5 in the delivery to liver lesions and 9 in the delivery to spine lesions) were considered of high concern in view of the high RPN and/or severity index value. CONCLUSIONS: The analysis of the potential failures, their causes and effects allowed to improve the safety strategies already adopted in the clinical practice with additional measures for optimizing quality management workflow and increasing patient safety.


Asunto(s)
Análisis de Modo y Efecto de Fallas en la Atención de la Salud , Neoplasias Hepáticas/cirugía , Radiocirugia , Neoplasias de la Columna Vertebral/cirugía , Humanos , Italia , Errores Médicos , Seguridad del Paciente , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Radiocirugia/efectos adversos , Radiocirugia/instrumentación , Riesgo , Insuficiencia del Tratamiento
7.
Scand J Gastroenterol ; 50(4): 429-38, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25633726

RESUMEN

OBJECTIVE: Hyperferritinemia is frequent in chronic liver diseases of any cause, but the extent to which ferritin truly reflects iron stores is variable. In these patients, both liver iron and fat are found in variable amount and association. Liver biopsy is often required to quantify liver fat and iron, but sampling variability and invasiveness limit its use. We aimed to assess single breath-hold multiecho magnetic resonance imaging (MRI) for the simultaneous lipid and iron quantification in patients with hyperferritinemia. MATERIAL AND METHODS: We compared MRI results for both iron and fat with their respective gold standards - liver iron concentration and computer-assisted image analysis for steatosis on biopsy. We prospectively studied 67 patients with hyperferritinemia and other 10 consecutive patients were used for validation. We estimated two linear calibration equations for the prediction of iron and fat based on MRI. The agreement between MRI and biopsy was evaluated. RESULTS: MRI showed good performances in both the training and validation samples. MRI information was almost completely in line with that obtained from liver biopsy. CONCLUSION: Single breath-hold multiecho MRI is an accurate method to obtain a valuable measure of both liver iron and steatosis in patients with hyperferritinemia.


Asunto(s)
Tejido Adiposo , Hígado Graso/patología , Hierro/análisis , Hígado/química , Hígado/patología , Imagen por Resonancia Magnética , Biopsia , Femenino , Humanos , Hierro/sangre , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos