Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Med Dosim ; 46(1): 80-85, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32988718

RESUMEN

The purpose of this study was to compare 3D treatment plans implemented using 6 MV Linac with a retrofitted multileaf collimator (MLC) based cobalt-60 plans. In this retrospective study, DVH analysis was used to compare homogeneity of dose within the target and the dose received by critical organs. A prototype MLC designed and developed as a retrofit to current cobalt-60 teletherapy machines with a dedicated 3D treatment planning system was used. Cases representing 5 tumor sites like head & neck, glottis, lung, gall bladder, stomach were taken for the study, which were planned using Eclipse treatment planning system and treated with 6 MV photon beams. The plans were re-planned using the retrofit cobalt-60 MLC with same beam arrangement and dose prescription in Radiation Oncology planning system (ROPS). For each case, DVH data was evaluated for both types of beam energies. Conformity index (CI) and homogeneity index (HI) for target were calculated and compared. The conformal plans created using cobalt MLC for five sites were found to be similar to those planned using 6 MV photon beams. CI values close to unity reflected dose uniformity in the target volume while HI evaluated the hotspots in the target volume. It was concluded that plans created using retrofit prototype MLC developed for cobalt-60 teletherapy machines can provide dose distributions comparable to 6 MV photon beams. The prototype MLC developed can provide a promising treatment option for existing telecobalt machines in implementing conformal therapy in developing countries.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia Conformacional , Radioisótopos de Cobalto/uso terapéutico , Humanos , Estudios Retrospectivos
2.
J Med Phys ; 45(4): 215-220, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33953496

RESUMEN

AIM: The objective of this study was to evaluate skin dose based on retrofit prototype multileaf collimators (MLCs), designed for cobalt-60 teletherapy machine. Since patient's skin is sensitive to radiation, evaluation of skin dose is of utmost importance for investigating the risk of late effects. MATERIALS AND METHODS: Measurements were performed with a Phoenix cobalt-60 teletherapy machine and the detector used was EBT3 radiochromic film. The experiments were performed in a solid water phantom with two prototype MLCs mounted to the machine. Dose readings were taken by placing the films at source-to-surface distance (SSD) of 60 cm, 65 cm, 70 cm, 75 cm, 80 cm, 85 cm, and 90 cm for various MLC-generated field sizes starting from 2 cm × 2 cm to 14 cm × 14 cm. The films were analyzed using custom made programs. The measured doses were normalized to the dose at dmax for that particular measurement of SSD. RESULTS: The skin dose is expressed as a percentage of dose at dose maximum. In general, the skin dose increases with field size and decreases with SSD. The measurements indicate surface doses within 20%-60% for the investigated SSD range. Furthermore, there is no significant difference between the surface doses of two prototype MLCs studied. CONCLUSIONS: From the measurements, it can be concluded that there is good skin sparing even at close distance to the MLCs. The skin dose is <50% for SSDs >65 cm. A minimum gap of 5 cm is required to produce acceptable skin dose.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...