1.
Resuscitation ; 200: 110259, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38823474

RESUMEN

BACKGROUND: Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends. METHODS: Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation. RESULTS: Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (-0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (-0.7 vs. -2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg). CONCLUSION: Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.


Asunto(s)
Dióxido de Carbono , Reanimación Cardiopulmonar , Paro Cardíaco Extrahospitalario , Humanos , Reanimación Cardiopulmonar/métodos , Reanimación Cardiopulmonar/normas , Masculino , Femenino , Estudios Retrospectivos , Paro Cardíaco Extrahospitalario/terapia , Persona de Mediana Edad , Dióxido de Carbono/análisis , Anciano , Capnografía/métodos , Volumen de Ventilación Pulmonar/fisiología
2.
Heliyon ; 10(7): e28739, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38601572

RESUMEN

Aim: Propose new metrics of impulsiveness of manual chest compressions (CCs) that account for shape and duration, separate the characteristics of the compressive part of the CC cycle from those of the recoil part, and are uncorrelated to CC depth and rate. Methods: We conducted a retrospective analysis of adult out-of-hospital cardiac arrest monitor-defibrillator recordings having CPR data. Specifically, episodes of adult patients with ≥ 1000 compressions free of leaning were examined. CCs were obtained from the depth signal of the valid episodes, and we calculated the novel metrics: compression area index (CAI), recoil area index (RAI), compression impulsiveness index (CII) and recoil impulsiveness index (RII). Generalized linear mixed-effects models and Jonckheere-Terpstra trend analyses were employed to measure differences between populations and trends, and the absolute value of Pearson's correlation coefficient |r| was used to report dependence between variables. Statistics are reported as median and interquartile range. Results: We analyzed 982,340 CCs corresponding to 453 episodes, for which we calculated their CAI, RAI and duty cycle (DC). We analyzed the metrics for various populations: age, sex, any ROSC achieved and disposition, and found that CAI was significantly different according to patient disposition and RAI relative to age and sex (p<0.05). None of the metrics was correlated strongly to depth or rate (|r| values of 0.22 or smaller), and all of them varied for CC series corresponding to the same rescuer over the course of resuscitation (ptrend<0.05). However, we observed that the metrics are not balanced, in that for any value of DC, CAI and RAI span almost their entire ranges. Conclusion: The proposed metrics correctly and completely describe manual CC waveforms, improve upon the DC, since they depend on the signal waveform, and provide additional information to current indicators of quality CPR, depth and rate. Furthermore, they allow to differentiate the compressive and recoil parts of the CC cycle, reflecting influence of the rescuer (via CAI or CII) and of the biomechanics of the patient's chest (via RAI or RII). Thus, they have the potential to contribute to better understanding CPR dynamics and, eventually, to enhanced quality of CPR practice as additional indicators of proper manual CC technique.

3.
J Clin Med ; 12(21)2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37959385

RESUMEN

Background: There is growing interest in the quality of manual ventilation during cardiopulmonary resuscitation (CPR), but accurate assessment of ventilation parameters remains a challenge. Waveform capnography is currently the reference for monitoring ventilation rate in intubated patients, but fails to provide information on tidal volumes and inspiration-expiration timing. Moreover, the capnogram is often distorted when chest compressions (CCs) are performed during ventilation compromising its reliability during CPR. Our main purpose was to characterize manual ventilation during CPR and to assess how CCs may impact on ventilation quality. Methods: Retrospective analysis were performed of CPR recordings fromtwo databases of adult patients in cardiac arrest including capnogram, compression depth, and airway flow, pressure and volume signals. Using automated signal processing techniques followed by manual revision, individual ventilations were identified and ventilation parameters were measured. Oscillations on the capnogram plateau during CCs were characterized, and its correlation with compression depth and airway volume was assessed. Finally, we identified events of reversed airflow caused by CCs and their effect on volume and capnogram waveform. Results: Ventilation rates were higher than the recommended 10 breaths/min in 66.7% of the cases. Variability in ventilation rates correlated with the variability in tidal volumes and other ventilatory parameters. Oscillations caused by CCs on capnograms were of high amplitude (median above 74%) and were associated with low pseudo-volumes (median 26 mL). Correlation between the amplitude of those oscillations with either the CCs depth or the generated passive volumes was low, with correlation coefficients of -0.24 and 0.40, respectively. During inspiration and expiration, reversed airflow events caused opposed movement of gases in 80% of ventilations. Conclusions: Our study confirmed lack of adherence between measured ventilation rates and the guideline recommendations, and a substantial dispersion in manual ventilation parameters during CPR. Oscillations on the capnogram plateau caused by CCs did not correlate with compression depth or associated small tidal volumes. CCs caused reversed flow during inspiration, expiration and in the interval between ventilations, sufficient to generate volume changes and causing oscillations on capnogram. Further research is warranted to assess the impact of these findings on ventilation quality during CPR.

4.
Resuscitation ; 179: 225-232, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35835250

RESUMEN

AIM: Characterise how changes in chest compression depth and rate affect variations in end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) in out-of-hospital cardiac arrest (OHCA). METHODS: Retrospective analysis of adult OHCA monitor-defibrillator recordings having concurrent capnogram, compression depth, transthoracic impedance and ECG, and with atleast 1,000 compressions. Within each patient, during no spontaneous circulation, nearby segments with changes in chest compression depth and rate were identified. Average ETCO2 within each segment was standardised to compensate for ventilation rate variability. Contributions of relative variations in depth and rate to relative variations in standardised ETCO2 were characterised using linear and non-linear models. Normalisation between paired segments removed intra and inter-patient variation and made coefficients of the model independent of the scale of measurement and therefore directly comparable. RESULTS: A total of 394 pairs of segments from 221 patients were analysed (33% female, median (IQR) age 66 (55-74) years). Chest compression depth and rate were 50.4 (43.2-57.0)mm and 111.1 (106.5-116.1)compressions per minute. ETCO2 before and after standardization was 32.1 (23.0-41.4)mmHg and 28.5 (19.4-38.7)mmHg. Linear model coefficient of determination was 0.89. Variation in compression depth mainly explained ETCO2 variation (coefficient 0.95, 95% confidence interval (CI): 0.93-0.98) while changes in compression rate did not (coefficient 0.04, 95% CI: 0.01-0.07). Non-linear trend analysis confirmed the results. CONCLUSION: This study quantified the relative importance of chest compression characteristics in terms of their impact on CO2 production during CPR. With ventilation rate standardised, variation in chest compression depth explained variations in ETCO2 better than variation in chest compression rate.


Asunto(s)
Reanimación Cardiopulmonar , Paro Cardíaco Extrahospitalario , Adulto , Anciano , Dióxido de Carbono/análisis , Reanimación Cardiopulmonar/métodos , Femenino , Hospitales , Humanos , Masculino , Paro Cardíaco Extrahospitalario/terapia , Estudios Retrospectivos