Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Bioengineering (Basel) ; 10(10)2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37892904

RESUMEN

Graft fixation during cruciate ligament reconstruction using interference screws is a common and frequently used surgical technique. These interference screws are usually made of metal or bioabsorbable materials. This paper describes the development of an allograft interference screw from cortical human bone. During the design of the screw, particular attention was paid to the choice of the screw drive and the screw shape, as well as the thread shape. Based on these parameters, a prototype was designed and manufactured. Subsequently, the first biomechanical tests using a bovine model were performed. The test procedure comprised a torsion test to determine the ultimate failure torque of the screw and the insertion torque during graft fixation, as well as a pull-out test to asses the ultimate failure load of the graft fixation. The results of the biomechanical analysis showed that the mean value of the ultimate failure torque was 2633 Nmm, whereas the mean occurring insertion torque during graft fixation was only 1125 Nmm. The mean ultimate failure load of the graft fixation was approximately 235 N. The results of this work show a good overall performance of the allograft screw compared to conventional screws, and should serve as a starting point for further detailed investigations and studies.

2.
J Bone Joint Surg Am ; 101(10): 868-878, 2019 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-31094978

RESUMEN

BACKGROUND: The risk of femoral stem fracture after total hip replacement is low and can often be associated with a specific implant system or other factors that may reduce the fatigue strength. Additionally, damage to a metal component during revision surgery by an electrocautery device may further affect the fatigue behavior. METHODS: Two clinical cases of stem failure after revision of fractured ceramic components are presented; the retrieved components were analyzed for the cause of failure. In vitro cyclic load-to-failure testing of titanium alloy femoral stems after electrocautery application at 2 different locations (at the base and about midway on the femoral neck) was performed using a stepwise increase in load until implant fracture occurred. In addition, a detailed characterization of the local material structure around the electrocautery marks was performed. RESULTS: Superficial discoloration and melting marks were found on the retrieved components, including at the location of crack initiation in the anterolateral region, which may have reduced the fatigue strength of the material. In addition, elemental analysis indicated material transfer from the electrocautery tip. Damage to the surface by the electrocautery device significantly reduced the in vitro load to failure by up to 47% compared with that of undamaged femoral neck specimens. Material analysis revealed a relevant modification in microstructure, with an extension of approximately 2.7 mm and a depth of 550 µm, which could be divided in 3 structural zones. CONCLUSIONS: Intraoperative electrocautery device contact with the implant during surgical revision of a total hip replacement cannot always be avoided. However, on the basis of our findings, the risk of implant failure is increased due to a change in microstructure and a potential reduction of the implant's fatigue strength. Surgeons and manufacturers of electrocautery devices should be aware of this concern. CLINICAL RELEVANCE: During revision surgery, contact between an electrocautery device and the femoral component should be avoided to reduce the chance of subsequent femoral neck fracture.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Electrocoagulación/efectos adversos , Prótesis de Cadera , Falla de Prótesis , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Electrocoagulación/instrumentación , Análisis de Falla de Equipo , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación
3.
Eur J Radiol ; 85(2): 489-97, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26781156

RESUMEN

OBJECTIVES: To retrospectively assess the diagnostic performance of hip MR arthrography with and without traction in detecting ligamentum teres (LT) lesions with arthroscopic correlation and to evaluate the effect of traction on the imaging appearance of the LT. METHODS: 73 MR arthrograms (73 consecutive patients, mean age, 34.5 years; range, 14-55 years) obtained without and with leg traction (application of 15-23 kg, use of a supporting plate for the contralateral leg) were included. Two blinded readers independently evaluated LT lesions on MR arthrograms on separate occasions: coronal images without traction; coronal images with traction; a multiplanar traction protocol. MR findings were correlated with arthroscopic records. Sensitivity/specificity of traction and non-traction imaging was compared on coronal images with the exact McNemar test. Imaging appearance of the LT with and without traction was assessed in consensus and compared on coronal images using McNemar and McNemar-Bowker tests. (p<0.05, * corrected for type I error). RESULTS: With arthroscopy 29 (40%) LT lesions were identified in 73 patients. Sensitivity was 72%/90% (without traction/with traction; p=0.25*), specificity was 89%/77% (p=0.25*) for reader 1 in assessing coronal images and for reader 2 sensitivity was 59%/86% (p=0.044*) and specificity was 93%/82% (p=0.25*). Alterations in fiber orientation, signal intensity, surface, dimension, fiber continuity after application of traction were observed in 33/73 (45%, p=0.002*), 6/73 (8%, p=0.223), 9/73 (12%, p=0.36*), 6/73 (8%, p=0.031) respectively 9/73 (12%, p=0.003) cases. Traction-related alterations in at least one criterion were observed in 41/73 (56%) cases. CONCLUSION: Application of traction can considerably alter the imaging appearance of the LT and resulted in higher rates of true-positive and false-positive findings compared to conventional MR arthrography.


Asunto(s)
Artrografía/métodos , Artroscopía/métodos , Lesiones de la Cadera/patología , Imagen por Resonancia Magnética/métodos , Ligamentos Redondos/lesiones , Ligamentos Redondos/patología , Tracción , Adolescente , Adulto , Medios de Contraste , Femenino , Gadolinio DTPA , Articulación de la Cadera/patología , Humanos , Aumento de la Imagen , Yopamidol , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
5.
Eur Radiol ; 25(6): 1721-30, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25465714

RESUMEN

OBJECTIVES: To assess diagnostic performance of traction MR arthrography of the hip in detection and grading of chondral and labral lesions with arthroscopic comparison. METHODS: Seventy-five MR arthrograms obtained ± traction of 73 consecutive patients (mean age, 34.5 years; range, 14-54 years) who underwent arthroscopy were included. Traction technique included weight-adapted traction (15-23 kg), a supporting plate for the contralateral leg, and intra-articular injection of 18-27 ml (local anaesthetic and contrast agent). Patients reported on neuropraxia and on pain. Two blinded readers independently assessed femoroacetabular cartilage and labrum lesions which were correlated with arthroscopy. Interobserver agreement was calculated using κ values. Joint distraction ± traction was evaluated in consensus. RESULTS: No procedure had to be stopped. There were no cases of neuropraxia. Accuracy for detection of labral lesions was 92 %/93 %, 91 %/83 % for acetabular lesions, and 92 %/88 % for femoral cartilage lesions for reader 1/reader 2, respectively. Interobserver agreement was moderate (κ = 0.58) for grading of labrum lesions and substantial (κ = 0.7, κ = 0.68) for grading of acetabular and femoral cartilage lesions. Joint distraction was achieved in 72/75 and 14/75 hips with/without traction, respectively. CONCLUSION: Traction MR arthrography safely enabled accurate detection and grading of labral and chondral lesions. KEY POINTS: • The used traction technique was well tolerated by most patients. • The used traction technique almost consistently achieved separation of cartilage layers. • Traction MR arthrography enabled accurate detection of chondral and labral lesions.


Asunto(s)
Enfermedades de los Cartílagos/patología , Articulación de la Cadera/patología , Artropatías/patología , Adolescente , Adulto , Artrografía/métodos , Artroscopía/métodos , Cartílago Articular/patología , Medios de Contraste , Femenino , Humanos , Inyecciones Intraarticulares , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Tracción/métodos , Adulto Joven
6.
Acad Radiol ; 21(10): 1240-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24981959

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate the feasibility of a modified approach for direct magnetic resonance (MR) arthrography of the hip under leg traction in achieving a sufficient femoroacetabular interface and improving the visualization of the ligamentum teres. MATERIALS AND METHODS: Forty-six MR arthrograms of 44 patients who underwent MR arthrography with and without leg traction were included into the study. Traction approach included injection of 18-27 mL of fluid (local anesthetic, contrast agent), application of weight-adapted traction load (15-23 kg), and the use of a supporting plate. Patients were instructed to report on pain and complications with an integer pain scale. Joint distraction was measured on coronal images obtained with and without traction, and two radiologists independently evaluated whether femoroacetabular cartilage layers and the ligamentum teres could be seen as distinct entities. McNemar test was used and interobserver agreement was assessed. RESULTS: No patient asked for termination of the examination. There were no cases of neuropraxia. Mean difference in distraction was 3.7 mm/3.6 mm (reader 1/reader 2). Cartilage layers could be seen as distinct entities in 43/43 (93.5%/93.5%) and 6/8 (13%/17.4%) of the joints with/without traction (P < .001/P < .001), respectively. The ligamentum teres could be differentiated in 33/30 (71.7%/65.2%) cases with traction, in 33/30 (71.7%/65.2%) cases without traction (P < .999/P < .999), and in 40/37 (87%/80.4%) cases with both the techniques combined. CONCLUSIONS: Traction MR arthrography is safe and technically feasible. It enabled the differentiation between femoroacetabular cartilage layers in most cases. Visualization of the ligamentum teres was optimal by combining imaging with both modalities.


Asunto(s)
Cartílago Articular/patología , Articulación de la Cadera/patología , Aumento de la Imagen/métodos , Ligamentos Articulares/patología , Imagen por Resonancia Magnética/métodos , Posicionamiento del Paciente/métodos , Tracción/métodos , Algoritmos , Artralgia/diagnóstico , Artralgia/etiología , Artrografía/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Humanos , Variaciones Dependientes del Observador , Posicionamiento del Paciente/efectos adversos , Posicionamiento del Paciente/instrumentación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Tracción/efectos adversos , Tracción/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...