Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Arch Gynecol Obstet ; 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38796557

RESUMEN

BACKGROUND: We used two 3D ultrasound volumes of fetal heads at 13 weeks to create live-size 3D-printed phantoms with a view to training or assessment of diagnostic abilities for normal and abnormal nuchal translucency measurements. The phantoms are suitable for use in a water bath, imitating a real-life exam. They were then used to study measurement accuracy and reproducibility in examiners of different skill levels. METHODS: Ultrasound scans of a 13 + 0-week fetus were processed using 3D Slicer software, producing a stereolithography file for 3D printing. The model, crafted in Autodesk Fusion360™, adhered to FMF guidelines for NT dimensions (NT 2.3 mm). Additionally, a model with pathologic NT was designed (NT 4.2 mm). Printing was performed via Formlabs Form 3® printer using High Temp Resin V2. The externally identical looking 3D models were embedded in water-filled condoms for ultrasound examination. Eight specialists of varying expertise levels conducted five NT measurements for each model, classifying them in physiological and abnormal models. RESULTS: Classification of the models in physiological or abnormal NT resulted in a detection rate of 100%. Average measurements for the normal NT model and the increased NT model were 2.27 mm (SD ± 0.38) and 4.165 mm (SD ± 0.51), respectively. The interrater reliability was calculated via the intraclass correlation coefficient (ICC) which yielded a result of 0.883, indicating robust agreement between the raters. Cost-effectiveness analysis demonstrated the economical nature of the 3D printing process. DISCUSSION: This study underscores the potential of 3D printed fetal models for enhancing ultrasound training through high inter-rater reliability, consistency across different expert levels, and cost-effectiveness. Limitations, including population variability and direct translation to clinical outcomes, warrant further exploration. The study contributes to ongoing discussions on integrating innovative technologies into medical education, offering a practical and economical method to acquire, refine and revise diagnostic skills in prenatal ultrasound. Future research should explore broader applications and long-term economic implications, paving the way for transformative advancements in medical training and practice.

2.
JACC Case Rep ; 29(11): 102344, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38666000

RESUMEN

Infective endocarditis requiring mitral valve replacement during pregnancy is a rare event. We present a case of infective endocarditis of the mitral valve during second trimester and report maternal and perinatal outcomes. Prompt identification and interdisciplinary treatment is crucial; maternal and fetal follow-up including serial fetal neurosonography is recommended.

3.
Proc Natl Acad Sci U S A ; 117(21): 11781-11787, 2020 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-32385158

RESUMEN

Benzodiazepines (BZDs) represent the gold standard of anxiolytic pharmacotherapy; however, their clinical benefit is limited by side effects and addictive potential. Consequently, there is an urgent need to develop novel and safe anxiolytics. The peptide hormone oxytocin (OXT) exhibits anxiolytic-like properties in animals and humans, but whether OXT and BZDs share similar effects on the neural circuitry of fear is unclear. Therefore, the rationale of this ultra-high-field functional MRI (fMRI) study was to test OXT against the clinical comparator lorazepam (LZP) with regard to their neuromodulatory effects on local and network responses to fear-related stimuli. One hundred twenty-eight healthy male participants volunteered in this randomized double-blind, placebo-controlled, between-group study. Before scanning using an emotional face-matching paradigm, participants were randomly administered a single dose of OXT (24 IU), LZP (1 mg), or placebo. On the behavioral level, LZP, but not OXT, caused mild sedation, as evidenced by a 19% increase in reaction times. On the neural level, both OXT and LZP inhibited responses to fearful faces vs. neutral faces within the centromedial amygdala (cmA). In contrast, they had different effects on intra-amygdalar connectivity; OXT strengthened the coupling between the cmA and basolateral amygdala, whereas LZP increased the interplay between the cmA and superficial amygdala. Furthermore, OXT, but not LZP, enhanced the coupling between the cmA and the precuneus and dorsomedial prefrontal cortex. These data implicate inhibition of the cmA as a common denominator of anxiolytic action, with only OXT inducing large-scale connectivity changes of potential therapeutic relevance.


Asunto(s)
Amígdala del Cerebelo , Miedo/efectos de los fármacos , Lorazepam/farmacología , Oxitocina/farmacología , Adulto , Amígdala del Cerebelo/diagnóstico por imagen , Amígdala del Cerebelo/efectos de los fármacos , Amígdala del Cerebelo/fisiología , Miedo/fisiología , Humanos , Imagen por Resonancia Magnética , Masculino , Neurotransmisores/farmacología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...