Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
EJNMMI Radiopharm Chem ; 4(1): 24, 2019 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-31659546

RESUMEN

BACKGROUND: PET radiopharmaceutical development and the implementation of a production method on a synthesis module is a complex and time-intensive task since new synthesis methods must be adapted to the confines of the synthesis platform in use. Commonly utilized single fluid bus architectures put multiple constraints on synthesis planning and execution, while conventional microfluidic solutions are limited by compatibility at the macro-to-micro interface. In this work we introduce the ISAR synthesis platform and custom-tailored fluid paths leveraging up to 70 individually addressable valves on a chip-based consumable. The ISAR synthesis platform replaces traditional stopcock valve manifolds with a fluidic chip that integrates all fluid paths (tubing) and valves into one consumable and enables channel routing without the single fluid bus constraint. ISAR can scale between the macro- (10 mL), meso- (0.5 mL) and micro- (≤0.05 mL) domain seamlessly, addressing the macro-to-micro interface challenge and enabling custom tailored fluid circuits for a given application. In this paper we demonstrate proof-of-concept by validating a single chip design to address the challenge of synthesizing multiple batches of [13N]NH3 for clinical use throughout the workday. RESULTS: ISAR was installed at an academic PET Center and used to manufacture [13N]NH3 in > 96% radiochemical yield. Up to 9 batches were manufactured with a single consumable chip having parallel paths without the need to open the hot-cell. Quality control testing confirmed the ISAR-based [13N]NH3 met existing clinical release specifications, and utility was demonstrated by imaging a rodent with [13N]NH3 produced on ISAR. CONCLUSIONS: ISAR represents a new paradigm in radiopharmaceutical production. Through a new system architecture, ISAR integrates the principles of microfluidics with the standard volumes and consumables established in PET Centers all over the world. Proof-of-concept has been demonstrated through validation of a chip design for the synthesis of [13N]NH3 suitable for clinical use.

2.
Lab Chip ; 14(14): 2556-64, 2014 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-24879121

RESUMEN

The application of microfluidics to the synthesis of Positron Emission Tomography (PET) tracers has been explored for more than a decade. Microfluidic benefits such as superior temperature control have been successfully applied to PET tracer synthesis. However, the design of a compact microfluidic platform capable of executing a complete PET tracer synthesis workflow while maintaining prospects for commercialization remains a significant challenge. This study uses an integral system design approach to tackle commercialization challenges such as the material to process compatibility with a path towards cost effective lab-on-chip mass manufacturing from the start. It integrates all functional elements required for a simple PET tracer synthesis into one compact radiochemistry platform. For the lab-on-chip this includes the integration of on-chip valves, on-chip solid phase extraction (SPE), on-chip reactors and a reversible fluid interface while maintaining compatibility with all process chemicals, temperatures and chip mass manufacturing techniques. For the radiochemistry device it includes an automated chip-machine interface enabling one-move connection of all valve actuators and fluid connectors. A vial-based reagent supply as well as methods to transfer reagents efficiently from the vials to the chip has been integrated. After validation of all those functional elements, the microfluidic platform was exemplarily employed for the automated synthesis of a Gastrin-releasing peptide receptor (GRP-R) binding the PEGylated Bombesin BN(7-14)-derivative ([(18)F]PESIN) based PET tracer.


Asunto(s)
Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas , Radioquímica , Radiofármacos , Bombesina/química , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/métodos , Trazadores Radiactivos , Radioquímica/instrumentación , Radioquímica/métodos , Radiofármacos/síntesis química , Radiofármacos/química , Receptores de Bombesina/química
3.
Bioconjug Chem ; 25(4): 738-49, 2014 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-24666287

RESUMEN

Gastrin-releasing-peptide (GRP)-receptors and αvß3-integrins are widely discussed as potential target structures for oncological imaging with positron emission tomography (PET). Favored by the overexpression of receptors on the surface of tumor cells good imaging characteristics can be achieved with highly specific radiolabeled receptor ligands. PEGylated bombesin (PESIN) derivatives as specific GRP receptor ligands and RGD (one-letter codes for arginine-glycine-aspartic acid) peptides as specific αvß3 binders were synthesized and tagged with a silicon-fluorine-acceptor (SiFA) moiety. The SiFA synthon allows for a fast and highly efficient isotopic exchange reaction at room temperature giving the [(18)F]fluoride labeled peptides in up to 62% radiochemical yields (d.c.) and ≥99% radiochemical purity in a total synthesis time of less than 20 min. Using nanomolar quantities of precursor high specific activities of up to 60 GBq µmol(-1) were obtained. To compensate the high lipophilicity of the SiFA moiety various hydrophilic structure modifications were introduced leading to significantly reduced logD values. Competitive displacement experiments with the PESIN derivatives showed a 32 to 6 nM affinity to the GRP receptor on PC3 cells, and with the RGD peptides a 7 to 3 µM affinity to the αvß3 integrins on U87MG cells. All derivatives proved to be stable in human plasma over at least 120 min. Small animal PET measurements and biodistribution studies revealed an enhanced and specific accumulation of the RGD peptide (18)F-SiFA-LysMe3-γ-carboxy-d-Glu-RGD (17) in the tumor tissue of U87MG tumor-bearing mice of 5.3% ID/g whereas the PESIN derivatives showed a high liver uptake and only a low accumulation in the tumor tissue of PC3 xenografts. Stability studies with compound 17 provided further information on its metabolism in vivo. These results altogether demonstrate that the reduction of the overall lipophilicity of SiFA tagged RGD peptides is a promising approach for the generation of novel potent (18)F-labeled imaging agents.


Asunto(s)
Bombesina/metabolismo , Radioisótopos de Flúor/química , Imagen Molecular/métodos , Neoplasias Experimentales/metabolismo , Oligopéptidos/metabolismo , Tomografía de Emisión de Positrones/métodos , Silicio/química , Animales , Bombesina/química , Bombesina/farmacocinética , Femenino , Radioisótopos de Flúor/metabolismo , Radioisótopos de Flúor/farmacocinética , Humanos , Masculino , Ratones , Ratones Desnudos , Ratones SCID , Sondas Moleculares/síntesis química , Sondas Moleculares/química , Sondas Moleculares/metabolismo , Sondas Moleculares/farmacocinética , Estructura Molecular , Oligopéptidos/química , Oligopéptidos/farmacocinética , Silicio/metabolismo , Silicio/farmacocinética , Células Tumorales Cultivadas
4.
Molecules ; 18(7): 7930-56, 2013 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-23884128

RESUMEN

Application of microfluidics to Positron Emission Tomography (PET) tracer synthesis has attracted increasing interest within the last decade. The technical advantages of microfluidics, in particular the high surface to volume ratio and resulting fast thermal heating and cooling rates of reagents can lead to reduced reaction times, increased synthesis yields and reduced by-products. In addition automated reaction optimization, reduced consumption of expensive reagents and a path towards a reduced system footprint have been successfully demonstrated. The processing of radioactivity levels required for routine production, use of microfluidic-produced PET tracer doses in preclinical and clinical imaging as well as feasibility studies on autoradiolytic decomposition have all given promising results. However, the number of microfluidic synthesizers utilized for commercial routine production of PET tracers is very limited. This study reviews the state of the art in microfluidic PET tracer synthesis, highlighting critical design aspects, strengths, weaknesses and presenting several characteristics of the diverse PET market space which are thought to have a significant impact on research, development and engineering of microfluidic devices in this field. Furthermore, the topics of batch- and single-dose production, cyclotron to quality control integration as well as centralized versus de-centralized market distribution models are addressed.


Asunto(s)
Microfluídica/métodos , Tomografía de Emisión de Positrones , Trazadores Radiactivos , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentación , Control de Calidad , Radioisótopos , Radiofármacos/síntesis química
5.
Appl Radiat Isot ; 70(8): 1691-7, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22750198

RESUMEN

Autoradiolysis describes the degradation of radioactively labeled compounds due to the activity of the labeled compounds themselves. It scales with activity concentration and is of importance for high activity and microfluidic PET tracer synthesis. This study shows that microfluidic devices can be shaped to reduce autoradiolysis by geometric exclusion of positron interaction. A model is developed and confirmed by demonstrating in-capillary storage of non-stabilized [(18)F]FDG (2-[(18)F]Fluoro-2-deoxy-d-glucose) at max. 23 GBq/ml while maintaining >90% radiochemical purity over 14 h.


Asunto(s)
Microfluídica/instrumentación , Radiofármacos/química , Modelos Teóricos , Método de Montecarlo , Tomografía de Emisión de Positrones
6.
Molecules ; 16(9): 7458-79, 2011 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-21892125

RESUMEN

The synthesis, radiolabeling and in vitro evaluation of new silicon-fluoride acceptor (SiFA) derivatized D(2)-receptor ligands is reported. The SiFA-technology simplifies the introduction of fluorine-18 into target specific biomolecules for Positron-Emission-Tomography (PET). However, one of the remaining challenges, especially for small molecules such as receptor-ligands, is the bulkiness of the SiFA-moiety. We therefore synthesized four Fallypride SiFA-conjugates derivatized either directly at the benzoic acid ring system (SiFA-DMFP, SiFA-FP, SiFA-DDMFP) or at the butyl-side chain (SiFA-M-FP) and tested their receptor affinities. We found D(2)-receptor affinities for all compounds in the nanomolar range (K(i(SiFA-DMFP)) = 13.6 nM, K(i(SiFA-FP)) = 33.0 nM, K(i(SiFA-DDMFP)) = 62.7 nM and K(i(SiFA-M-FP)) = 4.21 nM). The radiofluorination showed highest yields when 10 nmol of the precursors were reacted with [(18)F]fluoride/TBAHCO(3) in acetonitrile. After a reversed phased cartridge purification the desired products could be isolated as an injectable solution after only 10 min synthesis time with radiochemical yields (RCY) of more than 40% in the case of SiFA-DMFP resulting in specific activities >41 GBq/µmol (>1,100 Ci/mmol). Furthermore, the radiolabeled products were shown to be stable in the injectable solutions, as well as in human plasma, for at least 90 min.


Asunto(s)
Benzamidas/síntesis química , Antagonistas de los Receptores de Dopamina D2 , Fluoruros/síntesis química , Radioisótopos de Flúor/química , Radiofármacos/síntesis química , Compuestos de Silicona/síntesis química , Benzamidas/química , Cristalografía por Rayos X , Fluoruros/química , Humanos , Modelos Moleculares , Conformación Molecular , Estructura Molecular , Tomografía de Emisión de Positrones , Unión Proteica , Radiofármacos/química , Receptores de Dopamina D2/química , Compuestos de Silicona/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...