RESUMEN
BACKGROUND: Re-irradiation is an increasingly utilized treatment for recurrent, metastatic or new malignancies after previous radiotherapy. It is unclear how re-irradiation is applied in clinical practice. We aimed to investigate the patterns of care of re-irradiation internationally. MATERIAL/METHODS: A cross-sectional survey conducted between March and September 2022. The survey was structured into six sections, each corresponding to a specific anatomical region. Participants were instructed to complete the sections of their clinical expertise. A total of 15 multiple-choice questions were included in each section, addressing various aspects of the re-irradiation process. The online survey targeted radiation and clinical oncologists and was endorsed by the European Society for Radiotherapy and Oncology (ESTRO) and the European Organisation for Research and Treatment of Cancer (EORTC). RESULTS: 371 physicians from 55 countries across six continents participated. Participants had a median professional experience of 16 years, and the majority (60%) were affiliated with an academic hospital. The brain region was the most common site for re-irradiation (77%), followed by the pelvis (65%) and head and neck (63%). Prolonging local control was the most common goal (90-96% across anatomical regions). The most common minimum interval between previous radiotherapy and re-irradiation was 6-12 months (45-55%). Persistent grade 3 or greater radiation-induced toxicity (77-80%) was the leading contraindication. Variability in organs at risk dose constraints for re-irradiation was observed. Advanced imaging modalities and conformal radiotherapy techniques were predominantly used. A scarcity of institutional guidelines for re-irradiation was reported (16-19%). Participants from European centers more frequently applied thoracic and abdominal re-irradiation. Indications did not differ between academic and non-academic hospitals. CONCLUSION: This study highlights the heterogeneity in re-irradiation practices across anatomical regions and emphasizes the need for high-quality evidence from prospective studies to guide treatment decisions and derive safe cumulative dose constraints.
Asunto(s)
Radioterapia Conformacional , Reirradiación , Humanos , Reirradiación/métodos , Estudios Transversales , Estudios Prospectivos , Recurrencia Local de Neoplasia/patologíaRESUMEN
BACKGROUND: Dosimetry after radiopharmaceutical therapy with 177Lu (177Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera using two different reconstruction algorithms: an ordered subset expectation maximization (OSEM) and a block sequential regularized expectation maximization (BSREM) combined with noise reduction regularization. This study lays the foundations for the definition of a reconstruction protocol enabling accurate dosimetry for patients treated with 177Lu-RPT. METHODS: A series of 177Lu-filled phantoms were acquired on a StarGuide™ (GE HealthCare), with energy and scatter windows centred at 208 (± 6%) keV and 185 (± 5%) keV, respectively. Images were reconstructed with the manufacturer implementations of OSEM (GE-OSEM) and BSREM (Q.Clear) algorithms, and various combinations of iterations and subsets. Additionally, the manufacturer-recommended Q.Clear-based reconstruction protocol was evaluated. Quantification accuracy, measured as the difference between the SPECT-based and the radionuclide calibrator-based activity, and noise were evaluated in a large cylinder. Recovery coefficients (RCs) and spatial resolution were assessed in a NEMA IEC phantom with sphere inserts. The reconstruction protocols considered suitable for clinical applications were tested on a cohort of patients treated with [177Lu]Lu-PSMA-I&T. RESULTS: The accuracy of the activity from the cylinder, although affected by septal penetration, was < 10% for all reconstructions. Both algorithms featured improved spatial resolution and higher RCs with increasing updates at the cost of noise build-up, but Q.Clear outperformed GE-OSEM in reducing noise accumulation. When the reconstruction parameters were carefully selected, similar values for noise (~0.15), spatial resolution (~1 cm) and RCs were found, irrespective of the reconstruction algorithm. Analogue results were found in patients. CONCLUSIONS: Accurate activity quantification is possible when imaging 177Lu with StarGuide™. However, the impact of septal penetration requires further investigations. GE-OSEM is a valid alternative to the recommended Q.Clear reconstruction algorithm, featuring comparable performances assessed on phantoms and patients.
RESUMEN
Background and purpose: 4D Computed Tomography (4DCT) technology captures the location and movement of tumors and nearby organs at risk over time. In this study, a multi-institutional multi-vendor 4DCT audit was initiated to assess the accuracy of current imaging protocols. Materials and methods: Twelve centers, including thirteen scanners performed a 4DCT acquisition of a dynamic thorax phantom using the institution's own protocol with the in-house breathing monitoring system. Five regular and three irregular breathing patterns were used. Image acquisition and reconstruction were followed by automated image analysis with our in-house developed 4DCT QA program (QAMotion). CT number accuracy, volume deviation, amplitude deviation, and spatial integrity were assessed per pattern using both the segmented volumes and line profiles. Results: Regular breathing curves showed relatively accurate results across all institutions, with mean volume and CT number deviations and median amplitude deviation below 2%, 5 HU and 2 mm, respectively. Results obtained for irregular patterns showed more variation across the institutions. Volume and CT number deviations co-occurred with a blurring of the sphere, interpolation, or double-structure artifacts that were confirmed through the line profiles. For some of the irregular patterns, amplitude deviations up to 6 mm were observed. Maximum Intensity Projection (MaxIP) correctly captured the applied motion amplitude with deviations across all institutions within 2 mm except for double amplitude pattern. Conclusions: All centers invited to participate in the audit responded positively, highlighting the need for a comprehensive yet easy-to-execute 4DCT quality assurance program. The largest variances between the results from one institution to another confirmed that a standardized 4DCT audit is warranted.
RESUMEN
This study aimed to develop and validate a comprehensive, reproducible and automatic 4DCT Quality Assurance (QA) workflow (QAMotion) that evaluates image accuracy across various regular and irregular breathing patterns. Volume and amplitude deviations, CT number accuracy, and spatial integrity were used as evaluation metrics. For repeatability tests, tolerances were respected with a mean CT number deviation < 10 HU, volume deviation < 2% and diameter and amplitude deviation < 2 mm except for irregular amplitude curves for which an amplitude deviation up to 6 mm was measured. QAMotion was able to flag image artefacts for our clinical 4DCT system.
RESUMEN
PURPOSE: The aim of this study was to perform a quantitative quality assurance of diffusion-weighted MRI to assess the variability of the mean apparent diffusion coefficient (ADC) and other radiomic features across the scanners involved in the REGINA trial. MATERIALS AND METHODS: The NIST/QIBA diffusion phantom was acquired on six 3 T scanners from five centres with a rectum-specific diffusion protocol. All sequences were repeated in each scan session without moving the phantom from the table. Linear interpolation to two isotropic voxel spacing (0.9 and 4 mm) was performed as well as the ComBat feature harmonisation method between scanners. The absolute accuracy error was evaluated for the mean ADC. Repeatability and reproducibility within-subject coefficients of variation (wCV) were computed for 142 radiomic features. RESULTS: For the mean ADC, accuracy error ranged between 0.1 % and 8.5 %, repeatability was <1 % and reproducibility was <3 % for diffusivity range between 0.4 and 1.1x10-3mm2/s. For the other radiomic features, wCV was below 10 % for 24 % and 15 % features for repeatability with resampling 0.9 mm and 4 mm, respectively, and 13 % and 11 % feature for reproducibility. ComBat method could improve significantly the wCV compared to reproducibility without ComBat (p-value < 0.001) but variation was still high for most of the features. CONCLUSION: Our study provided the first investigation of feature selection for development of robust predictive models in the REGINA trial, demonstrating the added value of such a quality assurance process to select conventional and radiomic features in prospective multicentre trials.
Asunto(s)
Imagen de Difusión por Resonancia Magnética , Reproducibilidad de los Resultados , Estudios Prospectivos , Fantasmas de Imagen , DifusiónRESUMEN
INTRODUCTION: Radiomics is a promising imaging-based tool which could enhance clinical observation and identify representative features. To avoid different interpretations, the Image Biomarker Standardisation Initiative (IBSI) imposed conditions for harmonisation. This study evaluates IBSI-compliant radiomics applications against a known benchmark and clinical datasets for agreements. MATERIALS AND METHODS: The three radiomics platforms compared were RadiomiX Research Toolbox, LIFEx v7.0.0, and syngo.via Frontier Radiomics v1.2.5 (based on PyRadiomics v2.1). Basic assessment included comparing feature names and their formulas. The IBSI digital phantom was used for evaluation against reference values. For agreement evaluation (including same software but different versions), two clinical datasets were used: 27 contrast-enhanced computed tomography (CECT) of colorectal liver metastases and 39 magnetic resonance imaging (MRI) of breast cancer, including intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) MRI. The intraclass correlation coefficient (ICC, lower 95% confidence interval) was used, with 0.9 as the threshold for excellent agreement. RESULTS: The three radiomics applications share 41 (3 shape, 8 intensity, 30 texture) out of 172, 84 and 110 features for RadiomiX, LIFEx and syngo.via, respectively, as well as wavelet filtering. The naming convention is, however, different between them. Syngo.via had excellent agreement with the IBSI benchmark, while LIFEx and RadiomiX showed slightly worse agreement. Excellent reproducibility was achieved for shape features only, while intensity and texture features varied considerably with the imaging type. For intensity, excellent agreement ranged from 46% for the DCE maps to 100% for CECT, while this lowered to 44% and 73% for texture features, respectively. Wavelet features produced the greatest variation between applications, with an excellent agreement for only 3% to 11% features. CONCLUSION: Even with IBSI-compliance, the reproducibility of features between radiomics applications is not guaranteed. To evaluate variation, quality assurance of radiomics applications should be performed and repeated when updating to a new version or adding a new modality.
Asunto(s)
Imagen por Resonancia Magnética , Programas Informáticos , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos XRESUMEN
Re-irradiation can be considered for local recurrence or new tumours adjacent to a previously irradiated site to achieve durable local control for patients with cancer who have otherwise few therapeutic options. With the use of new radiotherapy techniques, which allow for conformal treatment plans, image guidance, and short fractionation schemes, the use of re-irradiation for different sites is increasing in clinical settings. Yet, prospective evidence on re-irradiation is scarce and our understanding of the underlying radiobiology is poor. Our consensus on re-irradiation aims to assist in re-irradiation decision making, and to standardise the classification of different forms of re-irradiation and reporting. The consensus has been endorsed by the European Society for Radiotherapy and Oncology and the European Organisation for Research and Treatment of Cancer. The use of this classification in daily clinical practice and research will facilitate accurate understanding of the clinical implications of re-irradiation and allow for cross-study comparisons. Data gathered in a uniform manner could be used in the future to make recommendations for re-irradiation on the basis of clinical evidence. The consensus document is based on an adapted Delphi process and a systematic review of the literature was done according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA).
Asunto(s)
Neoplasias , Reirradiación , Toma de Decisiones Clínicas , Consenso , Humanos , Neoplasias/radioterapia , Estudios ProspectivosRESUMEN
PURPOSE: To update the 2011 ESTRO-EFOMP core curriculum (CC) for education and training of medical physics experts (MPE)s working in radiotherapy (RT), in line with recent EU guidelines, and to provide a framework for European countries to develop their own curriculum. MATERIAL AND METHODS: Since September 2019, 27 European MPEs representing ESTRO, EFOMP and National Societies, with expertise covering all subfields of RT physics, have revised the CC for recent advances in RT. The ESTRO and EFOMP Education Councils, all European National Societies and international stakeholders have been involved in the revision process. RESULTS: A 4-year training period has been proposed, with a total of 240 ECTS (European Credit Transfer and Accumulation System). Training entrance levels have been defined ensuring the necessary physics and mathematics background. The concept of competency-based education has been reinforced by introducing the CanMEDS role framework. The updated CC includes (ablative) stereotactic-, MR-guided- and adaptive RT, particle therapy, advanced automation, complex quantitative data analysis (big data/artificial intelligence), use of biological images, and personalized treatments. Due to the continuously increasing RT complexity, more emphasis has been given to quality management. Clear requirements for a research project ensure a proper preparation of MPE residents for their central role in science and innovation in RT. CONCLUSION: This updated, 3rd edition of the CC provides an MPE training framework for safe and effective practice of modern RT, while acknowledging the significant efforts needed in some countries to reach this level. The CC can contribute to further harmonization of MPE training in Europe.
Asunto(s)
Inteligencia Artificial , Oncología por Radiación , Curriculum , Europa (Continente) , Física Sanitaria/educación , Humanos , Oncología por Radiación/educaciónRESUMEN
BACKGROUND AND PURPOSE: To evaluate dosimetric differences in unintended dose to the lower axilla between 3D-standard (3DCRT), tangential beam forward intensity modulated radiotherapy (F-IMRT) and volumetric modulated arc therapy (VMAT). The objective is to evaluate whether results of clinical trials, such as the ACOSOG-Z011 trial, that evaluated omission of axillary clearance can be extrapolated towards more conformal techniques like VMAT. MATERIALS AND METHODS: Twenty-five consecutive patients treated with whole breast radiotherapy alone (WBRT) using a F-IMRT technique were identified. Three additional plans were created for every patient: one plan using a single 270° arc (VMAT 1x270°), another using two small ≤90° opposing arcs (VMAT 2x < 90°) and thirdly a 3DCRT plan without F-IMRT. Axillary levels I-II were contoured after the treatment plans were made. RESULTS: The volume of the axilla level I that was covered by the 50% isodose (V50%) was significantly higher for VMAT 2x < 90° (71.3 cm3, 84% of structure volume, p < 0.001) and VMAT 1x270° (68.8 cm3, 81%, p < 0.01) compared to 3DCRT (60.3 cm3, 71%) and F-IMRT (60.8 cm3, 72%). The V50% to the axilla level II, however, was low for all techniques: 12.3 cm3 (12%); 8.9 cm3 (9%); 4.3 cm3 (4%); 4.4 cm3 (4%) for VMAT 2x < 90°, VMAT 1x270°, 3DCRT, F-IMRT, respectively. For the higher doses (V90% and above), no clinically relevant differences were seen between the different modalities. CONCLUSION: WBRT treatments with VMAT do not lead to a significant reduction of the unintended axillary dose in comparison with a tangential beam setup. Hence, concerning tumor control, VMAT can be applied to clinical situations similar to the Z0011 trial. The intermediate axillary dose is higher with VMAT, but the clinical consequence of this difference on toxicity is unknown.
Asunto(s)
Neoplasias de la Mama , Radioterapia de Intensidad Modulada , Axila , Neoplasias de la Mama/radioterapia , Femenino , Humanos , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia AdyuvanteRESUMEN
PURPOSE: The dose calculated using a convolution algorithm should be validated in a simple homogeneous water-equivalent phantom before clinical use. The dose calculation accuracy within a solid water phantom was investigated. METHODS: The specific Gamma knife design requires a dose rate calibration within a spherical solid water phantom. The TMR10 algorithm, which approximates the phantom material as liquid water, correctly computes the absolute dose in water. The convolution algorithm, which considers electron density miscalculates the dose in water as the phantom Hounsfield units were converted into higher electron density when the original CT calibration curve was used. To address this issue, the electron density of liquid water was affected by modifying the CT calibration curve. The absolute dose calculated using the convolution algorithm was compared with that computed by the TMR10. The measured depth dose profiles were also compared to those computed by the convolution and TMR10 algorithms. A patient treatment was recalculated in the solid-water phantom and the delivery quality assurance was checked. RESULTS: The convolution algorithm and the TMR10 calculate an absolute dose within 1% when using the modified CT calibration curve. The dose depth profile calculated using the convolution algorithms was superimposed on the TMR10 and measured dose profiles when the modified CT calibration curve was applied. The Gamma index was better than 93%. CONCLUSIONS: Dose calculation algorithms, which consider electron density, require a CT calibration curve adapted to the phantom material to correctly compute the dose in water.
Asunto(s)
Radiocirugia , Agua , Algoritmos , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por ComputadorRESUMEN
Over the last years, technological innovation in Radiotherapy (RT) led to the introduction of Magnetic Resonance-guided RT (MRgRT) systems. Due to the higher soft tissue contrast compared to on-board CT-based systems, MRgRT is expected to significantly improve the treatment in many situations. MRgRT systems may extend the management of inter- and intra-fraction anatomical changes, offering the possibility of online adaptation of the dose distribution according to daily patient anatomy and to directly monitor tumor motion during treatment delivery by means of a continuous cine MR acquisition. Online adaptive treatments require a multidisciplinary and well-trained team, able to perform a series of operations in a safe, precise and fast manner while the patient is waiting on the treatment couch. Artificial Intelligence (AI) is expected to rapidly contribute to MRgRT, primarily by safely and efficiently automatising the various manual operations characterizing online adaptive treatments. Furthermore, AI is finding relevant applications in MRgRT in the fields of image segmentation, synthetic CT reconstruction, automatic (on-line) planning and the development of predictive models based on daily MRI. This review provides a comprehensive overview of the current AI integration in MRgRT from a medical physicist's perspective. Medical physicists are expected to be major actors in solving new tasks and in taking new responsibilities: their traditional role of guardians of the new technology implementation will change with increasing emphasis on the managing of AI tools, processes and advanced systems for imaging and data analysis, gradually replacing many repetitive manual tasks.
Asunto(s)
Inteligencia Artificial , Radioterapia Guiada por Imagen , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Planificación de la Radioterapia Asistida por ComputadorRESUMEN
BACKGROUND: To improve split-VMAT technique by optimizing treatment delivery time for deep-inspiration breath hold (DIBH) radiotherapy in left-sided breast cancer patients, when automatic beam-interruption devices are not available. METHODS: Ten consecutive patients were treated with an eight partial arcs (8paVMAT) plan, standard of care in our center. A four partial arcs (4paVMAT) plan was also created and actual LINAC outputs were measured, to evaluate whether there was a dosimetric difference between both techniques and potential impact on the delivered dose. Subsequently, ten other patients were consecutively treated with a 4paVMAT plan to compare the actual treatment delivery time between both techniques. The prescribed dose was 40.05 Gy/15 fractions on the PTV breast (breast or thoracic wall), lymph nodes (LN) and intramammary lymph node chain (IMN). Treatment delivery time, PTVs coverage, conformity index (CI), organs at risk (OAR) dose, monitor units (MU), and gamma index were compared. RESULTS: Both split-VMAT techniques resulted in similar dose coverage for the PTV Breast and LN, and similar CI. For PTV IMN we observed a 5% increased coverage for the volume receiving ≥ 36 Gy with 4paVMAT, with an identical volume receiving ≥ 32 Gy. There was no difference for the OAR sparing, with the exception of the contralateral organs: there was a 0.6 Gy decrease for contralateral breast mean (p ≤ 0.01) and 1% decrease for the volume of right lung receiving ≥ 5 Gy (p = 0.024). Overall, these results indicate a modest clinical benefit of using 4paVMAT in comparison to 8paVMAT. An increase in the number of MU per arc was observed for the 4paVMAT technique, as expected, while the total number of MU remained comparable for both techniques. All the plans were measured with the Delta4 phantom and passed the gamma index criteria with no significant differences. Finally, the main difference was seen for the treatment delivery time: there was a significant decrease from 8.9 to 5.4 min for the 4paVMAT plans (p < .05). CONCLUSIONS: This study is mainly of interest for centers who are implementing the DIBH technique without automatic beam-holding devices and who therefore may require to manually switch the beam on and off during breast DIBH treatment. Split-VMAT technique with 4 partial arcs significantly reduces the treatment delivery time compared to 8 partial arcs, without compromising the target coverage and the OAR sparing. The technique decreases the number of breath holds per fraction, resulting in a shorter treatment session.
Asunto(s)
Neoplasias de la Mama/radioterapia , Contencion de la Respiración , Radioterapia/métodos , Neoplasias de Mama Unilaterales/radioterapia , Anciano , Mama , Femenino , Humanos , Persona de Mediana Edad , Órganos en Riesgo , Fantasmas de Imagen , Dosis de Radiación , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , RespiraciónRESUMEN
PURPOSE: MR-to-CT synthesis is one of the first steps in the establishment of an MRI-only workflow in radiotherapy. Current MR-to-CT synthesis methods in deep learning use unpaired MR and CT training images with a cycle generative adversarial network (CycleGAN) to minimize the effect of misalignment between paired images. However, this approach critically assumes that the underlying interdomain mapping is approximately deterministic and one-to-one. In the current study, we use an Augmented CycleGAN (AugCGAN) model to create a robust model that can be applied to different scanners and sequences using unpaired data. MATERIALS AND METHODS: This study included T2-weighted MR and CT pelvic images of 38 patients in treatment position from five different centers. The AugCGAN was trained on 2D transverse slices of 19 patients from three different sites. The network was then used to generate synthetic CT (sCT) images of 19 patients from the two other sites. Mean absolute errors (MAEs) for each patient were evaluated between real and synthetic CT images. Original treatment plans of nine patients were recalculated using sCT images to assess the dose distribution in terms of voxel-wise dose difference, gamma, and dose-volume histogram analysis. RESULTS: The mean MAEs were 59.8 Hounsfield units ( HU ) and 65.8 HU for the first and second test sites, respectively. The maximum dose difference to the target was 1.2 % with a gamma pass rate using the 3%, 3 mm criteria above 99%. The average time required to generate a complete sCT image for a patient on our GPU was 8.5 s. CONCLUSION: This study suggests that our unpaired approach achieves good performance in generalization with respect to sCT image generation.
Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Imagen por Resonancia Magnética , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos XRESUMEN
PURPOSE/OBJECTIVE: The objective of this study was to verify the accuracy of treatment plans of stereotactic body radiation therapy (SBRT) and to verify the feasibility of the use of Monte Carlo (MC) as quality control (QC) on a daily basis. MATERIAL/METHODS: Using EGSnrc, a MC model of Agility™ linear accelerator was created. Various measurements (Percentage depth dose (PDD), Profiles and Output factors) were done for different fields sizes from 1x1 up to 40x40 (cm2). An iterative model optimization was performed to achieve adequate parameters of MC simulation. 40 SBRT patient's dosimetry plans were calculated by Monaco™ 3.1.1. CT images, RT-STRUCT and RT-PLAN files from Monaco™ being used as input for Moderato MC code. Finally, dose volume histogram (DVH) and paired t-tests for each contour were used for dosimetry comparison of the Monaco™ and MC. RESULTS: Validation of MC model was successful, as <2% difference comparing to measurements for all field's sizes. The main energy of electron source incident on the target was 5.8 MeV, and the full width at half maximum (FWHM) of Gaussian electron source were 0.09 and 0.2 (cm) in X and Y directions, respectively. For 40 treatment plan comparisons, the minimum absolute difference of mean dose of planning treatment planning (PTV) was 0.1% while the maximum was 6.3%. The minimum absolute difference of Max dose of PTV was 0.2% while the maximum was 8.1%. CONCLUSION: SBRT treatment plans of Monaco agreed with MC results. It possible to use MC for treatment plans verifications as independent QC tool.
Asunto(s)
Radiocirugia , Humanos , Método de Montecarlo , Control de Calidad , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por ComputadorRESUMEN
PURPOSE: To promote consistency in clinical trials by recommending a uniform framework as it relates to radiation transport and dose calculation in water versus in medium. METHODS: The Global Quality Assurance of Radiation Therapy Clinical Trials Harmonisation Group (GHG; www.rtqaharmonization.org) compared the differences between dose to water in water (Dw,w), dose to water in medium (Dw,m), and dose to medium in medium (Dm,m). This was done based on a review of historical frameworks, existing literature and standards, clinical issues in the context of clinical trials, and the trajectory of radiation dose calculations. Based on these factors, recommendations were developed. RESULTS: No framework was found to be ideal or perfect given the history, complexity, and current status of radiation therapy. Nevertheless, based on the evidence available, the GHG established a recommendation preferring dose to medium in medium (Dm,m). CONCLUSIONS: Dose to medium in medium (Dm,m) is the preferred dose calculation and reporting framework. If an institution's planning system can only calculate dose to water in water (Dw,w), this is acceptable.
Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Agua , Consenso , Humanos , Método de Montecarlo , Dosificación RadioterapéuticaRESUMEN
PURPOSE: The EORTC Radiation Oncology Group uses a Facility Questionnaire (FQ) to collect information from its member radiation oncology departments. We analysed the FQ database for patient-related workload, staffing levels and infrastructure to determine developments in radiation oncology departments in the clinical trials community. MATERIALS & METHODS: We exported the FQ database in August 2019. Departments were included if their FQ was created or updated within the two preceding years. Observations were compared with previous evaluations of the FQ database. RESULTS: In total, 161 departments from 24 mostly European countries were analysed. The average number of patients per department increased by 3.0% to 2,453 (2013: 2,381). The annual number of patients decreased by 7.4% to 225 per radiation oncologist (2013: 243) and by 7.9% to 326 per medical physicist (2013: 354). In contrast, the number of patients increased by 23.3% to 106 per radiation therapist (RTT) (2013: 86) and per treatment unit by 3.9 % to 485 (2013: 467). In a pairwise comparison of departments that were available in 2013 and 2019, the number of patients per radiation oncologist (p = 0.02) and per physicist (p = 0.0003) decreased significantly. The number of departments that own a dedicated PET-CT scanner more than doubled (2013: 4%; 2019: 9%) and the availability of stereotactic body radiation therapy (SBRT) increased by 31.8% to 85.7% of the departments (2013: 65%). CONCLUSION: The case-related workload per radiation oncologist and per physicist continues to decrease but increases per RTT and treatment unit. This is likely driven by an increased use of complex techniques, multimodality imaging and the implementation of automation in radiation oncology departments.
Asunto(s)
Neoplasias , Carga de Trabajo , Europa (Continente) , Humanos , Neoplasias/radioterapia , Tomografía Computarizada por Tomografía de Emisión de Positrones , Recursos HumanosRESUMEN
BACKGROUND: The relationship between the mean absorbed dose delivered to the tumour and the outcome in liver metastases from colorectal cancer patients treated with radioembolization has already been presented in several studies. The optimization of the personalized therapeutic activity to be administered is still an open challenge. In this context, how well the 99mTc-MAA SPECT/CT predicts the absorbed dose delivered by radioembolization is essential. This work aimed to analyse the differences between predictive 99mTc-MAA-SPECT/CT and post-treatment 90Y-microsphere PET/CT dosimetry at different levels. Dose heterogeneity was compared voxel-to-voxel using the quality-volume histograms, subsequently used to demonstrate how it could be used to identify potential clinical parameters that are responsible for quantitative discrepancies between predictive and post-treatment dosimetry. RESULTS: We analysed 130 lesions delineated in twenty-six patients. Dose-volume histograms were computed from predictive and post-treatment dosimetry for all volumes: individual lesion, whole tumoural liver (TL) and non-tumoural liver (NTL). For all dose-volume histograms, the following indices were extracted: D90, D70, D50, Dmean and D20. The results showed mostly no statistical differences between predictive and post-treatment dosimetries across all volumes and for all indices. Notably, the analysis showed no difference in terms of Dmean, confirming the results from previous studies. Quality factors representing the spread of the quality-volume histogram (QVH) curve around 0 (ideal QF = 0) were determined for lesions, TL and NTL. QVHs were classified into good (QF < 0.18), acceptable (0.18 ≤ QF < 0.3) and poor (QF ≥ 0.3) correspondence. For lesions and TL, dose- and quality-volume histograms are mostly concordant: 69% of lesions had a QF within good/acceptable categories (40% good) and 65% of TL had a QF within good/acceptable categories (23% good). For NTL, the results showed mixed results with 48% QF within the poor concordance category. Finally, it was demonstrated how QVH analysis could be used to define the parameters that predict the significant differences between predictive and post-treatment dose distributions. CONCLUSION: It was shown that the use of the QVH is feasible in assessing the predictive value of 99mTc-MAA SPECT/CT dosimetry and in estimating the absorbed dose delivered to liver metastases from colorectal cancer via 90Y-microspheres. QVH analyses could be used in combination with DVH to enhance the predictive value of 99mTc-MAA SPECT/CT dosimetry and to assist personalized activity prescription.
RESUMEN
The establishment of an MRI-only workflow in radiotherapy depends on the ability to generate an accurate synthetic CT (sCT) for dose calculation. Previously proposed methods have used a Generative Adversarial Network (GAN) for fast sCT generation in order to simplify the clinical workflow and reduces uncertainties. In the current paper we use a conditional Generative Adversarial Network (cGAN) framework called pix2pixHD to create a robust model prone to multicenter data. This study included T2-weighted MR and CT images of 19 patients in treatment position from 3 different sites. The cGAN was trained on 2D transverse slices of 11 patients from 2 different sites. Once trained, the network was used to generate sCT images of 8 patients coming from a third site. The Mean Absolute Errors (MAE) for each patient were evaluated between real and synthetic CTs. A radiotherapy plan was optimized on the sCT series and re-calculated on CTs to assess the dose distribution in terms of voxel-wise dose difference and Dose Volume Histograms (DVH) analysis. It takes on average of [Formula: see text] to generate a complete sCT (88 slices) for a patient on our GPU. The average MAE in HU between the sCT and actual patient CT (within the body contour) is 48.5 ± 6 HU with our method. The maximum dose difference to the target is 1.3%. This study demonstrates that an sCT can be generated in a multicentric context, with fewer pre-processing steps while being fast and accurate.
Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Pelvis/patología , Neoplasias de la Próstata/radioterapia , Neoplasias del Recto/radioterapia , Tomografía Computarizada por Rayos X/métodos , Humanos , Masculino , Estudios Multicéntricos como Asunto , Pelvis/diagnóstico por imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodosRESUMEN
PURPOSE: Reported outcomes of patients with intra-hepatic cholangiocarcinoma (IH-CCA) treated with radioembolization are highly variable, which indicates differences in included patients' characteristics and/or procedure-related variables. This study aimed to identify patient- and treatment-related variables predictive for radioembolization outcome. METHODS: This retrospective multicenter study enrolled 58 patients with unresectable and chemorefractory IH-CCA treated with resin 90Y-microspheres. Clinicopathologic data were collected from patient records. Metabolic parameters of liver tumor(s) and presence of lymph node metastasis were measured on baseline 18F-FDG-PET/CT. 99mTc-MAA tumor to liver uptake ratio (TLRMAA) was computed for each lesion on the SPECT-CT. Activity prescription using body-surface-area (BSA) or more personalized partition-model was recorded. The study endpoint was overall survival (OS) starting from date of radioembolization. Statistical analysis was performed by the log-rank test and multivariate Cox's proportional hazards model. RESULTS: Median OS (mOS) post-radioembolization of the entire cohort was 10.3 months. Variables associated with significant differences in terms of OS were serum albumin (hazard ratio (HR) = 2.78, 95%CI:1.29-5.98, p = 0.002), total bilirubin (HR = 2.17, 95%CI:1.14-4.12, p = 0.009), aspartate aminotransferase (HR = 2.96, 95%CI:1.50-5.84, p < 0.001), alanine aminotransferase (HR = 2.02, 95%CI:1.05-3.90, p = 0.01) and γ-GT (HR = 2.61, 95%CI:1.31-5.22, p < 0.001). The presence of lymph node metastasis as well as a TLRMAA < 1.9 were associated with shorter mOS: HR = 2.35, 95%CI:1.08-5.11, p = 0.008 and HR = 2.92, 95%CI:1.01-8.44, p = 0.009, respectively. Finally, mOS was significantly shorter in patients treated according to the BSA method compared to the partition-model: mOS of 5.5 vs 14.9 months (HR = 2.52, 95%CI:1.23-5.16, p < 0.001). Multivariate analysis indicated that the only variable that increased outcome prediction above the clinical variables was the activity prescription method with HR of 2.26 (95%CI:1.09-4.70, p = 0.03). The average mean radiation dose to tumors was significantly higher with the partition-model (86Gy) versus BSA (38Gy). CONCLUSION: Radioembolization efficacy in patients with unresectable recurrent and/or chemorefractory IH-CCA strongly depends on the tumor radiation dose. Personalized activity prescription should be performed.