RESUMEN
AIMS: Patients with aortic stenosis (AS) and cardiogenic shock (CS) are an extremely high-risk population with a poor prognosis in the absence of definitive therapy. We aimed to compare the outcomes of transcatheter aortic valve replacement (TAVR) with those of surgical aortic valve replacement (SAVR) in patients with AS-CS. METHODS AND RESULTS: We queried the Nationwide Readmission Database (2016-21) to identify patients hospitalized for AS-CS who underwent isolated TAVR or SAVR. In-hospital outcomes of TAVR vs. SAVR were compared using multivariable regression and propensity-matching analyses. Ninety-day readmissions were compared using a Cox proportional hazards regression model. A total of 16 161 patients were hospitalized for AS-CS, of whom 6470 (40.0%) underwent isolated TAVR and 9691 (60.0%) underwent isolated SAVR. From 2016 through 2021, the proportion of TAVR increased from 29.5 to 46.5% and the proportion of SAVR correspondingly decreased in AS-CS (Ptrend < 0.01). After adjustment for baseline characteristics, TAVR was associated with lower odds of stroke [adjusted odds ratio (aOR) 0.63, 95% confidence interval (CI) 0.47-0.84], acute kidney injury (aOR 0.80, 95% CI 0.69-0.93), and major bleeding (aOR 0.54, 95% CI 0.40-0.71) and higher odds of vascular complications (aOR 1.56, 95% CI 1.23-1.97) compared with SAVR. In-hospital mortality, myocardial infarction, permanent pacemaker placement, and 90-day all-cause and heart failure readmissions showed similar rates between TAVR and SAVR. However, hospital length of stay was shorter and total costs and non-home discharges were lower with TAVR than with SAVR. CONCLUSION: This nationwide observational analysis showed that TAVR is increasingly performed in patients with AS-CS and is associated with similar rates of in-hospital mortality and 90-day readmissions but lower rates of in-hospital complications and resource utilization compared with SAVR.
Asunto(s)
Estenosis de la Válvula Aórtica , Mortalidad Hospitalaria , Choque Cardiogénico , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Choque Cardiogénico/epidemiología , Choque Cardiogénico/etiología , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Anciano , Anciano de 80 o más Años , Mortalidad Hospitalaria/tendencias , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Readmisión del Paciente/estadística & datos numéricos , Readmisión del Paciente/tendencias , Estados Unidos/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo , Resultado del Tratamiento , Tasa de Supervivencia/tendencias , Válvula Aórtica/cirugíaRESUMEN
Objective: To evaluate whether major adverse cardiac events (MACE) continue to be a major causative factor for mortality after noncardiac surgery. Patients and Methods: We performed retrospective study of 75,410 adult noncardiac surgery patients at Mayo Clinic Rochester, between January 1, 2016, and May 4, 2018. Electronic medical records were reviewed and data collected on all deaths within 30 days (n=692 patients) of surgery. The incidence of death due to MACE was calculated. Results: Postoperative MACE occurred in 150 patients (21.4 events per 10,000 patients; 95% CI, 18.2-25.2 events per 10,000 patients) with most occurring within 3 days of surgery (n=113). Postoperative MACE events were associated with atrial fibrillation with rapid rate response in 25 patients (16.7%), sepsis in 15 patients (10%), and bleeding in 15 patients (10%). There were 12 intraoperative deaths of which 9 were due to exsanguination (75%) and the remaining 3 (25%) due to cardiac arrest. Of the 56 deaths on the first 24 hours after surgery, 7 were due to hemorrhage, 17 due to cardiovascular causes, 20 due to sepsis, and 7 due to neurologic disease. The leading cause of total death over 30 days postoperatively was sepsis (28%), followed by malignancy (27%), cardiovascular disease (12%) neurologic disease (12%), and hemorrhage (5%). Conclusion: MACE was not the leading cause of death both intraoperatively and postoperatively.
RESUMEN
Background: Conduction disease is an important and common complication post-transcatheter aortic valve replacement (TAVR). Previously, we developed a conduction disease risk stratification and management protocol post-TAVR. This study aims to evaluate high-grade aortic valve block (HAVB) incidence and risk factors in a large cohort undergoing ambulatory cardiac monitoring post-TAVR according to conduction risk grouping. Methods: This single-center, retrospective study evaluated all patients discharged on ambulatory cardiac monitoring between 2016 and 2021 and stratified them into 3 groups based on electrocardiogram predictors of HAVB risk (group 1 [low], group 2 [intermediate], and group 3 [high]). HAVB was defined as ≥2 consecutive nonconducted P waves in sinus rhythm or bradycardia <50 beats/minute with a fixed rate for atrial fibrillation/flutter. Descriptive statistics were used to show the incidence and timeline, while logistic regression was utilized to evaluate predictors of HAVB. Results: Five hundred twenty-eight patients were included (median age 80 years [74-85]; 43.8% female). Forty-one patients (7.8%) developed HAVB during ambulatory monitoring (68% were asymptomatic). Over a median follow-up of 2 years (1.3-2.7), the overall mortality rate was 15.0% (30-day mortality rate of 0.57%, n = 3). Risk factors for HAVB were male sex (odds ratio [OR] = 2.46, p = 0.02, 95% CI = 1.21-5.43), baseline right bundle branch block (OR = 2.80, p = 0.01, 95% CI = 1.17-6.19), and post-TAVR QRS >150 âms (OR = 2.16, p = 0.03, 95% CI = 1.01-4.40). The negative predictive value for patients in groups 1 and 2 for 30-day HAVB was 95.0 and 93.8%, respectively. Conclusions: The risk of 30-day HAVB post-TAVR on ambulatory monitoring post-TAVR varies according to post-TAVR electrocardiogram findings, and a 3-group algorithm effectively identifies groups with a low negative predictive value for HAVB.
RESUMEN
BACKGROUND: Previous transcatheter valve therapy registry analyses of transcatheter mitral valve in valve (MViV) replacement of degenerated bioprosthesis reported early experience in the United States. Given recent increases in transseptal MViV volumes and introduction of the SAPIEN 3 Ultra valve, it is important to determine contemporary outcomes for patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV replacement. METHODS: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry was used to extract data for all patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV from 2015 to September 2022. Primary efficacy outcome was 1-year all-cause mortality. Secondary end points included 30-day mortality, functional class, quality of life, and mitral valve performance. Primary safety outcomes were device success and in-hospital complications. RESULTS: A total of 4243 patients with a mean STS score of 9.2±7.7 underwent transseptal MViV at 455 sites. The rate of Mitral Valve Academic Research Consortium technical (96.6%) success was high, and procedural complications were low. All-cause in-hospital, 30-day, and 1-year mortality rates were 3.2%, 4.3%, and 13.4%, respectively. Significant improvements in New York Heart Association class (New York Heart Association I/II, 18% to 87%) and quality of life (Kansas City Cardiomyopathy Questionnaire score, 38 to 78) were noted at 1 year (P<0.0001 for both) after MViV. Upon stratifying by STS scores, it was observed that the low-risk group (STS<4) had a significantly lower in-hospital mortality rate of 0.4%, whereas the intermediate-risk group (STS, 4-8) had an in-hospital mortality rate of 1.9%. From 2015 to 2022, the number of transseptal MViV cases/year increased significantly, whereas procedure times, length of stay, and intensive care unit hours shortened significantly. At the same time, there was a significant trend toward reduced in-hospital (P=0.0005), 30-day (P=0.004), and 1-year mortality rates (P=0.01). CONCLUSIONS: This multicenter, prospective study reports excellent procedural outcomes, 1-year mortality rates, and a significant improvement in quality of life for patients undergoing transseptal MViV in the contemporary era. Patients in the low-risk and intermediate-risk STS score categories had significantly better outcomes compared with those in the high-risk category. MViV is a reasonable therapy for the majority of patients with degenerated bioprosthetic mitral valves, who are anatomical candidates.
RESUMEN
BACKGROUND: A significant proportion of patients requiring mitral valve (MV) intervention have undergone prior coronary artery bypass grafting (CABG). Reoperative heart surgery is associated with increased risk. AIMS: To evaluate the utilization and outcomes of transcatheter versus surgical MV interventions in patients with prior CABG. METHODS: We queried the Nationwide Readmission Database (2016-2021) to identify adults with prior CABG hospitalized for transcatheter or surgical MV intervention. In-hospital outcomes were compared using multivariable regression and propensity-matching analyses. Readmissions were compared using Cox proportional hazards regression model. RESULTS: Of 305,625 weighted hospitalizations for MV intervention, 23,506 (7.7%) occurred in patients with prior CABG. From 2016-2021, the use of transcatheter MV interventions increased among patients with prior CABG (72 to 191 for repair and 6 to 45 for replacement per 100,000 hospitalizations, both ptrend<0.001). Compared with surgical MV repair and replacement, transcatheter MV repair and replacement were associated with similar in-hospital mortality (adjusted odds ratio [aOR] 0.44, 95% confidence interval [CI] 0.20-1.03 for repair; aOR 0.61, 95% CI 0.38-1.02 for replacement) and 180-day heart failure readmissions (adjusted hazard ratio [aHR] 1.56, 95% CI 0.85-2.87 for repair; aHR 1.15, 95% CI 0.63-2.09 for replacement) and lower stroke, acute kidney injury, permanent pacemaker placement, length of stay, and nonhome discharges, respectively. Vascular complications were higher with transcatheter versus surgical MV replacement. CONCLUSIONS: Transcatheter MV interventions are increasingly used as the preferred modality of MV intervention in patients with prior CABG and are associated with similar in-hospital mortality and 180-day heart failure readmissions compared with surgical MV interventions.
RESUMEN
BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Cateterismo Cardíaco/métodosAsunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de PrótesisRESUMEN
BACKGROUND: Data on the prognostic factors after mitral valve (MV) transcatheter edge-to-edge repair (TEER; MV-TEER) are limited. Pulsed-wave Doppler interrogation of pulmonary vein flow (PVF) is a convenient method to assess the hemodynamic burden of residual mitral regurgitation (MR), which could be of utility as a predictor of outcomes. METHODS: Patients that underwent MV-TEER between May 2014 and December 2021 at our institution were evaluated. Pulmonary vein flow patterns post-MV-TEER were reviewed on the procedural transesophageal echocardiogram and classified as normal (systolic dominant or codominant) or abnormal (systolic blunting or reversal). The PVF pattern was correlated with all-cause mortality at follow-up. RESULTS: Two-hundred sixty-five patients had diagnostic PVF post-MV-TEER, with 73 (27.5%) categorized as normal and 192 (72.5%) categorized as abnormal. Patients with abnormal PVF morphology were more likely to have atrial fibrillation (70% vs 42%, P < .001) and greater than moderate residual MR (16% vs 3%, P = .01) and had higher mean left atrial pressure (18.1 ± 5.0 vs 15.9 ± 4.2 mm Hg, P = .002) and left atrial V wave (26.6 ± 8.5 vs 21.4 ± 7.3 mm Hg, P < .001) postprocedure. In multivariable analysis, abnormal PVF morphology post-MV-TEER was independently associated with mortality at follow-up (hazard ratio = 1.70; 95% CI, 1.06-2.74; P = .03) after correction for end-stage renal disease, atrial fibrillation, and residual MR. Results were similar in subgroups of patients with moderate or less and those with mild or less residual MR. CONCLUSIONS: Pulmonary vein flow morphology is a simple and objective tool to assess MR severity immediately post-MV-TEER and offers important prognostic information to optimize procedural results. Additional studies are needed to determine whether patients with abnormal PVF pattern post-MV-TEER would benefit from more intensive goal-directed medical therapy postprocedure.
Asunto(s)
Cateterismo Cardíaco , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Mitral , Válvula Mitral , Venas Pulmonares , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Masculino , Femenino , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anciano , Ecocardiografía Transesofágica/métodos , Cateterismo Cardíaco/métodos , Estudios Retrospectivos , Tasa de Supervivencia , Pronóstico , Ecocardiografía Doppler de Pulso/métodosAsunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Objetivos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo CardíacoRESUMEN
BACKGROUND AND AIMS: The incidence and outcomes of high bleeding risk (HBR) patients in a community cohort according to the Academic Research Consortium (ARC) criteria is not known. We hypothesized that HBR is common and associated with worse outcomes for all-comers with myocardial infarction. METHODS: We prospectively collected all patients with cardiac troponin T > 99th percentile upper limit of normal (≥0.01 ng/mL) in Olmsted County between 2003 and 2012. Events were retrospectively classified as type 1 myocardial infarction (T1MI), type 2 myocardial infarction (T2MI), or myocardial injury. Patients were further classified as HBR based on the "ARC-HBR definition." Outcomes included all-cause mortality, cardiovascular mortality, recurrent MI, stroke, and major bleeding. RESULTS: 2419 patients were included in the final study; 1365 were classified as T1MI and 1054 as T2MI. Patients were followed for a median of 5.5 years. ARC-HBR was more common in T2MI than T1MI (73% vs 46%, p < 0.001). Among patients with T1MI, HBR was associated with higher all-cause mortality (HR 3.7, 95% CI 3.2-4.5, p < 0.001), cardiovascular mortality (4.7, 3.6-6.3, p < 0.001), recurrent MI (2.1, 1.6-2.7, p < 0.001), stroke (4.9, 2.9-8.4, p < 0.001), and major bleeding (6.5, 3.7-11.4, p < 0.001). For T2MI, HBR was similarly associated with higher all-cause mortality (HR 2.1, 95% CI 1.8-2.5, p < 0.001), cardiovascular mortality (2.7, 1.8-4.0, p < 0.001), recurrent MI (1.7, 1.1-2.6, p = 0.02) and major bleeding (HR 15.6, 3.8-63.8, p < 0.001). CONCLUSION: HBR is common among unselected patients with T1MI and T2MI and is associated with increased overall and cardiovascular mortality, recurrent cardiovascular events, and major bleeding on long-term follow up.
Asunto(s)
Infarto de la Pared Anterior del Miocardio , Infarto del Miocardio , Intervención Coronaria Percutánea , Accidente Cerebrovascular , Humanos , Estudios Retrospectivos , Incidencia , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Infarto del Miocardio/complicaciones , Infarto de la Pared Anterior del Miocardio/complicaciones , Hemorragia/diagnóstico , Hemorragia/epidemiología , Hemorragia/inducido químicamente , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/inducido químicamente , Inhibidores de Agregación Plaquetaria/efectos adversos , Resultado del Tratamiento , Factores de RiesgoAsunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversosRESUMEN
BACKGROUND: Alcohol septal ablation (ASA) is a minimally invasive treatment for drug-refractory obstructive hypertrophic cardiomyopathy. Detailed assessment of pressure changes and predictors of mortality and procedure success are not well defined. METHODS: This is a single-center study evaluating pressure changes and predictors of mortality and procedure success in transseptal ASA. Survival analysis and predictors of mortality were assessed using the Kaplan-Meier analysis and Cox regression, respectively. RESULTS: A total of 156 patients were included (mean age, 67.3 years; 46.8% women). Left atrial (LA) pressure and left ventricular outflow tract (LVOT) gradient decreased, whereas aortic pulse pressure (PP) increased post-ASA. Patients with lower baseline mean LA pressure (Asunto(s)
Técnicas de Ablación
, Procedimientos Quirúrgicos Cardíacos
, Cardiomiopatía Hipertrófica
, Humanos
, Femenino
, Anciano
, Masculino
, Resultado del Tratamiento
, Etanol/efectos adversos
, Cardiomiopatía Hipertrófica/diagnóstico por imagen
, Cardiomiopatía Hipertrófica/cirugía
, Hemodinámica
, Técnicas de Ablación/efectos adversos
RESUMEN
BACKGROUND: Ischemic stroke (IS) is an uncommon but severe complication in patients undergoing percutaneous coronary intervention (PCI). Despite significant morbidity and economic cost associated with post PCI IS, a validated risk prediction model is not currently available. AIMS: We aim to develop a machine learning model that predicts IS after PCI. METHODS: We analyzed data from Mayo Clinic CathPCI registry from 2003 to 2018. Baseline clinical and demographic data, electrocardiography (ECG), intra/post-procedural data, and echocardiographic variables were abstracted. A random forest (RF) machine learning model and a logistic regression (LR) model were developed. The receiver operator characteristic (ROC) analysis was used to assess model performance in predicting IS at 6-month, 1-, 2-, and 5-years post-PCI. RESULTS: A total of 17,356 patients were included in the final analysis. The mean age of this cohort was 66.9 ± 12.5 years, and 70.7% were male. Post-PCI IS was noted in 109 patients (.6%) at 6 months, 132 patients (.8%) at 1 year, 175 patients (1%) at 2 years, and 264 patients (1.5%) at 5 years. The area under the curve of the RF model was superior to the LR model in predicting ischemic stroke at 6 months, 1-, 2-, and 5-years. Periprocedural stroke was the strongest predictor of IS post discharge. CONCLUSIONS: The RF model accurately predicts short- and long-term risk of IS and outperforms logistic regression analysis in patients undergoing PCI. Patients with periprocedural stroke may benefit from aggressive management to reduce the future risk of IS.
Asunto(s)
Accidente Cerebrovascular Isquémico , Intervención Coronaria Percutánea , Accidente Cerebrovascular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Intervención Coronaria Percutánea/efectos adversos , Inteligencia Artificial , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/epidemiología , Accidente Cerebrovascular Isquémico/etiología , Cuidados Posteriores , Alta del Paciente , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Riesgo , Sistema de Registros , Resultado del Tratamiento , Medición de RiesgoRESUMEN
BACKGROUND: The financial burden linked to the diagnosis and treatment of patients with chest pain on the health care system is considerable. Angina and nonobstructive coronary artery disease (ANOCA) is common, associated with adverse cardiovascular events, and may lead to repeat testing or hospitalizations. Diagnostic certainty can be achieved in patients with ANOCA using coronary reactivity testing (CRT); however, its financial effect on the patient has not been studied. Our goal was to assess the effect of CRT on health care-related cost in patients with ANOCA. METHODS: Patients with ANOCA who underwent diagnostic coronary angiography (CAG) and CRT (CRT group) were matched to controls who had similar presentation but only underwent a CAG without CRT (CAG group). Standardized inflation-adjusted costs were collected and compared between the 2 groups on an annual basis for 2 years post the index date (CRT or CAG). RESULTS: Two hundred seven CRT and 207 CAG patients were included in the study with an average age of 52.3±11.5 years and 76% females. The total cost was significantly higher in the CAG group as compared with the CRT group ($37 804 [$26 933-$48 674] versus $13 679 [$9447-$17 910]; P<0.001). When costs are itemized and divided based on the Berenson-Eggers Type of Service categorization, the largest cost difference occurred in imaging (any type, including CAG; P<0.001), procedures (eg, percutaneous coronary intervention/coronary artery bypass grafting/thrombectomy) (P=0.001), and test (eg, blood tests, EKG; P<0.001). CONCLUSIONS: In this retrospective observational study, assessment of CRT in patients with ANOCA was associated with significantly reduced annual total costs and health care utilization. Therefore, the study may support the integration of CRT into clinical practice.
Asunto(s)
Enfermedad de la Arteria Coronaria , Femenino , Humanos , Adulto , Persona de Mediana Edad , Masculino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Resultado del Tratamiento , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/etiología , Angiografía Coronaria , Costos de la Atención en SaludRESUMEN
Background: Severe tricuspid regurgitation (TR) is associated with considerable morbidity/mortality in an elderly population with multiple comorbidities. There is interest in transcatheter interventions to manage severe TR. Understanding complex right heart (RH) geometry and tricuspid valve shape and size has implications for patient/device selection for transcatheter intervention. We characterized RH anatomy by computed tomography in patients with symptomatic severe TR considered for intervention. Methods: The retrospective Mayo Clinic study included 29 patients with an echocardiogram and cardiac computed tomography angiogram considered for intervention of severe TR from March 01, 2016 to December 15, 2020. Patients were divided into 2 groups: intervention (surgical or transcatheter; n = 17) and medical management alone (n = 12). Results: Mean age was 83 ± 8 (83% female), 100% had atrial fibrillation, and 62% had chronic kidney disease ≥3a. Ninety-seven percent were symptomatic, 93% had been prescribed loop diuretics, and 24% had device leads. Mean tricuspid annular plane systolic excursion was 16.8 ± 4.5 mm, effective regurgitant orifice area was 81 ± 33 mm2, and cardiac index was 2.6 ± 0.6 L/min/m2. Forty-one percent had at least moderate right ventricular (RV) dysfunction with a mean RV systolic pressure of 46 ± 16 mmHg. Patients receiving intervention had significantly larger effective regurgitant orifice area (101 ± 33 vs. 63 ± 22 mm2, p = 0.033), shorter tricuspid leaflet tenting length (6.5 ± 3.0 vs. 8.9 ± 2.7 mm, p = 0.042), and smaller annuloplasty diagnostic perimeter during diastole (120.1 ± 16.6 vs. 131.1 ± 7.4 mm, p = 0.041). Intervention patients tended to have better right ventricular function, smaller RV and inferior vena cava size, and more severe symptoms. The maximal tricuspid annulus diameter in systole and diastole was 51 ± 5 and 53 ± 7 mm, respectively. Conclusions: Severe TR patients referred for transcatheter intervention present with severe RH enlargement with a large proportion having tricuspid annulus dimensions outside the range for current devices available in clinical trials. The presented data have implications for device development/selection and procedural feasibility.
RESUMEN
BACKGROUND: Transcatheter tricuspid valve edge-to-edge repair (TTEER) is associated with improvement in outcomes for symptomatic patients with severe tricuspid regurgitation (TR). However, reliable predictors for clinical success are not yet fully defined. This study aims to describe right heart catheterization (RHC) findings in patients referred for TTEER and identify hemodynamic characteristics of patients who experience immediate symptomatic improvement following successful TR intervention. METHODS: Patients who underwent TTEER and had a separate RHC within the preceding 6 months were included. Hemodynamic tracings from the RHC and TTEER procedures were reviewed and recorded. Clinical success was defined as a successful device implant with at least 1-grade of TR reduction and improvement in NYHA class by 1 or more grades on 30-day echocardiogram and clinical follow-up. RESULTS: Thirteen patients underwent an RHC within 6 months of TTEER procedure (median age 76 years [IQR: 73-80]). All patients were on a stable dose of loop diuretics. Baseline right atrial pressure was severely elevated (mean 19 mmHg [IQR: 9-24 mmHg]) with prominent CV waves. Median pulmonary capillary wedge pressure (PCWP) was 20 mmHg (IQR: 14-22) and 70% of patients had a mean PCWP > 15 mmHg at rest. Median PCWP CV-wave was 34 mmHg (IQR: 23-42). Higher PCWP CV-wave height (40 mmHg [IQR 33-43] versus 18 mmHg [IQR 17-31]) was associated with lower likelihood of clinical success (OR 0.83, 95% CI: 0.35-0.97, p = 0.04). CONCLUSIONS: Inclusion of invasive hemodynamics as part of pre-TTEER evaluation may allow for improved TR phenotyping and patient selection. Patients with a large left atrial CV wave on resting RHC were less likely to experience immediate symptomatic improvement despite procedural success with TTEER.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Anciano , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Cateterismo CardíacoRESUMEN
BACKGROUND: Identifying predictors of readmissions after mitral valve transcatheter edge-to-edge repair (MV-TEER) is essential for risk stratification and optimization of clinical outcomes. AIMS: We investigated the performance of machine learning [ML] algorithms vs. logistic regression in predicting readmissions after MV-TEER. METHODS: We utilized the National-Readmission-Database to identify patients who underwent MV-TEER between 2015 and 2018. The database was randomly split into training (70 %) and testing (30 %) sets. Lasso regression was used to remove non-informative variables and rank informative ones. The top 50 informative predictors were tested using 4 ML models: ML-logistic regression [LR], Naive Bayes [NB], random forest [RF], and artificial neural network [ANN]/For comparison, we used a traditional statistical method (principal component analysis logistic regression PCA-LR). RESULTS: A total of 9425 index hospitalizations for MV-TEER were included. Overall, the 30-day readmission rate was 14.6 %, and heart failure was the most common cause of readmission (32 %). The readmission cohort had a higher burden of comorbidities (median Elixhauser score 5 vs. 3) and frailty score (3.7 vs. 2.9), longer hospital stays (3 vs. 2 days), and higher rates of non-home discharges (17.4 % vs. 8.5 %). The traditional PCA-LR model yielded a modest predictive value (area under the curve [AUC] 0.615 [0.587-0.644]). Two ML algorithms demonstrated superior performance than the traditional PCA-LR model; ML-LR (AUC 0.692 [0.667-0.717]), and NB (AUC 0.724 [0.700-0.748]). RF (AUC 0.62 [0.592-0.677]) and ANN (0.65 [0.623-0.677]) had modest performance. CONCLUSION: Machine learning algorithms may provide a useful tool for predicting readmissions after MV-TEER using administrative databases.
Asunto(s)
Hospitalización , Readmisión del Paciente , Humanos , Teorema de Bayes , Algoritmos , Aprendizaje AutomáticoRESUMEN
BACKGROUND: Improvement in left atrial pressure (LAP) during transcatheter edge-to-edge repair (TEER) is associated with improved outcomes. We sought to investigate the predictors of optimal hemodynamic response to TEER. METHODS: We identified patients who underwent TEER at Mayo Clinic between May 2014 and February 2022. Patients with missing LAP data, an aborted procedure, and those undergoing a concomitant tricuspid TEER were excluded. We performed a logistic regression analysis to identify predictors of optimal hemodynamic response to TEER (defined as LAP ≤ 15 mmHg). RESULTS: A total of 473 patients were included (Mean age 78.5 ± 9.4 years, 67.2% males). Overall, 195 (41.2%) achieved an optimal hemodynamic response after TEER. Patients who did not achieve an optimal response had higher baseline LAP (20.0 [17-25] vs. 15.0 [12-18] mmHg, p < 0.001), higher prevalence of AF (68.3% vs. 55.9%, p = 0.006), functional MR (47.5% vs. 35.9%, p = 0.009), annular calcification (41% vs. 29.2%, p = 0.02), lower left ventricular EF (55% vs. 58%, p = 0.02), and more frequent postprocedural severe MR (11.9% vs. 5.1%, p = 0.02) and elevated mitral gradient >5 mmHg (30.6% vs. 14.4%, p < 0.001). In the multivariate logistic regression analysis, AF (OR = 0.58; 95% CI = 0.35-0.96; p = 0.03), baseline LAP (OR = 0.80; 95% CI = 0.75-0.84; p < 0.001) and postprocedural mitral gradient <5 mmHg (OR = 0.35; 95% CI = 0.19-0.65; p < 0.001), were independent predictors of achieving an optimal hemodynamic response. In the multivariate model, residual MR was not independently associated with optimal hemodynamic response. CONCLUSIONS: Optimal hemodynamic response is achieved in 4 in 10 patients undergoing TEER. AF, higher baseline LAP, and higher postprocedural mitral gradient were negative predictors of optimal hemodynamic response after TEER.
Asunto(s)
Calcinosis , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Resultado del Tratamiento , Hemodinámica , Ventrículos Cardíacos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversosRESUMEN
An increasing number of patients with mitral valve disease are high risk for surgery and in need of less invasive treatments including transcatheter mitral valve replacement (TMVR). Left ventricular outflow tract (LVOT) obstruction is a predictor of poor outcome after TMVR, and its risk can be accurately predicted using cardiac computed tomography analysis. Novel treatment strategies that have shown efficacy in reducing risk of LVOT obstruction after TMVR include pre-emptive alcohol septal ablation, radiofrequency ablation, and anterior leaflet electrosurgical laceration. This review describes recent advances in the management of LVOT obstruction risk after TMVR, provides a new management algorithm, and explores forthcoming studies that will further advance the field.