Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Asthma ; 61(9): 970-975, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38323583

RESUMEN

INTRODUCTION: One of the fundamental challenges of managing patients with severe asthma is treatment adherence, particularly with inhaled corticosteroids. Adherence is difficult to measure objectively and poor adherence is associated with worse outcomes. In this study, assess the ability of a 'smart' inhaler to record adherence in severe asthma patients and measure the impact of this on asthma control. METHODS: Consecutive consenting patients meeting criteria for biologics had their existing high-dose ICS/LABA//LAMA combination inhaler/s switched to mometasone/indacaterol/glycopyrronium (114/46/136). Routine clinical data, including blood eosinophils, FeNO, and ACQ-6 scores were collected at baseline and at 4 wk. Adherence was then checked on the Propeller Health app, and good adherence was defined as >80% of prescribed usage. Participants were then followed-up at 12 months to record the proportion of patients who were initiated on biologics. RESULTS: 77 patients (mean [SD] age = 50.4 [15.7] years, 67.5% female [n = 52]) participated. 71 participants were able to use the device and 65% (n = 46) of these attained good asthma control and were not initiated on biologics at 12-month follow-up. Both groups demonstrated a significant reduction in ACQ6 score at follow-up (2.81 vs. 1.92, p < 0.001 and 3.05 vs. 2.60, p < 0.001, respectively), but there was no statistically significant difference in improvement between groups. Patients with optimal adherence also demonstrated a significant reduction in median FeNO at follow-up (47 ppb vs. 40 ppb, p = 0.003). CONCLUSIONS: In severe asthma patients, 'smart' inhalers may represent an effective management tool to improve adherence and asthma control, therefore avoiding the need for patients to commence biological therapies.


Asunto(s)
Antiasmáticos , Asma , Cumplimiento de la Medicación , Humanos , Asma/tratamiento farmacológico , Femenino , Masculino , Persona de Mediana Edad , Adulto , Cumplimiento de la Medicación/estadística & datos numéricos , Administración por Inhalación , Antiasmáticos/administración & dosificación , Antiasmáticos/uso terapéutico , Quinolonas/administración & dosificación , Indanos/administración & dosificación , Glicopirrolato/administración & dosificación , Glicopirrolato/uso terapéutico , Nebulizadores y Vaporizadores , Índice de Severidad de la Enfermedad , Furoato de Mometasona/administración & dosificación , Furoato de Mometasona/uso terapéutico , Anciano , Combinación de Medicamentos , Corticoesteroides/administración & dosificación , Corticoesteroides/uso terapéutico
2.
Am J Perinatol ; 38(S 01): e92-e101, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32120418

RESUMEN

OBJECTIVE: This study aimed to establish neonatal serum triglyceride (TG) level reference ranges during lipid infusion and correlate peak TG with neonatal outcomes. STUDY DESIGN: This is a retrospective review of 356 neonates with 696 TG measures obtained in four neonatal intensive care units between 2015 and 2017. TG was evaluated collectively to establish a reference range and a threshold limit. To analyze the effects of a higher TG threshold, neonates were categorized by their peak TG: <180 (TG<180), 180 to 400 (TG180-400), and > 400 mg/dL (TG>400). Univariable and multivariable regression models were constructed to compare peak TG to patient characteristic and clinical outcomes. RESULTS: The frequency of TG > 400 mg/dL was 5% and found only in neonates weighing < 1.5 kg. Neonates in the TG180-400 (n = 91) group were significantly lower in birth weight and gestational age, had lower 5-minute APGAR scores, and had increased ventilatory requirement when compared with neonates in the TG<180 (n = 240) group (all p < 0.001). The TG180-400 group had increased risk of severe intraventricular hemorrhage (p = 0.02) and bronchopulmonary dysplasia (p = 0.03). Elevated TG was associated with mortality (odds ratio [OR]: 14.4, p < 0.001) in univariable analysis, but the relationship weakened (OR: 4.4, p = 0.05) after adjusting for comorbidities in multivariable logistic regression. CONCLUSION: It is unclear if the adverse outcomes seen in neonates with higher peak TG were due to elevated TG alone, or whether illness severity predicted the increased TG. More prospective studies are needed to further delineate the relationships.


Asunto(s)
Emulsiones Grasas Intravenosas , Hipertrigliceridemia/mortalidad , Recién Nacido/sangre , Nutrición Parenteral , Triglicéridos/sangre , Peso al Nacer , Displasia Broncopulmonar/sangre , Displasia Broncopulmonar/etiología , Hemorragia Cerebral Intraventricular/sangre , Hemorragia Cerebral Intraventricular/etiología , Emulsiones Grasas Intravenosas/administración & dosificación , Emulsiones Grasas Intravenosas/efectos adversos , Femenino , Edad Gestacional , Humanos , Hipertrigliceridemia/complicaciones , Recién Nacido Pequeño para la Edad Gestacional , Unidades de Cuidado Intensivo Neonatal , Modelos Logísticos , Masculino , Oportunidad Relativa , Valores de Referencia , Estudios Retrospectivos , Factores de Riesgo , Triglicéridos/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...