Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Radiat Environ Biophys ; 59(3): 357-387, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32372284

RESUMEN

This work presents an overview of the applications of retrospective dosimetry techniques in case of incorporation of radionuclides. The fact that internal exposures are characterized by a spatially inhomogeneous irradiation of the body, which is potentially prolonged over large periods and variable over time, is particularly problematic for biological and electron paramagnetic resonance (EPR) dosimetry methods when compared with external exposures. The paper gives initially specific information about internal dosimetry methods, the most common cytogenetic techniques used in biological dosimetry and EPR dosimetry applied to tooth enamel. Based on real-case scenarios, dose estimates obtained from bioassay data as well as with biological and/or EPR dosimetry are compared and critically discussed. In most of the scenarios presented, concomitant external exposures were responsible for the greater portion of the received dose. As no assay is available which can discriminate between radiation of different types and different LETs on the basis of the type of damage induced, it is not possible to infer from these studies specific conclusions valid for incorporated radionuclides alone. The biological dosimetry assays and EPR techniques proved to be most applicable in cases when the radionuclides are almost homogeneously distributed in the body. No compelling evidence was obtained in other cases of extremely inhomogeneous distribution. Retrospective dosimetry needs to be optimized and further developed in order to be able to deal with real exposure cases, where a mixture of both external and internal exposures will be encountered most of the times.


Asunto(s)
Radiación Ionizante , Radiometría/métodos , Animales , Espectroscopía de Resonancia por Spin del Electrón , Humanos , Radioisótopos/farmacocinética
2.
Radiat Prot Dosimetry ; 164(1-2): 42-5, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25205835

RESUMEN

Creating a sustainable network in biological and retrospective dosimetry that involves a large number of experienced laboratories throughout the European Union (EU) will significantly improve the accident and emergency response capabilities in case of a large-scale radiological emergency. A well-organised cooperative action involving EU laboratories will offer the best chance for fast and trustworthy dose assessments that are urgently needed in an emergency situation. To this end, the EC supports the establishment of a European network in biological dosimetry (RENEB). The RENEB project started in January 2012 involving cooperation of 23 organisations from 16 European countries. The purpose of RENEB is to increase the biodosimetry capacities in case of large-scale radiological emergency scenarios. The progress of the project since its inception is presented, comprising the consolidation process of the network with its operational platform, intercomparison exercises, training activities, proceedings in quality assurance and horizon scanning for new methods and partners. Additionally, the benefit of the network for the radiation research community as a whole is addressed.


Asunto(s)
Bioensayo/métodos , Planificación en Desastres/organización & administración , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Liberación de Radiactividad Peligrosa/prevención & control , Urgencias Médicas , Europa (Continente) , Humanos , Exposición a la Radiación/prevención & control , Administración de la Seguridad/organización & administración
3.
Radiat Prot Dosimetry ; 155(4): 418-22, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23460030

RESUMEN

In 2011, a serious radiation accident occurred in Stamboliyski, Bulgaria, in an industrial sterilisation facility using very-high-activity (60)Co sources. For the five persons accidentally exposed, biological dosimetry based on dicentric analysis was performed in Sofia and in Paris, where the patients were transferred for treatment. Before completing the chromosomal dose assessment, and for the most exposed person, a preliminary cytogenetic evaluation based on electronically transmitted metaphase images was made. The averaged acute whole-body dose estimates for the five patients ranged from 5.2 to 1.2 Gy, and good agreement was obtained between the two laboratories. The patients were also assessed by their prodromal responses and depressed blood cell counts over the first week. The cytogenetic dose estimates were in good accord with those derived from the blood counts, and both techniques indicated that, for the two most seriously exposed persons both techniques indicated that the initial prodromal reactions had suggested somewhat less severe exposure.


Asunto(s)
Liberación de Radiactividad Peligrosa , Radiometría/métodos , Adulto , Anciano , Bulgaria , Aberraciones Cromosómicas , Radioisótopos de Cobalto , Relación Dosis-Respuesta en la Radiación , Femenino , Rayos gamma , Humanos , Linfocitos/efectos de la radiación , Masculino , Persona de Mediana Edad , Dosis de Radiación , Radiometría/instrumentación
4.
Radiat Prot Dosimetry ; 151(1): 135-43, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22234421

RESUMEN

Fundamentals of biological dosimetry are described in the International Atomic Energy Agency manual, but all over the world each laboratory is using its own protocol. To test the influence of protocol variations, some blood samples were exposed to 0.5 Gy of gamma radiation and mitotic index and dicentric rates were measured under different experimental conditions. The effect of seven parameters [bromodeoxyuridin (BrdU), phytohaemagglutinin and colcemid concentrations, blood and medium volumes, culture duration and incubation temperature] was tested using a Placket and Burman experimental design. The analysis reveals that the mitotic index was influenced by the concentration of BrdU, medium and blood volumes, the culture duration and the temperature. However, none of the factors has a significant impact on the yield of dicentrics. The dicentric assay is robust against reagent variations within the range tested. These results could be used by relevant laboratories as elements of their procedures robustness in any event requiring such demonstration.


Asunto(s)
Aberraciones Cromosómicas/efectos de la radiación , Rayos gamma/efectos adversos , Linfocitos/efectos de la radiación , Índice Mitótico , Células Cultivadas , Relación Dosis-Respuesta en la Radiación , Humanos , Radiometría
5.
Br J Radiol ; 83(993): 759-66, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20739344

RESUMEN

The purpose of this study was to evaluate the in vivo dose-response relation of chromosome aberration formation and distribution in a context of localised and fractionated radiotherapy. Cytogenetic analysis was applied to eight patients, all treated for the same tumour localisation; the same localisation was used to prevent the variability usually observed between patients treated with radiotherapy and to allow the corresponding roles of the size of irradiation field and of the dose rate to be studied. The yield of dicentrics, centric rings and fragments was measured in blood samples taken before treatment, during the course of radiotherapy and up to 6 months after. After the first fraction of radiotherapy, we observed that the whole-body dose estimated from the yield of dicentrics and rings was higher (0.35+/-0.2 Gy) than the calculated equivalent whole-body dose (0.07+/-0.04 Gy). By contrast, the partial-body dose derived from the Qdr (quotient of dicentrics and rings) model was estimated to be 2.2+/-0.3 Gy, which agreed quite well with the dose delivered to the tumour (2.1+/-0.1 Gy). We also found a correlation between the yield of induced chromosome aberrations and the target field size (p = 0.014). U-value analysis showed that the distribution of dicentrics and rings was overdispersed, despite the fractionation of the exposure, and a positive correlation between the U-value and the dose rate was observed (p = 0.017). Overall, these results suggest that the proportion of undamaged lymphocytes could increase with the dose rate.


Asunto(s)
Aberraciones Cromosómicas , Neoplasias de Cabeza y Cuello/radioterapia , Linfocitos/efectos de la radiación , Anciano , Análisis Citogenético/métodos , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Femenino , Neoplasias de Cabeza y Cuello/genética , Humanos , Masculino , Persona de Mediana Edad
6.
J Radiat Res ; 48(5): 425-34, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17785937

RESUMEN

PURPOSE: To compare translocation rate using either M-FISH or FISH-3 in two patients treated for head and neck cancer, with a view to retrospective dosimetry. MATERIALS AND METHODS: Translocation analysis was performed on peripheral blood lymphocyte cultures from blood samples taken at different times during the radiotherapy (0 Gy, 12 Gy and 50 Gy) and a few months after the end of the treatment (follow-up). RESULTS: Estimated translocation yield varied according to the FISH technique used. At 50 Gy and follow-up points, the translocation yields were higher with FISH-3 than with M-FISH. This difference can be attributed to three events. First, an increase in complex aberrations was observed for 50 Gy and follow-up points compared with 0 Gy and 12 Gy points. Second, at the end of treatment for patient A, involvement of chromosomes 2, 4, 12 in translocations was less than expected according to the Lucas formula. Third, a clone bearing a translocation involving a FISH-3 painted chromosome was detected. CONCLUSIONS: More translocations were detected with M-FISH than with FISH-3, and so M-FISH is expected to improve the accuracy of chromosome aberration analyses in some situations.


Asunto(s)
Pintura Cromosómica/métodos , Neoplasias de Cabeza y Cuello/genética , Neoplasias de Cabeza y Cuello/radioterapia , Hibridación Fluorescente in Situ/métodos , Microscopía de Fluorescencia por Excitación Multifotónica/métodos , Translocación Genética/genética , Translocación Genética/efectos de la radiación , Anciano , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...