Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Rev Esp Cardiol (Engl Ed) ; 72(9): 732-739, 2019 Sep.
Artículo en Inglés, Español | MEDLINE | ID: mdl-30042008

RESUMEN

INTRODUCTION AND OBJECTIVES: Late functional tricuspid regurgitation after rheumatic left-sided valve surgery is an important predictor of poor prognosis. This study investigated the usefulness and accuracy of 3-dimensional transthoracic echocardiography tricuspid area compared with conventional 2-dimensional diameter (2DD) for assessing significant tricuspid annulus dilatation, providing cutoff values that could be used in clinical practice to improve patient selection for surgery. METHODS: We prospectively included 109 patients with rheumatic heart disease in the absence of previous valve replacement. Tricuspid regurgitation was divided into 3 groups: mild, moderate, and severe. Optimal 3-dimensional area (3DA) and 2DD cutoff points for identification of significant tricuspid annulus dilatation were obtained and compared with current guideline thresholds. Predictive factors for 3DA dilatation were also assessed. RESULTS: Optimal cutoff points for both absolute and adjusted to body surface area (BSA) tricuspid annulus dilatation were identified (3DA: 10.4 cm2, 6.5 cm2/m2; 2DD: 35 mm, 21 mm/m2); 3DA/BSA had the best diagnostic performance (AUC=0.83). Three-dimensional transthoracic echocardiography tricuspid area helped to reclassify surgical indication in 14% of patients with mild tricuspid regurgitation (95%CI, 1%-15%; P=.03) and 37% with moderate tricuspid regurgitation (95%CI, 22%-37%; P<.0001), whereas 3DA/BSA changed surgery criteria in cases of mild tricuspid regurgitation (17%; 95%CI, 3%-17%; P=.01) compared with 2DD/BSA. On multivariable analysis, right and left atrial volumes and basal right ventricle diameter were independently correlated with 3DA. CONCLUSIONS: The current 40 mm threshold underestimates tricuspid annulus dilatation. Although 21 mm/m2 seems to be a reasonable criterion, the combination with 3DA assessment improves patient selection for surgery.


Asunto(s)
Anuloplastia de la Válvula Cardíaca/métodos , Ecocardiografía Tridimensional/métodos , Selección de Paciente , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Anciano , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico
2.
Rev Esp Cardiol (Engl Ed) ; 71(2): 105-109, 2018 Feb.
Artículo en Inglés, Español | MEDLINE | ID: mdl-28528881

RESUMEN

INTRODUCTION AND OBJECTIVES: Multidetector computed tomography (MDCT) has been demonstrated as a feasible alternative to invasive coronary angiography (ICA). However, contradictory results have been reported regarding the effect of coronary artery calcium score (CS) on the diagnostic accuracy of MDCT. Our aim was to assess the agreement of MDCT and ICA and to evaluate the influence of CS on this agreement. METHODS: We enrolled 266 consecutive patients who underwent evaluation with 64-slice MDCT and ICA. Standard CS software tools were used to calculate the Agatston score. Stenosis was qualitatively classified as mild, moderate, or severe by 1 blinded observer and the results were compared with those of ICA, which was used as the gold standard. RESULTS: The mean age of the patients was 65.4 ± 11.2 years, and 188 patients (70.3%) were men. A total of 484 segments with coronary stenosis ≥ mild were qualitatively evaluated and quantified with MDCT. Noninvasive measurements were concordant with ICA in 402 stenoses (83.05%; Kappa, 0.684), with no significant differences between vessels and with no statistically significant influence of CS on this agreement (OR, 0.93; 95%CI, 0.76-1.09; P = .21). Multidetector computed tomography had high sensitivity, specificity, positive predictive value, and negative predictive value on a per-segment, per-vessel, and per-patient basis. CONCLUSIONS: Non-ICA using MDCT showed good agreement with ICA in the qualitative quantification coronary stenosis and CS had no significant impact on this agreement.


Asunto(s)
Calcinosis/complicaciones , Calcio/metabolismo , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada Multidetector/métodos , Anciano , Calcinosis/diagnóstico , Calcinosis/metabolismo , Estenosis Coronaria/etiología , Estenosis Coronaria/metabolismo , Vasos Coronarios/metabolismo , Femenino , Humanos , Masculino , Curva ROC , Reproducibilidad de los Resultados
3.
Orthop Surg ; 9(4): 331-341, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29178309

RESUMEN

One of its most serious complications associated with arthroplasty is the development of infections. Although its prevalence is only between 0.5% and 3%, in some cases it can lead to death. Therefore, an important challenge in joint surgery is the prevention of infections when an arthroplasty is performed. The use of antibiotic-loaded cements could be a suitable tool due to numerous advantages. The main advantage of the use of antibiotic loading into bone cement derives directly from antibiotic release in the effect site, allowing achievement of high concentrations at the site of action, and minimal or no systemic toxicity. This route of administration was first described by Buchholz and Engelbrecht. In the case of infection treatment, this is an established method and its good results have been confirmed. However, its role in infection prevention, and, therefore, the use of these systems in clinical practice, has proved controversial because of the uncertainty about the development of possible antibiotic resistance after prolonged exposure time, their effectiveness, the cost of the systems, toxicity and loosening of mechanical properties. This review discusses all these topics, focusing on effectiveness and safety, antibiotic decisions, cement type, mixing method, release kinetics and future perspectives. The final objective is to provide the orthopaedic surgeons the right information in their clinical practice based on current evidence.


Asunto(s)
Antibacterianos/administración & dosificación , Artroplastia de Reemplazo/métodos , Cementos para Huesos/química , Prótesis Articulares/efectos adversos , Infecciones Relacionadas con Prótesis/prevención & control , Antibacterianos/uso terapéutico , Humanos , Resultado del Tratamiento
4.
Sensors (Basel) ; 17(5)2017 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-28467366

RESUMEN

The use of information and communication technologies (ICTs) to improve the quality of life of people with chronic and degenerative diseases is a topic receiving much attention nowadays. We can observe that new technologies have driven numerous scientific projects in e-Health, encompassing Smart and Mobile Health, in order to address all the matters related to data processing and health. Our work focuses on helping to improve the quality of life of people with Parkinson's Disease (PD) and Essential Tremor (ET) by means of a low-cost platform that enables them to read books in an easy manner. Our system is composed of two robotic arms and a graphical interface developed for Android platforms. After several tests, our proposal has achieved a 96.5% accuracy for A4 80 gr non-glossy paper. Moreover, our system has outperformed the state-of-the-art platforms considering different types of paper and inclined surfaces. The feedback from ET and PD patients was collected at "La Princesa" University Hospital in Madrid and was used to study the user experience. Several features such as ease of use, speed, correct behavior or confidence were measured via patient feedback, and a high level of satisfaction was awarded to most of them. According to the patients, our system is a promising tool for facilitating the activity of reading.


Asunto(s)
Temblor Esencial , Enfermedad de Parkinson , Humanos , Calidad de Vida , Lectura
5.
Int J Cardiol ; 223: 713-716, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27573594

RESUMEN

OBJETIVES: The clinical and prognostic usefulness of tricuspid annular plane systolic excursion (TAPSE) is well established. However, the ability of TAPSE to assess right ventricular (RV) function in patients with previous tricuspid valve annulopasty is controversial. This study examined the TAPSE suitability in patients with previous tricuspid valve annuloplasty using right ventricular fractional area change (RVFAC) as reference method. METHODS: We retrospectively analyzed 53 patients who underwent tricuspid valve annuloplasty at our hospital between 2013 and 2016. TAPSE and RVFAC were obtained in preoperative and postoperative periods using standard methodology. RESULTS: Mean age was 68±12years and 34 patients (64.1%) were women. TAPSE decreased significantly after surgery in comparison with pre-surgical values (17±4.2 Vs 12.9±4.1mm, p<0.001). On the contrary, RVFAC did not change significantly after surgery (37±9.2 Vs 36.2.9, p=0.25). The correlation between RVFAC and TAPSE was better in the preoperative (r=0.63, p<0.0001) than in the postoperative period (r=0.38, P=0.005). Good intra- and interobserver agreement for TAPSE and RVFAC was obtained, with intraclass correlation coefficients of 0.97 and 0.92 for TAPSE; and 0.90 and 0.85 for RVFAC, respectively. CONCLUSIONS: These findings suggest that TAPSE is not suitable after tricuspid valve annuloplasty and it leads to an underestimation of RV systolic function. It seems to be appropriate to rely on echocardiographic parameters of global RV function such as RVFAC in this context.


Asunto(s)
Anuloplastia de la Válvula Cardíaca , Ecocardiografía/métodos , Ventrículos Cardíacos/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Función Ventricular Derecha/fisiología , Anciano , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Periodo Posoperatorio , Estudios Retrospectivos , Sístole , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico
8.
World J Cardiol ; 7(7): 431-3, 2015 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-26225205

RESUMEN

Left ventricular aneurysms are a frequent complication of acute extensive myocardial infarction and are most commonly located at the ventricular apex. A timely diagnosis is vital due to the serious complications that can occur, including heart failure, thromboembolism, or tachyarrhythmias. We report the case of a 78-year-old male with history of previous anterior myocardial infarction and currently under evaluation by chronic heart failure. Transthoracic echocardiogram revealed a huge thrombosed and calcified anteroapical left ventricular aneurysm. Coronary angiography demonstrated that the left anterior descending artery was chronically occluded, and revealed a big and spherical mass with calcified borders in the left hemithorax. Left ventriculogram confirmed that this spherical mass was a giant calcified left ventricular aneurysm, causing very severe left ventricular systolic dysfunction. The patient underwent cardioverter-defibrillator implantation for primary prevention.

14.
J Am Soc Echocardiogr ; 27(8): 838-45, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24909790

RESUMEN

BACKGROUND: The two-dimensional (2D) proximal isovelocity surface area (PISA) method has important technical limitations for mitral valve orifice area (MVA) assessment in mitral stenosis (MS), mainly the geometric assumptions of PISA shape and the requirement of an angle correction factor. Single-beat real-time three-dimensional (3D) color Doppler imaging allows the direct measurement of PISA without geometric assumptions or the requirement of an angle correction factor. The aim of this study was to validate this method in patients with rheumatic MS. METHODS: Sixty-three consecutive patients with rheumatic MS were included. MVA was assessed using the transthoracic 2D and 3D PISA methods. Planimetry of MVA (2D and 3D) and the pressure half-time method were used as reference methods. RESULTS: The 3D PISA method had better correlations with the reference methods (with 2D planimetry, r = 0.85, P < .001; with 3D planimetry, r = 0.89, P < .001; and with pressure half-time, r = 0.85, P < .001) than the conventional 2D PISA method (with 2D planimetry, r = 0.63, P < .001; with 3D planimetry, r = 0.66, P < .001; and with pressure half-time, r = 0.68, P < .001). In addition, a consistent significant underestimation of MVA using the conventional 2D PISA method was observed. A high percentage (30%) of patients with nonsevere MS by 3D planimetry were misclassified by the 2D PISA method as having severe MS (effective regurgitant orifice area < 1 cm(2)). In contrast, the 3D PISA method had 94% agreement with 3D planimetry. Good intra- and interobserver agreement for 3D PISA measurements were observed, with intraclass correlation coefficients of 0.95 and 0.90, respectively. CONCLUSIONS: MVA assessment using PISA by single-beat real-time 3D color Doppler echocardiography is feasible in the clinical setting and more accurate than the conventional 2D PISA method.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Ecocardiografía Doppler en Color/métodos , Ecocardiografía Tridimensional/métodos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Cardiopatía Reumática/diagnóstico por imagen , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estenosis de la Válvula Mitral/etiología , Estenosis de la Válvula Mitral/fisiopatología , Estudios Prospectivos , Reproducibilidad de los Resultados , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/fisiopatología , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...