Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Surg Innov ; 27(4): 320-327, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32524900

RESUMEN

Introduction. Connected systems transmitting vital parameters could well represent a tool to shorten postoperative hospital stay while providing continuous remote patient monitoring and potentially detect the onset of complications. Our aim was to analyze the functionality of a transcutaneous biosensing data collection patch in morbidly obese patients. Materials and Methods. An adhesive patch (The HealthPatch MD™) was applied to patients' chests postoperatively. The patch was connected to a tablet via a bluetooth network to collect the heart rate, respiratory rate, skin temperature, and posture recognition data. The tablet conveyed data to a secure health data central server by means of a WiFi or 3G/4G transmission. Data were stored in a digital health platform to which health care professionals could connect. The evaluation focused on the volume, quality, and security of data transmission. A pilot phase involved 10 patients. Thirty-three additional patients undergoing bariatric surgery were included in the experimental phase. Results. The mean length of stay was 2.28 days (range: 2-5 days). The mean time of patch application was 51 ± 25.2 hours per patient (range: 19-139 hours), totalizing 1,683 hours of recording for the 33 patients included. During this time, a total of 7.562.531 data measurement points were collected and transmitted to the e-health platform via the patch. Two total disconnections and two partial disconnections were observed. The acquisition of patient postural data was unreliable. Conclusions. Connected telemetry for remote postoperative monitoring is promising. However, it is still limited by data transmission problems.


Asunto(s)
Cirugía Bariátrica , Obesidad Mórbida , Recolección de Datos , Humanos , Monitoreo Fisiológico , Obesidad Mórbida/cirugía , Telemetría
2.
Hepatobiliary Surg Nutr ; 7(5): 345-352, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30498710

RESUMEN

BACKGROUND: The aim of this study was to analyze the clinical and economic impact of robotic distal pancreatectomy, laparoscopic distal pancreatectomy, and open distal pancreatectomy. METHODS: All consecutive patients who underwent distal pancreatic resection for benign and malignant diseases between January 2012 and December 2015 were prospectively included. Cost analysis was performed; all charges from patient admission to discharge were considered. RESULTS: There were 21 robotic (RDP), 25 laparoscopic (LDP), and 43 open (ODP) procedures. Operative time was longer in the RDP group (RDP =345 minutes, LDP =306 min, ODP =251 min, P=0.01). Blood loss was higher in the ODP group (RDP =192 mL, LDP =356 mL, ODP =573 mL, P=0.0002). Spleen preservation was more frequent in the RDP group (RDP =66.6%, LDP =61.9%, ODP =9.3%, P=0.001). The rate of patients with Clavien-Dindo > grade III was higher in the ODP group (RDP =0%, LDP =12%, ODP =23%, P=0.01), especially for non-surgical complications, which were more frequent in the ODP group (RDP =9.5%, LDP =24%, ODP =41.8%, P=0.02). Length of hospital stay was increased in the ODP group (ODP =19 days, LDP =13 days, RDP =11 days, P=0.007). The total cost of the procedure, including the surgical procedure and postoperative course was higher in the ODP group (ODP =30,929 Euros, LDP =22,150 Euros, RDP =21,219 Euros, P=0.02). CONCLUSIONS: Cost-effective results of RDP seem to be similar to LDP with some better short-term outcomes.

3.
Surg Laparosc Endosc Percutan Tech ; 26(5): e91-e94, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27636149

RESUMEN

Robotic pancreaticoduodenectomy represents actually an emerging procedure for robot-assisted surgery. Considering complexity, extensive dissection, and difficult restoration of the digestive continuity, it remains a challenge for surgeons. The embedded video (Supplemental Digital Content 1, http://links.lww.com/SLE/A146) reports our standardized technique for robotic pancreaticoduodenectomy. In conclusion, robotic pancreaticoduodenectomy is feasible and can be safely performed. Further evaluation with clinical trials is required to validate its real benefits.


Asunto(s)
Pancreaticoduodenectomía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Anastomosis Quirúrgica , Disección/métodos , Humanos , Laparoscopía/métodos , Neumoperitoneo Artificial/métodos , Cirugía Asistida por Computador/métodos , Técnicas de Sutura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...