Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Neurointerv Surg ; 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39122254

RESUMEN

BACKGROUND: Sealing of the aneurysm neck with a Woven EndoBridge (WEB) device is recommended for disrupting the blood flow inside the aneurysm. This study investigates the relationship between WEB neck apposition and aneurysm occlusion rates. METHODS: Aneurysms treated with a WEB from March 2017 to May 2022 at a single center were included. WEB neck apposition (poor/good) and WEB protrusion (yes/no) were evaluated on post-detachment high resolution cone beam CT images. Angiographic occlusion was assessed with the Bicêtre Occlusion Scale score (BOSS). Univariate and multivariable analysis tested the association between neck apposition and occlusion rates. RESULTS: The study included 159 aneurysms in 141 patients (mean age 55.8±11.2 years; 64.2% women). Good neck apposition and protrusion were noted in 123 (77.4%) and 30 (18.9%) cases, respectively. Inter-rater agreements were good for neck apposition (κ=0.75) and protrusion (κ=0.78). Complete and adequate occlusion was achieved in 104 (65%) and 130 (82%) cases, respectively (median follow-up 18 months). Good neck apposition was a strong independent predictor for both adequate (adjusted OR (aOR)=5.9, 95% CI 2.4 to 14.9; P<0.001) and complete occlusion (aOR=7.1, 95% CI 3.0 to 18.1; P<0.001). Protrusion was more frequent in the adequate occlusion group versus the aneurysm recurrence group without reaching statistical significance (P=0.06), but was associated with more thromboembolic complications (9/30 (30%) vs 12/129 (9%); P<0.01). WEB shape modification was significantly greater in poor apposition cases (P=0.03). CONCLUSIONS: Achieving good neck apposition of the WEB strongly predicts aneurysm occlusion during follow-up. WEB protrusion should be minimized due to the increase in thromboembolic risk with limited impact on aneurysm occlusion.

2.
J Neurointerv Surg ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39214688

RESUMEN

BACKGROUND: Although flow diverters (FDs) have benefited from several technical improvements, recently concerns have arisen regarding the braid stability after implantation. Thus, we investigated frequency, predictive factors, and clinical impact of the phenomenon of FD braid deformation (FDBD). METHODS: Consecutive intracranial aneurysms (IAs) treated with various FDs, between January 2018 and July 2023, were reviewed to identify FDBD (defined as the deformation of a FD without any external force applied to it). Patient, aneurysm, procedural, and FD characteristics were retrieved and analyzed using univariate and multivariable analyses. Morbidity is defined as a score of +1 in the modified Rankin Scale at 3 months. RESULTS: In total, 245 FD procedures (271 FDs implanted; 25 multiple IAs treated with 1 FD) in 228 patients; FDBD was observed in 36/245 cases (14.7%), mainly at follow-up angiography (32/36, 88.9%); fish-mouthing was the most frequent FDBD. Morbidity was related to fish-mouthing and braid collapse and was significantly higher in the FDBD group after retreatment (p=0.04). Drawn filled tubing with platinum (DFT) (adjusted odds ratio (aOR)=7.0, 95% CI 3.0 to 17.5; p<0.001) and FD diameter (aOR=2.2, 95% CI 1.3 to 4.1; p<0.01) were identified as independent predictors of FDBD. The metal alloy composing the FD (p=0.13) and coated surfaces were not significantly associated with FDBD (p=0.54 in multivariable analysis). CONCLUSIONS: FDBD is a frequent phenomenon observed in about 15% of cases, and it was responsible for higher morbidity. Only FD characteristics (DFT and FD diameter) were independent determinants of FDBD. Future research should focus on the impact of novel braid configurations and materials on braid stability.

3.
Neurosurgery ; 94(1): 183-192, 2024 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-37728333

RESUMEN

BACKGROUND AND OBJECTIVES: The Woven EndoBridge (WEB) device has been increasingly used to treat wide-neck aneurysms showing a safe and effective profile, but a relatively high number of thromboembolic events (TEEs) have been reported with such treatment. We aimed to evaluate the incidence and management of TEEs and possible predictive factors related to WEB embolization of ruptured and unruptured intracranial aneurysms. METHODS: A single-center database with consecutive aneurysms treated with a WEB device between July 2012 and May 2022 was reviewed for intraoperative and delayed TEEs. Univariate and multivariable analyses were used to determine factors associated with TEEs. RESULTS: A total of 266 independent aneurysms were treated with WEB devices in 245 patients (mean age 55.78 ± 11.64 years, 169 (63.5%) females, 80 (30%) ruptured). The overall rate of TEEs is 13% (35/266), including 8.7% intraoperative. Symptomatic TEEs with clinical sequelae at a 3-month follow-up are reported to be 2.6% (7/266) with no TEE-related mortality. Both the replacement of a WEB device during the procedure (adjusted odds ratio = 2.61, 95% CI 1.24-5.49; P = .01) and ruptured aneurysms (adjusted odds ratio = 2.74, 95% CI 1.31-5.7; P = .007) were independent predictors of TEEs. A case-by-case management of intraprocedural TEE is also presented; tirofiban was successfully used in most cases of this cohort. CONCLUSION: In this study, we demonstrated that ruptured aneurysms and WEB device replacement during the procedure were independent predictive factors for TEEs. As a result, making the correct choice of WEB is crucial for improving treatment outcomes. Moreover, with proper medical management of TEEs, minimal morbidity and no mortality could be achieved, which reinforces the safety of the technique.


Asunto(s)
Aneurisma Roto , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Tromboembolia , Femenino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Masculino , Incidencia , Estudios Retrospectivos , Procedimientos Endovasculares/métodos , Resultado del Tratamiento , Aneurisma Intracraneal/epidemiología , Aneurisma Intracraneal/terapia , Aneurisma Intracraneal/complicaciones , Aneurisma Roto/epidemiología , Aneurisma Roto/terapia , Aneurisma Roto/complicaciones , Tromboembolia/epidemiología , Tromboembolia/etiología , Embolización Terapéutica/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...