Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Eye (Lond) ; 28(10): 1254-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24993320

RESUMEN

PURPOSE: To present two cases of the rare entity of bilateral superior keratoconus and to review the literature regarding presentation and clinical findings. METHODS: Case report based on chart review. RESULTS: Two patients presented to our corneal service with clinical and topographical features of superior keratoconus. CONCLUSION: The unusual clinical and topographical findings of superior keratoconus are presented and treatment options are considered.


Asunto(s)
Córnea/patología , Queratocono/diagnóstico , Adolescente , Adulto , Colágeno/metabolismo , Lentes de Contacto , Córnea/metabolismo , Sustancia Propia/metabolismo , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Femenino , Humanos , Queratocono/fisiopatología , Queratocono/terapia , Fármacos Fotosensibilizantes/uso terapéutico , Ajuste de Prótesis , Errores de Refracción/diagnóstico , Retinoscopía , Riboflavina/uso terapéutico , Lámpara de Hendidura , Rayos Ultravioleta , Agudeza Visual/fisiología
2.
Diabetologia ; 56(6): 1413-6, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23519462

RESUMEN

AIMS/HYPOTHESIS: Targeting the secretion of gut peptides such as glucagon-like peptide 1 (GLP-1) and peptide YY (PYY) is a strategy under development for the treatment of diabetes and obesity, aiming to mimic the beneficial alterations in intestinal physiology that follow gastric bypass surgery. In vitro systems are now well established for studying the mouse enteroendocrine system, but whether these accurately model the human gut remains unclear. The aim of this study was to establish and characterise human primary intestinal cultures as a model for assessing GLP-1 and PYY secretion in vitro. METHODS: Fresh surgical biopsies of human colon were digested with collagenase to generate primary cultures from which GLP-1 and PYY secretion were assayed in response to test stimuli. GLP-1 and PYY co-localisation were assessed by flow cytometry and immunofluorescence microscopy. RESULTS: GLP-1 and PYY were found localised in the same cells and the same secretory vesicles in human colonic tissue samples. GLP-1 release was increased to 2.6-fold the control value by forskolin + isobutylmethylxanthine (10 µmol/l each), 2.8-fold by phorbol myristate acetate (1 µmol/l) and 1.4-fold by linoleic acid (100 µmol/l). PYY release was increased to 2.0-, 1.8- and 1.3-fold by the same stimuli, respectively. Agonists of G-protein-coupled receptor (GPR)40/120 and G-protein-coupled bile acid receptor 1 (GPBAR1) each increased GLP-1 release to 1.5-fold, but a GPR119 agonist did not significantly stimulate secretion. CONCLUSIONS/INTERPRETATION: Primary human colonic cultures provide an in vitro model for interrogating the human enteroendocrine system, and co-secrete GLP-1 and PYY. We found no evidence of PYY-specific cells not producing GLP-1. GLP-1 secretion was enhanced by small molecule agonists of GPR40/120 and GPBAR1.


Asunto(s)
Colon/metabolismo , Péptido 1 Similar al Glucagón/metabolismo , Péptido YY/metabolismo , Células Cultivadas , Colagenasas/metabolismo , Células Enteroendocrinas/metabolismo , Citometría de Flujo , Humanos , Microscopía Fluorescente , Receptores Acoplados a Proteínas G/metabolismo
3.
J Physiol ; 589(Pt 5): 1081-93, 2011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21224236

RESUMEN

Glucagon like peptide 1 (GLP-1) based therapies are now widely used for the treatment of type 2 diabetes. Developing our understanding of intestinal GLP-1 release may facilitate the development of new therapeutics aimed at targeting the GLP-1 producing L-cells. This study was undertaken to characterise the electrical activity of primary L-cells and the importance of voltage gated sodium and calcium channels for GLP-1 secretion. Primary murine L-cells were identified and purified using transgenic mice expressing a fluorescent protein driven by the proglucagon promoter. Fluorescent L-cells were identified within primary colonic cultures for patch clamp recordings. GLP-1 secretion was measured from primary colonic cultures. L-cells purified by flow cytometry were used to measure gene expression by microarray and quantitative RT-PCR. Electrical activity in L-cells was due to large voltage gated sodium currents, inhibition of which by tetrodotoxin reduced both basal and glutamine-stimulated GLP-1 secretion. Voltage gated calcium channels were predominantly of the L-type, Q-type and T-type, by expression analysis, consistent with the finding that GLP-1 release was blocked both by nifedipine and ω-conotoxin MVIIC. We observed large voltage-dependent potassium currents, but only a small chromanol sensitive current that might be attributable to KCNQ1. GLP-1 release from primary L-cells is linked to electrical activity and activation of L-type and Q-type calcium currents. The concept of an electrically excitable L-cell provides a basis for understanding how GLP-1 release may be modulated by nutrient, hormonal and pharmaceutical stimuli.


Asunto(s)
Estimulación Eléctrica , Células Enteroendocrinas/metabolismo , Péptido 1 Similar al Glucagón/metabolismo , Potenciales de Acción/fisiología , Animales , Calcio/metabolismo , Bloqueadores de los Canales de Calcio/farmacología , Canales de Calcio/genética , Canales de Calcio/metabolismo , Células Cultivadas , Electrofisiología , Células Enteroendocrinas/efectos de los fármacos , Ensayo de Inmunoadsorción Enzimática , Citometría de Flujo , Activación del Canal Iónico/efectos de los fármacos , Activación del Canal Iónico/fisiología , Ratones , Ratones Transgénicos , Nifedipino/farmacología , Análisis de Secuencia por Matrices de Oligonucleótidos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
4.
Case Rep Ophthalmol Med ; 2011: 724395, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22606472

RESUMEN

A six-year-old girl presented with gradual loss of vision in the left eye a year after sustaining a lightning strike while in her home. Examination revealed healed burns to her cheek, left arm, and right leg and a dense left cataract. There was no evidence of other ocular sequelae, and her right eye was normal. Cataract surgery and lens implantation were performed on the left eye with good results. Isolated, unilateral, paediatric cataract due to lightning is discussed.

5.
Diabetologia ; 52(2): 289-298, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19082577

RESUMEN

AIMS/HYPOTHESIS: Glucose-dependent insulinotropic polypeptide (GIP) is an incretin hormone with anti-apoptotic effects on the pancreatic beta cell. The aim of this study was to generate transgenic mice with fluorescently labelled GIP-secreting K cells and to use these to investigate pathways by which K cells detect nutrients. METHODS: Transgenic mice were generated in which the GIP promoter drives the expression of the yellow fluorescent protein Venus. Fluorescent cells were purified by flow cytometry and analysed by quantitative RT-PCR. GIP secretion was assayed in primary cultures of small intestine. RESULTS: Expression of Venus in transgenic mice was restricted to K cells, as assessed by immunofluorescence and measurements of the Gip mRNA and GIP protein contents of purified cells. K cells expressed high levels of mRNA for Kir6.2 (also known as Kcnj11), Sur1 (also known as Abcc8), Sglt1 (also known as Slc5a1), and of the G-protein-coupled lipid receptors Gpr40 (also known as Ffar1), Gpr119 and Gpr120. In primary cultures, GIP release was stimulated by glucose, glutamine and linoleic acid, and potentiated by forskolin plus 3-isobutyl-1-methylxanthine (IBMX), but was unaffected by the artificial sweetener sucralose. Secretion was half-maximal at 0.6 mmol/l glucose and partially mimicked by alpha-methylglucopyranoside, suggesting the involvement of SGLT1. Tolbutamide triggered secretion under basal conditions, whereas diazoxide suppressed responses in forskolin/IBMX. CONCLUSIONS/INTERPRETATION: These transgenic mice and primary culture techniques provide novel opportunities to interrogate the mechanisms of GIP secretion. Glucose-triggered GIP secretion was SGLT1-dependent and modulated by K(ATP) channel activity but not determined by sweet taste receptors. Synergistic stimulation by elevated cAMP and glucose suggests that targeting appropriate G-protein-coupled receptors may provide opportunities to modulate GIP release in vivo.


Asunto(s)
Glucosa/farmacología , Células Asesinas Naturales/metabolismo , Actinas/genética , Animales , Proteínas de Unión al Calcio/genética , Cromosomas Artificiales Bacterianos , AMP Cíclico/metabolismo , Citometría de Flujo , Polipéptido Inhibidor Gástrico/genética , Polipéptido Inhibidor Gástrico/metabolismo , Células Asesinas Naturales/citología , Células Asesinas Naturales/efectos de los fármacos , Lipoproteínas/genética , Ratones , Ratones Transgénicos , Regiones Promotoras Genéticas , Ratas , Receptores de la Hormona Gastrointestinal/fisiología , Acetato de Tetradecanoilforbol/farmacología
6.
Biomaterials ; 20(11): 1003-15, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10378800

RESUMEN

Collagenous xenografts made from kangaroo tail tendon cross-linked with glutaraldehyde have a potential application in the reconstruction of massive digital tendon deficits. However, a limitation to the clinical use of these xenografts has been the optimization of collagen cross-linking, and subsequent bio-incorporation and retention of mechanical properties following implantation. The purpose of this study was to evaluate the effect of nitrous acid on modulating the biologic and mechanical properties of tendon xenografts cross-linked with glutaraldehyde. Tendon xenografts were pretreated with 0.1 or 0.01 M nitrous acid solution, prior to cross-linking in 2% glutaraldehyde and sterilization by gamma irradiation. Xenografts were implanted intramuscularly in rabbits to examine biocompatability, and also used to repair ovine digital extensor tendon deficits to evaluate functional incorporation. Histologically, intramuscularly implanted nitrous acid pretreated xenografts in rabbits had a greater degree of diffuse cellular infiltration into interstitial splits in the graft than controls after 12 weeks. Xenografts implanted in an ovine extensor tendon deficit were evaluated after 26 and 52 weeks. Rate of failure of tenorrhaphies between host tendon and xenografts overall (15/21) was significantly greater (P < 0.05) than for autografts (1/21), suggesting that the holding power of sutures in xenografts was inferior to that obtained in autografts. Tensile failure stress of midsections of both nitrous acid pretreated and control xenografts was about 100 MPa prior to implantation (time zero). After 26 and 52 weeks, failure stress of both types of xenografts was significantly less than at time zero (P < 0.05). At 52 weeks, failure stress of nitrous acid pretreated xenografts (47.4 +/- 3.1 MPa) was significantly less than control xenografts (63.7 +/- 5.4 MPa); (P < 0.05). However, nitrous acid pretreated xenografts were similar to control xenografts in failure load (357 +/- 29 and 354 +/- 26 N, respectively), but they tended to have larger cross-sectional areas (7.6 +/- 0.5 versus 5.7 +/- 0.6 mm2, respectively) which were responsible for the lower calculated value for failure stress. Histologically, autografts maintained their normal tissue architecture and evoked a more limited cellular response in surrounding tissues than xenografts (P < 0.05). Both types of xenograft were surrounded by a thicker cuff of cellular response than autografts. However, compared to control xenografts, nitrous acid pretreated xenografts had more extensive fragmentation and splitting of collagen bundles, and more diffuse cellular and vascular infiltration into these interstitial splits, and these alterations were apparently contributing to the greater 'swelling' of these xenografts. It was concluded that pretreatment of tendon xenografts with nitrous acid modulated their biologic and material properties. Further studies are needed to elucidate the mechanism of these effects, and to determine if the protocol for tendon xenograft preparation could be optimized for improved clinical performance.


Asunto(s)
Tendones/trasplante , Animales , Materiales Biocompatibles , Colágeno/química , Reactivos de Enlaces Cruzados , Rayos gamma , Glutaral , Macropodidae , Masculino , Ensayo de Materiales , Óxido Nitroso , Conejos , Ovinos , Esterilización , Tendones/efectos de los fármacos , Tendones/efectos de la radiación , Factores de Tiempo , Trasplante Autólogo , Trasplante Heterólogo
7.
Am J Sports Med ; 25(4): 472-8, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9240980

RESUMEN

The initial biomechanical properties of semitendinosus and patellar tendon autografts and their fixation strengths were investigated. Twenty fresh cadaveric knees from donors under 42 years of age were used in the study. After removing all soft tissues other than the anterior cruciate ligament, we determined the ultimate tensile strength (2195 +/- 427 N) and stiffness (306 +/- 80 N/mm) of the anterior cruciate ligament in nine knees. In six knees, anterior cruciate ligaments were reconstructed using an autologous patellar tendon graft with proximal and distal interference fit screws; this resulted in an ultimate tensile strength of 416 +/- 66 N. Five knees were reconstructed with quadruple-stranded (double-looped) semitendinosus tendons fixed proximally by a titanium button and braided tape and distally by tibial post screw. This resulted in an ultimate tensile strength of 612 +/- 73 N, which was significantly higher than the strength in the patellar tendon group. Graft stiffness did not differ between the groups and was 47 +/- 19 N/mm (N = 11). This study demonstrates that the reconstructed knees had only 20% to 30% of the ultimate tensile strength of the normal anterior cruciate ligament. In summary, the semitendinosus reconstruction using a button for proximal fixation is, at the time of surgery, approximately 50% stronger than patellar tendon reconstructions with similar stiffness.


Asunto(s)
Ligamento Cruzado Anterior/cirugía , Ligamento Rotuliano/trasplante , Tendones/trasplante , Adulto , Ligamento Cruzado Anterior/fisiología , Fenómenos Biomecánicos , Tornillos Óseos , Cadáver , Elasticidad , Humanos , Dispositivos de Fijación Ortopédica , Ligamento Rotuliano/fisiología , Poliésteres , Suturas , Tendones/fisiología , Resistencia a la Tracción , Tibia/cirugía , Titanio , Trasplante Autólogo
8.
Biomaterials ; 16(10): 803-7, 1995 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-7492711

RESUMEN

Strength and function of autogenic and xenogenic reconstruction of digital extensor tendons was examined in an ovine model. In this study, tendon-graft junctions were formed by either suture augmented with a woven polyester tube (A), or augmented and shielded from surrounding tissues by chemically-treated bovine pericardium (S). By 12 wk, both A and S sheep had returned to full range of motion. Mechanical strength of both the autograft-host and xenograft-host repair sites was similar, with a pooled strength of 131 +/- 25 N (n = 15). Similarly, the mid-portion xenograft strengths were constant at approximately 366 +/- 97 N (n = 7). In contrast, mid-portion autograft strengths decreased from 380 +/- 110 N (N = 4) to 120 +/- 66 N (n = 4) if shielding was omitted. The loss in autograft strength was attributed to loss of function associated with adhesions. The use of the augmentation device coupled with an adhesion barrier gives higher initial reconstruction strength and improved function during the host repair period up to 12 wk.


Asunto(s)
Materiales Biocompatibles , Prótesis e Implantes , Tendones/cirugía , Tendones/trasplante , Trasplante Autólogo/patología , Trasplante Heterólogo/patología , Animales , Bovinos , Movimiento , Poliésteres , Ovinos , Estrés Mecánico , Tendones/fisiología , Resistencia a la Tracción , Trasplante Autólogo/fisiología , Trasplante Heterólogo/fisiología
9.
Clin Mater ; 9(3-4): 149-54, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-10149965

RESUMEN

Radiation sterilisation of xenograft prostheses has been shown to cause damage to the material. Such damage has been imputed to affect the mechanical and biological properties and may contribute to long-term failure. This study has examined the effect of 25 kGy (2.5 Mrad) of gamma radiation on the mechanical and physicochemical properties and the biological function of a xenograft tendon bioprosthesis derived from glutaraldehyde cross-linked kangaroo tail tendon. The ultimate tensile stress of nonirradiated glutaraldehyde cross-linked tendon was greater than that of fresh frozen tendon, but irradiated cross-linked tendon did not differ. Irradiation did not alter the response to prolonged collagenase exposure. There was a decrease in overall apparent cross-link density (as determined by thermal denaturation temperature). After 12 months implantation, there was a slightly more active cellular response around irradiated tendon and the very peripheral fibres were infiltrated, but the mechanical properties of the retrieved implants were the same for irradiated and nonirradiated material. Gamma irradiation would appear to be a satisfactory method of sterilisation for glutaraldehyde cross-linked tendon materials. However, as damage to the cross-linked structure was detected in this study, it may not be appropriate in other applications.


Asunto(s)
Bioprótesis , Colágeno/efectos de la radiación , Tendones/efectos de la radiación , Animales , Reactivos de Enlaces Cruzados/farmacología , Rayos gamma , Glutaral/farmacología , Calor , Macropodidae , Masculino , Ensayo de Materiales , Diseño de Prótesis , Desnaturalización Proteica , Ovinos , Esterilización/métodos , Cola (estructura animal) , Tendones/efectos de los fármacos , Resistencia a la Tracción
10.
Biomaterials ; 12(6): 577-83, 1991 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-1772956

RESUMEN

A model for testing the properties of gliding tendon grafts has been developed that allows anastomoses to be evaluated separately from the mid-portion of the graft. In addition, two different graft materials may be implanted in one sheep foreleg whilst maintaining control (not operated) tendons in both the operated leg and contralateral foreleg. The model has been used to evaluate the response of xenografts made from chemically treated kangaroo tail tendon (KTT) compared with autografts. At 3 month the mid-sections of the glutaraldehyde-fixed xenografts maintained between 57 and 82% of their initial ultimate tensile strength whereas lyophilized KTT dropped to 10% and autografts retained 91% of initial strength. Sterilization by gamma-radiation of wet xenografts did not affect the material and implant properties significantly. Longer term studies are necessary to determine the resorption behaviour of the xenografts. Anastomosis strengths were found to be about the same for all grafts, at about 25% of the strength of the original tendon. Alternatives need to be investigated to improve this strength.


Asunto(s)
Tendones/trasplante , Trasplante Heterólogo , Anastomosis Quirúrgica , Animales , Fenómenos Biomecánicos , Elasticidad , Fijadores , Técnicas In Vitro , Macropodidae , Ensayo de Materiales , Ovinos , Tendones/patología , Tendones/fisiología , Resistencia a la Tracción/fisiología
11.
Clin Orthop Relat Res ; (267): 278-93, 1991 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-1828401

RESUMEN

This study compared the Leeds-Keio prosthesis with grafting of autogeneic patellar tendon for the reconstruction of the ovine anterior cruciate ligament under controlled conditions. Reconstructed knees from six sheep of each group were evaluated at 12, 26, and 52 weeks postreconstruction with respect to clinical assessment, gross pathology, mechanical properties, and histology. Although no difference in clinical assessment (anteroposterior draw, range of motion, and function) was noted between the prosthesis reconstruction and the autograft reconstruction, the prosthesis provided a higher strength initially, which remained relatively constant over the one-year study. However, prosthesis wear was observed, with up to 50% of Dacron fibers ruptured in some cases. Histologic sections indicated that in the ovine model, the Leeds-Keio prosthesis should be considered an artificial device and not a scaffold or stent that supports aligned collagenous growth. The autograft had low strength at 12 weeks, which increased over the study period. Despite acceptable clinical performance and adequate mechanical properties up to one year postimplantation, neither reconstruction approached the clinical or mechanical performance of the normal anterior cruciate ligament in the ovine model.


Asunto(s)
Ligamento Cruzado Anterior/cirugía , Tereftalatos Polietilenos , Prótesis e Implantes , Tendones/trasplante , Animales , Fenómenos Biomecánicos , Traumatismos de la Rodilla/cirugía , Articulación de la Rodilla/patología , Articulación de la Rodilla/fisiopatología , Métodos , Rango del Movimiento Articular , Ovinos
12.
Biomaterials ; 11(2): 89-96, 1990 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-2317538

RESUMEN

The reported ultimate tensile stress of the anterior cruciate ligament varies greatly, ranging from 13 to 147 MPa. This study shows that the orientation and degree of flexion of the bone-ligament-bone complex significantly alter the apparent ultimate tensile properties (ultimate tensile stress ranging from 60 +/- 3 to 123 +/- 15 MPa, ultimate specific extension from 37 +/- 7 to 93 +/- 20%), whilst the method chosen for measuring extension also affects the calculated specific extension of the bone-ligament-bone complex. It is suggested that, for considerations of prosthesis design and evaluation, the mechanical properties of the bone-ligament-bone complex should be measured in anterior draw and extension measured using points as close as possible to the positions of the ligamentous attachment sites.


Asunto(s)
Articulación de la Rodilla/fisiología , Ligamentos Articulares/fisiología , Animales , Fenómenos Biomecánicos , Técnicas In Vitro , Prótesis de la Rodilla , Valores de Referencia , Ovinos , Estrés Mecánico , Resistencia a la Tracción
13.
Neuropsychologia ; 28(9): 1003-6, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2259422

RESUMEN

Independent groups of subjects (n = 12) attempted to identify individual digits 0-9 using active or passive touch with a vibrotactile display (Optacon II). Repeated measures were taken on the hand factor. Number recognition was superior with active touch and with the left hand.


Asunto(s)
Atención , Aprendizaje Discriminativo , Lateralidad Funcional , Tacto , Adulto , Femenino , Humanos , Masculino , Tiempo de Reacción , Privación Sensorial , Umbral Sensorial , Vibración
14.
Arch Surg ; 124(7): 866-9, 1989 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-2662941

RESUMEN

Between June 1984 and January 1986, 155 carotid endarterectomies were performed with routine shunting. Serial duplex scanning was performed during an 18-month period on 124 vessels. The results of this duplex scan review revealed the following data: A normal scan was obtained in 87/124 (70.1%). Recurrent stenosis was identified in 35/124 (28.1%), and an occluded vessel was identified in 2/124 (1.6%). Of the total recurrent stenosis group, recurrent stenosis was graded mild in 22/124 (17.7%), moderate in 7/124 (5.6%), and severe in 6/124 (4.8%). Of the 35 vessels with recurrent stenosis by duplex scanning, 22/35 (62.8%) were in female patients, and 13/35 (37.2%) were in male patients. Of the vessels with severe recurrent stenosis, 5/6 (83%) were in female patients. Recurrent stenosis following carotid endarterectomy is more common than appreciated clinically, and female patients in particular may be more prone to recurrent stenosis.


Asunto(s)
Trombosis de las Arterias Carótidas/etiología , Endarterectomía/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Trombosis de las Arterias Carótidas/diagnóstico , Trastornos Cerebrovasculares/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...