Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Heart Rhythm ; 9(9): 1426-33.e3, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22554859

RESUMEN

BACKGROUND: Spinal cord stimulation (SCS) has been shown to modulate atrial electrophysiology and confer protection against ischemia and ventricular arrhythmias in animal models. OBJECTIVE: To determine whether SCS reduces the susceptibility to atrial fibrillation (AF) induced by tachypacing (TP). METHODS: In 21 canines, upper thoracic SCS systems and custom cardiac pacing systems were implanted. Right atrial and left atrial effective refractory periods were measured at baseline and after 15 minutes of SCS. Following recovery in a subset of canines, pacemakers were turned on to induce AF by alternately delivering TP and searching for AF. Canines were randomized to no SCS therapy (CTL) or intermittent SCS therapy on the initiation of TP (EARLY) or after 8 weeks of TP (LATE). AF burden (percent AF relative to total sense time) and AF inducibility (percentage of TP periods resulting in AF) were monitored weekly. After 15 weeks, echocardiography and histology were performed. RESULTS: Effective refractory periods increased by 21 ± 14 ms (P = .001) in the left atrium and 29 ± 12 ms (P = .002) in the right atrium after acute SCS. AF burden was reduced for 11 weeks in EARLY compared with CTL (P <.05) animals. AF inducibility remained lower by week 15 in EARLY compared with CTL animals (32% ± 10% vs 91% ± 6%; P <.05). AF burden and inducibility were not significantly different between LATE and CTL animals. There were no structural differences among any groups. CONCLUSIONS: SCS prolonged atrial effective refractory periods and reduced AF burden and inducibility in a canine AF model induced by TP. These data suggest that SCS may represent a treatment option for AF.


Asunto(s)
Fibrilación Atrial/prevención & control , Estimulación Cardíaca Artificial/efectos adversos , Estimulación de la Médula Espinal/métodos , Análisis de Varianza , Animales , Fibrilación Atrial/etiología , Fibrilación Atrial/patología , Modelos Animales de Enfermedad , Perros , Electrocardiografía , Atrios Cardíacos/inervación , Medición de Riesgo , Médula Espinal/fisiología , Factores de Tiempo
2.
Europace ; 11(5): 618-24, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19363053

RESUMEN

AIMS: To evaluate a novel atrial lead designed to reduce far-field sensing. METHODS AND RESULTS: Sixty-three patients with standard pacing indications were randomized to receive an OptiSense 1699T (St Jude Medical, USA) or conventional pacing lead in the right atrium. Post-implant follow-up was conducted for all patients at 90 days and for a subset at 360 days. Standard electrical parameters were measured. Thresholds of sensing were determined for far-field ventricular signals. The number of inappropriate mode switches was determined from the stored intracardiac electrogram (IEGM). At 90 days, an IEGM Holter recorded 24 h of IEGM. With atrial sensitivity programmed at 0.3 mV, no far-field sensing occurred in the OptiSense group, but it did occur in 20% and 30% of the control group at 90 and 360 days, respectively. Inappropriate mode switching was observed in 4% of the OptiSense group in contrast to 23% of the control group. The IEGM Holter found no far-field sensing in the OptiSense group, but did find 83 023 far-field events from 22% of control patients. The standard electrical parameters of the OptiSense leads were acceptable. CONCLUSION: The OptiSense lead reduced ventricular far-field sensing in the atrium while maintaining satisfactory pacing and sensing performance, resulting in less inappropriate mode switch.


Asunto(s)
Fibrilación Atrial/terapia , Electrocardiografía , Atrios Cardíacos/fisiopatología , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/fisiopatología , Electrocardiografía Ambulatoria , Diseño de Equipo , Femenino , Migración de Cuerpo Extraño , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...