Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Am Soc Echocardiogr ; 33(11): 1324-1333, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32868157

RESUMEN

BACKGROUND: Aortic stenosis (AS) severity assessment is based on several indices. Aortic valve area (AVA) is subject to inaccuracies inherent to the measurement method, while velocities and gradients depend on hemodynamic status. There is controversy as to whether blood pressure directly affects common indices of AS severity. OBJECTIVES: The study objective was to assess the effect of systolic blood pressure (SBP) variation on AS indices, in a clinical setting. METHODS: A prospective, single-center study included 100 patients with at least moderately severe AS with preserved left ventricle ejection fraction. Patients underwent ultrasound examination during which AS severity indices were collected, with three hemodynamic conditions: (1) low SBP: <120 mm Hg; (2) intermediate SBP: between 120 and 150 mm Hg; (3) high SBP: ≥150 mm Hg. For each patient, SBP profiles were obtained by injection of isosorbide dinitrate or phenylephrine. RESULTS: At baseline state, 59% presented a mean gradient (Gmean) ≥ 40 mm Hg, 44% a peak aortic jet velocity (Vpeak) ≥4 m/sec, 66% a dimensionless index (DI) ≤0.25, and 87% an indexed AVA (AVAi) ≤ 0.6 cm2/m2. Compared with intermediate and low SBP, high SBP induced a significant decrease in Gmean (39 ± 12 vs 43 ± 12 and 47 ± 12 mm Hg, respectively; P < .05) and in Vpeak (3.8 ± 0.6 vs 4.0 ± 0.6 and 4.2 ± 0.6 mm Hg; P < .05). Compared with the baseline measures, in 16% of patients with an initial Gmean< 40 mm Hg, gradient rose above 40 mm Hg after optimization of the afterload (low SBP; P < .05). Conversely, DI and AVAi did not vary with changes in hemodynamic conditions. Flow rate, not stroke volume was found to impact Gmean and Vpeak but not AVA and DI (P < .05). CONCLUSIONS: Hemodynamic conditions may affect the AS ultrasound assessment. High SBP, or afterload, leads to an underestimation of AS severity when based on gradients and velocities. Systolic blood pressure monitoring and control are crucial during AS ultrasound assessment.


Asunto(s)
Estenosis de la Válvula Aórtica , Presión Arterial , Válvula Aórtica , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Hemodinámica , Humanos , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Volumen Sistólico , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...