Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
PLoS One ; 16(9): e0257737, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34591884

RESUMEN

BACKGROUND: An association was reported between the left ventricular longitudinal strain (LV-LS) and preload. LV-LS reflects the left cardiac function curve as it is the ratio of shortening over diastolic dimension. The aim of this study was to determine the sensitivity and specificity of LV-LS variations after a passive leg raising (PLR) maneuver to predict fluid responsiveness in intensive care unit (ICU) patients with acute circulatory failure (ACF). METHODS: Patients with ACF were prospectively included. Preload-dependency was defined as a velocity time integral (VTI) variation greater than 10% between baseline (T0) and PLR (T1), distinguishing the preload-dependent (PLD+) group and the preload-independent (PLD-) group. A 7-cycles, 4-chamber echocardiography loop was registered at T0 and T1, and strain analysis was performed off-line by a blind clinician. A general linear model for repeated measures was used to compare the LV-LS variation (T0 to T1) between the two groups. RESULTS: From June 2018 to August 2019, 60 patients (PLD+ = 33, PLD- = 27) were consecutively enrolled. The VTI variations after PLR were +21% (±8) in the PLD+ group and -1% (±7) in the PLD- group (p<0.01). Mean baseline LV-LS was -11.3% (±4.2) in the PLD+ group and -13.0% (±4.2) in the PLD- group (p = 0.12). LV-LS increased in the whole population after PLR +16.0% (±4.0) (p = 0.04). The LV-LS variations after PLR were +19.0% (±31) (p = 0.05) in the PLD+ group and +11.0% (±38) (p = 0.25) in the PLD- group, with no significant difference between the two groups (p = 0.08). The area under the curve for the LV-LS variations between T0 and T1 was 0.63 [0.48-0.77]. CONCLUSION: Our study confirms that LV-LS is load-dependent; however, the variations in LV-LS after PLR is not a discriminating criterion to predict fluid responsiveness of ICU patients with ACF in this cohort.


Asunto(s)
Ecocardiografía Doppler/métodos , Pierna/fisiología , Choque/diagnóstico por imagen , Choque/tratamiento farmacológico , Vasoconstrictores/uso terapéutico , Adulto , Anciano , Femenino , Fluidoterapia , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Choque/fisiopatología , Volumen Sistólico , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA