Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37138103

RESUMEN

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Sistema de Registros , Diseño de Prótesis
4.
Int J Cardiol ; 383: 1-7, 2023 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-37085121

RESUMEN

BACKGROUND: The resorbable magnesium scaffold (RMS) is a second-generation bioresorbable scaffold (BRS) that has shown conflicting results in previous studies. These findings suggest that patient selection and implantation technique may have an impact on clinical outcomes. This study aimed to investigate the safety and long-term effectiveness of RMS in a narrowly selected population. METHODS: SHERPA-MAGIC is an investigator-driven, multicenter, prospective, single-arm study that enrolled patients undergoing BRS coronary implantation in 18 Italian centers. The present analysis considered the first 543 enrolled patients treated with RMS, with a minimum follow-up of 1 year. The study protocol included strict criteria for patient selection and standardization of RMS implantation. The primary outcome was the occurrence of the vessel-oriented composite endpoints (VOCE), including cardiac death, target vessel myocardial infarction, and ischemia-driven target vessel revascularization. RESULTS: Overall, 635 vessels were treated. The 1-year cumulative occurrence of VOCE was 22 (3.5%, 95% CI 2.2%-5.2%), which was significantly lower than the prespecified estimation (from 5.5% to 8.5%). At the median follow-up of 3.5 [2.6-4.3] years, there were 3 (0.5%) cardiac deaths, 12 (1.9%) target vessel myocardial infarctions, and 33 (5.2%) ischemia-driven target vessel revascularizations. A total of 37 (5.8%, 95%CI 4.1%-7.9%) VOCEs were detected. Scaffold thrombosis occurred in 4 (0.6%, 95%CI 0.1%-1.6%) cases. Patient-level analysis confirmed the findings of the vessel-level analysis. CONCLUSIONS: These results confirm the safety and performance of RMS technology. If confirmed in randomized controlled trials, they may rekindle interest in the use of scaffolds in daily practice.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Sirolimus , Magnesio , Estudios Prospectivos , Resultado del Tratamiento , Implantes Absorbibles , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio/etiología , Diseño de Prótesis
5.
Catheter Cardiovasc Interv ; 101(6): 1144-1153, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36924020

RESUMEN

AIMS: To compare outcomes of patients who underwent left atrial appendage occlusion (LAAO) for nonvalvular atrial fibrillation (NVAF) and contraindication to anticoagulants due to history of either gastrointestinal (GI) or intracranial (IC) bleeding. METHODS: Patients with NVAF that underwent LAAO for GI or IC bleeding from seven centers were included in this observational study. Baseline characteristics, procedural features, and follow-up data were collected, and compared between the two groups. The primary outcomes were incidence of ischemic and hemorrhagic events at 12-month. RESULTS: Six hundred twenty-eight patients were included, 57% with previous GI-bleeding, and 43% with previous IC-bleeding. Median CHA 2 DS 2-VASc score was 4 (interquartile range [IQRs]: 3-5) for both GI-bleeding and IC-bleeding patients, while GI-bleeding patients had a higher HAS-BLED score (4 [IQRs: 3-4] vs. 3 [IQRs]: 2-3]; p = 0.001). At 12-month follow-up, relative risk reduction for stroke was similar between the two groups. The GI-bleeding group had more hemorrhagic events compared to IC-bleeding group (any bleeding 8.4% vs. 3.2%; p = 0.012; major bleeding BARC 3-5: 4.3% vs. 1.8; p = 0.010). At multivariate analysis history of GI bleeding was an independent predictor of hemorrhagic events (adjusted HR: 2.39, 95% confidence interval: 1.02-5.63; p = 0.047). CONCLUSIONS: Outcomes after LAAO may be affected by the different indications for the procedure. In our study, GI-bleeding and IC-bleeding as indication to LAAO differ in their baseline characteristics. LAAO confirms its efficacy in ischemic risk reduction in both groups, while GI bleeding seems to be an independent predictor of bleeding recurrence at 12 months behind the antithrombotic regimen.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/prevención & control , Hemorragias Intracraneales/etiología , Sistema de Registros , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Lógica
6.
Minerva Cardiol Angiol ; 71(1): 12-19, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36305773

RESUMEN

BACKGROUND: The COVID-19 pandemic severely impacted global health. The aim of this study was to compare predictors of symptoms-to-emergency-call timing delay in acute coronary syndrome (ACS) and their impact on mortality before and during the COVID-19 outbreak. METHODS: We collected sociodemographic, clinical data, procedural features, preadmission and intra-hospital outcomes of consecutive patients admitted for ACS in seventeen Italian centers from March to April 2018, 2019, and 2020. RESULTS: In 2020, a 32.92% reduction in ACS admissions was observed compared to 2018 and 2019. Unstable angina, typical and atypical symptoms, and intermittent angina were identified as significant predictors of symptoms-to-emergency-call timing delay before and during the COVID-19 pandemic (P<0.005 for all the items). Differently from 2018-2019, during the pandemic, hypertension and dyspnea (P=0.002 versus P=0.490 and P=0.001 vs. P=0.761 for 2018-2019 and 2020, respectively) did not result as predictors of delay in symptoms-to-emergency-call timing. Among these predictors, only the atypical symptoms (HR 3.36; 95% CI: 1.172-9.667, P=0.024) in 2020 and the dyspnea (HR 2.64; 95% CI: 1.345-5.190, P=0.005) in 2018-2019 resulted significantly associated with higher mortality. Finally, the family attendance at the onset of the symptoms resulted in a reduction in symptoms-to-emergency-call timing (in 2020 P<0.001; CI: -1710.73; -493.19) and in a trend of reduced mortality (HR 0.31; 95% CI: 0.089-1.079, P=0.066) in 2020. CONCLUSIONS: During the COVID-19 outbreak, atypical symptoms and family attendance at ACS onset were identified, respectively, as adverse and favorable predictors of symptoms-to-emergency-call timing delay and mortality.


Asunto(s)
Síndrome Coronario Agudo , COVID-19 , Humanos , COVID-19/epidemiología , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/epidemiología , Pandemias , Angina Inestable/epidemiología , Disnea/epidemiología
7.
Minerva Cardiol Angiol ; 71(5): 515-524, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33944536

RESUMEN

INTRODUCTION: The concept of bioresorbable scaffolds (BRS) was born with the aim to reduce the rate of late and very late cardiac events related to drug-eluting stents. However, first-generation BRS failed to prove their short-term safety and efficacy. Based on data derived from early investigations, new-generation BRS have been developed and tested in preliminary studies. The present review's focus was to summarize the mechanical characteristics of these new scaffolds and the clinical evidence of their safety and efficacy. EVIDENCE ACQUISITION: This systematic review was performed following Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA). PUBMED, Google Scholar, and Biomed central databases were analyzed. Only papers published in English and in peer-reviewed journals were selected to summarize current evidence about new generation BRS, with CE mark approval. Overall, 23 studies were included. EVIDENCE SYNTHESIS: Data obtained from selected studies assessing the safety and efficacy of new generation BRS are encouraging. This is thanks to the progressive development of scaffolds with a different backbone structure and struts thickness that guarantee higher radial strength, flexibility, and resistance to fracture. These characteristics led to low rates of major adverse cardiac events and device-oriented composite endpoint at follow-up. CONCLUSIONS: New-generation BRS have a good safety profile in stable patients with simple lesions, supported by a meticulous implantation technique. The first studies were performed on a small population with short-term follow-up, therefore new randomized clinical trials and registries are needed to expand the preliminary findings.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Humanos , Enfermedad de la Arteria Coronaria/cirugía , Implantes Absorbibles , Resultado del Tratamiento , Stents Liberadores de Fármacos/efectos adversos
8.
Interv Cardiol ; 18: e30, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38213745

RESUMEN

Since the first robotic-assisted percutaneous coronary intervention procedure (R-PCI) was performed in 2004, there has been a steady evolution in robotic technology, combined with a growth in the number of robotic installations worldwide and operator experience. This review summarises the latest developments in R-PCI with a focus on developments in robotic technology, procedural complexity, tele-stenting and training methods, which have all contributed to the global expansion in R-PCI.

9.
Life (Basel) ; 12(10)2022 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-36295047

RESUMEN

BACKGROUND: Little evidence to date has described the feasibility and diagnostic accuracy of coronary computed tomography angiography (CCTA) with noninvasive fractional flow reserve (CT-FFR) in coronary vessels with resorbable magnesium scaffold (RMS). METHODS: The SHERPA-MAGIC is a prospective study enrolling patients receiving RMS. The present analysis considered patients undergoing CCTA 18 months after the index procedure. CCTA images were employed to investigate reabsorption status, luminal measurements, and noninvasive FFR. Three-year follow-up was available for all patients. RESULTS: Overall, 26 patients with a total of 29 coronary arteries treated with 35 RMS were considered. The most frequently involved vessel was left anterior descendent (LAD). Median stent length was 25 (20-25) mm, with a median diameter of 3 (3-3.5) mm. At 18-month CCTA, all scaffolded segments were patent. Complete RMS reabsorption was observed in 27 (93%, 95% CI 77-99%) cases. Median minimal lumen diameter (MLD) and area (MLA) of the scaffolded segments were 2.5 [2.1-2.8] mm and 6.4 [4.4-8.4] mm2, respectively. Median CT-FFR was 0.88 [0.81-0.91]. Only one (3.5%) vessel showed a flow-limiting CT-FFR value ≤0.80. During the 3-year follow-up, only one (4%) adverse event was observed. Conclusions: In patients undergoing RMS implantation, CCTA including noninvasive CT-FFR evaluation is feasible and allows investigation of long-term RMS performance.

10.
Front Cardiovasc Med ; 9: 902564, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36187005

RESUMEN

Background: Coronary access after transcatheter aortic valve implantation (TAVI) with supra-annular self-expandable valves may be challenging or un-feasible. There is little data concerning coronary access following transcatheter aortic valve-in-valve implantation (ViV-TAVI) for degenerated surgical bioprosthesis. Aims: To evaluate the feasibility and challenge of coronary access after ViV-TAVI with the supra-annular self-expandable ACURATE neo valve. Materials and methods: Sixteen patients underwent ViV-TAVI with the ACURATE neo valve. Post-procedural computed tomography (CT) was used to create 3D-printed life-sized patient-specific models for bench-testing of coronary cannulation. Primary endpoint was feasibility of diagnostic angiography and PCI. Secondary endpoints included incidence of challenging cannulation for both diagnostic catheters (DC) and guiding catheters (GC). The association between challenging cannulations with aortic and transcatheter/surgical valve geometry was evaluated using pre and post-procedural CT scans. Results: Diagnostic angiography and PCI were feasible for 97 and 95% of models respectively. All non-feasible procedures occurred in ostia that underwent prophylactic "chimney" stenting. DC cannulation was challenging in 17% of models and was associated with a narrower SoV width (30 vs. 35 mm, p < 0.01), STJ width (28 vs. 32 mm, p < 0.05) and shorter STJ height (15 vs. 17 mm, p < 0.05). GC cannulation was challenging in 23% of models and was associated with narrower STJ width (28 vs. 32 mm, p < 0.05), smaller transcatheter-to-coronary distance (5 vs. 9.2 mm, p < 0.05) and a worse coronary-commissural overlap angle (14.3° vs. 25.6 o , p < 0.01). Advanced techniques to achieve GC cannulation were required in 22/64 (34%) of cases. Conclusion: In this exploratory bench analysis, diagnostic angiography and PCI was feasible in almost all cases following ViV-TAVI with the ACURATE neo valve. Prophylactic coronary stenting, higher implantation, narrower aortic sinus dimensions and commissural misalignment were associated with an increased challenge of coronary cannulation.

13.
J Clin Med ; 11(10)2022 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-35629052

RESUMEN

BACKGROUND: The COVID-19 pandemic increased the complexity of the clinical management and pharmacological treatment of patients presenting with an Acute Coronary Syndrome (ACS). AIM: to explore the incidence and prognostic impact of in-hospital bleeding in patients presenting with ACS before and during the COVID-19 pandemic. METHODS: We evaluated in-hospital Thrombolysis In Myocardial Infarction (TIMI) major and minor bleeding among 2851 patients with ACS from 17 Italian centers during the first wave of the COVID-19 pandemic (i.e., March-April 2020) and in the same period in the previous two years. RESULTS: The incidence of in-hospital TIMI major and minor bleeding was similar before and during the COVID-19 pandemic. TIMI major or minor bleeding was associated with a significant threefold increase in all-cause mortality, with a similar prognostic impact before and during the COVID-19 pandemic. CONCLUSIONS: the incidence and clinical impact of in-hospital bleeding in ACS patients was similar before and during the COVID-19 pandemic. We confirmed a significant and sizable negative prognostic impact of in-hospital bleeding in ACS patients.

14.
Panminerva Med ; 64(4): 427-437, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35638242

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established management strategy for severe aortic valve stenosis. Percutaneous axillary approach for TAVI holds the promise of improving safety without jeopardizing effectiveness in comparison to surgical access. We aimed at appraising the comparative effectiveness of percutaneous vs. surgical axillary approaches for TAVI. METHODS: We performed an international retrospective observational study using de-identified details on baseline, procedural, and 1-month follow-up features. Valve Academic Research Consortium (VARC)-3 criteria were applied throughout. Outcomes of interest were clinical events up to 1 month of follow-up, compared with unadjusted and propensity score-adjusted analyses. RESULTS: A total of 432 patients were included, 189 (43.8%) receiving surgical access, and 243 (56.2%) undergoing percutaneous access. Primary hemostasis failure was more common in the percutaneous group (13.2% vs. 4.2%, P<0.001), leading to more common use of covered stent implantation (13.2% vs. 3.7%, P<0.001). Irrespectively, percutaneous access was associated with shorter hospital stay (-2.6 days [95% confidence interval: -5.0; -0.1], P=0.038), a lower risk of major adverse events (a composite of death, myocardial infarction, stroke, type 3 bleeding, and major access-site related complication; odds ratio=0.44 [0.21; 0.95], P=0.036), major access-site non-vascular complications (odds ratio=0.21 [0.06; 0.77], P=0.018), and brachial plexus impairment (odds ratio=0.16 [0.03; 0.76], P=0.021), and shorter hospital stay (-2.6 days [-5.0; -0.1], P=0.038). CONCLUSIONS: Percutaneous axillary access provides similar or better results than surgical access in patients undergoing TAVI with absolute or relative contraindications to femoral access.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Sistema de Registros , Estudios Retrospectivos , Válvula Aórtica/cirugía , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA