Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 57(5)2021 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-34063687

RESUMEN

Background and Objective: Breast implant surgery for cosmetic purposes is the most popular plastic surgery and it has been performed for over 100 years. Rupture of silicone gel-filled breast implants usually is asymptomatic and is one of the more dangerous complications due to free silicone migration. The aim of our study was to evaluate the diagnostic value of ultrasound (US) in the evaluation of the integrity of silicone breast implants and identify the main sign of intact and ruptured breast implants. Patients and Methods: In this retrospective study, the medical documentation of women who underwent breast implant surgery and US checkups at Tautrimas Astrauskas Clinic in Kaunas, Lithuania, during 2015-2020 was analyzed. The patients were divided into two groups: patients with intact and ruptured breast implants. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) as well as the signs of implant integrity of US examination were evaluated. Results: In this study, 76 women with bilateral breast implants (n = 152) were reviewed. On a US examination, ruptured implants were found in 41.1% (n = 61) of the cases; of them, 78.7% (n = 48) of the cases had ≥2 US signs of a ruptured implant, and in all these cases, implant rupture was confirmed at surgery. Overall, one US sign of a ruptured implant was found in 21.3% (n = 13) of the cases. Of them, inhomogeneous content in all cases (n = 3) was found in the intact implant group, and an abnormal implant shell was documented more often in the ruptured implant group, not intact one (n = 9, 90% vs. n = 1, 10%). US had a diagnostic accuracy of 94.7%, sensitivity of 98.3%, specificity of 89.2%, PPV of 93.4%, and NPV of 97.1% in the evaluation of implant integrity. Conclusions: Our results show that US is a very reliable alternative in evaluating breast implant integrity and could be the investigation of choice for implant rupture, while MRI could be advocated only in inconclusive cases. Uneven implant shell was found to be the most important US sign of breast implant rupture. Based on the findings, we recommend performing US examination after breast augmentation surgery with silicone gel-filled implants annually.


Asunto(s)
Implantes de Mama , Implantes de Mama/efectos adversos , Femenino , Humanos , Lituania , Imagen por Resonancia Magnética , Falla de Prótesis , Estudios Retrospectivos , Geles de Silicona/efectos adversos
2.
Medicina (Kaunas) ; 56(3)2020 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-32183080

RESUMEN

Background and objectives: With improved diagnostic means of early breast cancer, the percentage of cases with metastasis in axillary lymph nodes has decreased from 50%-75% to 15%-30%. Lymphadenectomy and sentinel lymph node biopsy are not treatment procedures, as they aim at axillary nodal staging in breast cancer. Being surgical interventions, they can lead to various complications. Therefore, recently much attention has been paid to the identification of non-invasive methods for axillary nodal staging. In many countries, ultrasound is a first-line method to evaluate axillary lymph node status. The aim of this study was to evaluate the prognostic value of ultrasound in detecting intact axillary lymph nodes and to assess the accuracy of ultrasound in detecting a heavy nodal disease burden. The additional objective was to evaluate patients' and tumor characteristics leading to false-negative results. Materials and Methods: A total of 227 women with newly diagnosed pT1 breast cancer were included to this prospective study conducted at the Breast Surgery Unit, Clinic of Surgery, Hospital of Lithuanian University of Health Sciences Kauno Klinikos, between May 1, 2016, and May 31, 2018. All patients underwent preoperative axillary ultrasound examination. Ultrasound data were compared with the results of histological examination. The accuracy and true-negative rate of ultrasound were calculated. The reasons of false-negative results were analyzed. Results: Of the 189 patients who had normally appearing axillary lymph nodes on preoperative ultrasound (PAUS-negative), 173 (91.5%) patients were also confirmed to have intact axillary lymph nodes (node-negative) by histological examination after surgery. The accuracy and the negative predictive value of ultrasound examination were 84.1% and 91.5%, respectively. In ≥3 node-positive cases, the accuracy and the negative predictive value increased to 88.7% and 98.3%, respectively. In total, false-negative results were found in 8.5% of the cases (n = 16); in the PAUS-negative group, false-negative results were recorded only in 1.6% of the cases (n = 3). The results of PAUS and pathological examination differed significantly between patients without and with lymphovascular invasion (LV0 vs. LV1, p < 0.001) as well as those showing no human epidermal growth factor receptor 2 (HER2) expression and patients with weakly or strongly expressed HER2 (HER2(0) vs. HER2(1), p = 0.024). Paired comparisons revealed that the true-negative rate was significantly different between the LV0 and LV1 groups (91% vs. 66.7%, p < 0.05), and the false-negative rate was statistically significant different between the HER2(0) and HER2(1) groups (10.5% vs. 1.2%, p < 0.05). Evaluation of other characteristics showed both the groups to be homogenous. Conclusions: Negative axillary ultrasound excluded axillary metastatic disease in 91.5% of the patients. PAUS had an accuracy of 88.7% in detecting a heavy nodal disease burden. With the absence of lymphovascular invasion (LV0), we can rely on PAUS examination that axillary lymph nodes are intact (PAUS-negative), and this patients' group could avoid sentinel lymph node biopsy. Patients without HER2 expression are at a greater likelihood of false-negative results; therefore, the findings of ultrasound that axillary lymph nodes are intact (PAUS-negative results) should be interpreted with caution.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Biopsia del Ganglio Linfático Centinela/métodos , Factores de Tiempo , Ultrasonografía/métodos , Adulto , Anciano , Axila/diagnóstico por imagen , Axila/fisiopatología , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Femenino , Humanos , Lituania , Persona de Mediana Edad , Estadificación de Neoplasias/métodos , Estadificación de Neoplasias/normas , Estadificación de Neoplasias/estadística & datos numéricos , Periodo Preoperatorio , Biopsia del Ganglio Linfático Centinela/normas , Biopsia del Ganglio Linfático Centinela/estadística & datos numéricos , Ultrasonografía/normas , Ultrasonografía/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...