Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Eur J Cardiothorac Surg ; 52(2): 234-240, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28444210

RESUMEN

OBJECTIVES: We investigated the impact of initial shunt type, a Blalock-Taussig (BT) shunt versus a right ventricle to pulmonary artery conduit (RV-PA) on myocardial function at different stages of surgical palliation in patients with hypoplastic left heart syndrome (HLHS). METHODS: A population-based cohort of 63 Finnish children with HLHS (BT n = 23, RV-PA n = 40) born between 2003 and 2010 were studied retrospectively by echocardiography prior to Stages 1, 2 and 3 palliation and 0.5-3 years after Stage 3. For comparison of systolic myocardial function, we evaluated the RV fractional area change (FAC), strain, strain rate and mechanical synchrony from the apical 4-chamber view by velocity vector imaging. RESULTS: There were no intergroup differences in demographics during the study period. At baseline, no intergroup differences were detected in RV systolic myocardial function. Before Stage 2, RV FAC was higher ( P = 0.03) in the RV-PA conduit group. At Stage 3, an increase in all systolic myocardial functional parameters was observed in the BT shunt group. After Stage 3, the BT shunt group had better RV systolic function. In multiple regression analysis, the shunt type and the stage of palliation had an impact on myocardial function. CONCLUSIONS: Although patients with HLHS initially palliated with a BT shunt demonstrate lower RV FAC after Stage I, RV FAC improves after Stage 2 with better systolic performance after Stage 3 compared with those initially palliated with an RV-PA conduit.


Asunto(s)
Procedimiento de Blalock-Taussing/estadística & datos numéricos , Corazón/fisiopatología , Síndrome del Corazón Izquierdo Hipoplásico/epidemiología , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Procedimientos de Norwood/estadística & datos numéricos , Cateterismo Cardíaco , Preescolar , Ecocardiografía , Femenino , Corazón/diagnóstico por imagen , Humanos , Síndrome del Corazón Izquierdo Hipoplásico/diagnóstico por imagen , Lactante , Recién Nacido , Masculino , Procedimientos de Norwood/instrumentación , Cuidados Paliativos , Estudios Retrospectivos
2.
Echocardiography ; 34(4): 587-593, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28191731

RESUMEN

BACKGROUND: Quantitative echocardiographic assessment of right ventricular function is important in children with hypoplastic left heart syndrome (HLHS). The aim of this study was to examine the repeatability of different echocardiographic techniques, both manual and automated, to measure fractional area change (FAC) in patients with HLHS and to correlate these measurements with magnetic resonance imaging (MRI)-derived ejection fraction (EF). METHODS: Fifty-one children with HLHS underwent transthoracic echocardiography and cardiac MRI under the same general anesthetic as part of routine inter-stage assessment. FAC was measured from the apical four-chamber view using three different techniques: velocity vector imaging (VVI) (Syngo USWP 3.0; Siemens Healthineers), QLAB (Q-lab R 10.0; Philips Healthcare), and manual endocardial contour tracing (Xcelera, Philips Healthcare). Intra- and inter-observer variability was calculated using intra-class correlation coefficient (ICC). FAC was correlated with MRI EF calculated using a single standard method. RESULTS: Fractional area change had a good correlation with MRI-derived EF with an R value for VVI, QLAB, and manual methods of .7, .6, and .4, respectively. Intra- and inter-observer variability for FAC was good for automated echocardiographic methods (ICC>.85) but worse for manual method particularly inter-observer variability of FAC and end-systolic area. Both automated techniques tended to produce higher FAC values compared with manual measurements (P<.001). CONCLUSION: Automation improves the repeatability of FAC in HLHS. There are some differences between automated software in terms of correlation with MRI-derived EF. Measurement bias and wide limits of agreement mean that the same echocardiographic technique should be used during the follow-up of individual patients.


Asunto(s)
Ecocardiografía/métodos , Síndrome del Corazón Izquierdo Hipoplásico/complicaciones , Procesamiento de Imagen Asistido por Computador/métodos , Disfunción Ventricular Derecha/complicaciones , Disfunción Ventricular Derecha/diagnóstico por imagen , Adolescente , Niño , Preescolar , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Síndrome del Corazón Izquierdo Hipoplásico/fisiopatología , Lactante , Imagen por Resonancia Magnética , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Programas Informáticos , Disfunción Ventricular Derecha/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...