Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Phys Med ; 121: 103356, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38603998

RESUMEN

PURPOSE: Shear-wave elastography (SWE) provides quantitative and absolute metrics for analyzing the elasticity of soft tissues. Despite the anterior scalene muscle (AS) is a key structure in patients with neck pain and nerve compressive syndromes, the majority of SWE studies only included asymptomatic subjects. This study aimed to analyze the Young's modulus and shear wave speed test-retest reliability in a sample of patients with neck pain symptoms to characterize the AS stiffness. METHODS: A diagnostic accuracy study acquiring a set of ultrasound images at C7 level in 42 patients with mechanical neck pain by one experienced examiner. After blinding the participants' identity, trial and side, the Young's modulus and shear wave velocity were measured by an independent experienced rater in randomized order. Intra-class correlation coefficients (ICC), standard error of measurement (SEM), minimal detectable changes (MDC) and coefficient of variation (CV%) were calculated. RESULTS: The sample reported moderate pain intensity (5.9/10 points) and disability (17.38/100 points). AS stiffness metrics assessed showed no significant differences between males and females, left and right side nor painful and non-painful side. (all, p > 0.05). Intra-examiner reliability was excellent for calculating the Young's modulus for shear wave speed (ICC > 0.90). CONCLUSION: The results support the use of this procedure for assessing the AS stiffness in populations with mechanical neck pain as excellent reliability estimates were obtained. However, future research should analyze case-control differences and the association between SWE metrics with clinical severity indicators.


Asunto(s)
Módulo de Elasticidad , Diagnóstico por Imagen de Elasticidad , Dolor de Cuello , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Masculino , Femenino , Adulto , Dolor de Cuello/diagnóstico por imagen , Dolor de Cuello/fisiopatología , Persona de Mediana Edad , Adulto Joven , Reproducibilidad de los Resultados
2.
Sensors (Basel) ; 24(1)2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38203140

RESUMEN

The levator scapulae muscle is a key structure in the etiopathology of neck and shoulder musculoskeletal pain. Although previous studies used shear-wave elastography (SWE) for characterizing this muscle elasticity, limited evidence assessed the inter-examiner reliability of this procedure. This study aimed to analyze the inter-examiner reliability for calculating Young's modulus and shear wave speed in a cohort of participants with and without chronic neck pain. A diagnostic accuracy study was conducted, acquiring a set of SWE images at the C5 level in participants with and without neck pain (n = 34 and 33, respectively) by two examiners (one experienced and one novel). After blinding the participants' identity, examiner involved, and side, the stiffness indicators were calculated by an independent rater in a randomized order. Intra-class correlation coefficients (ICC), standard error of measurement, minimal detectable changes, and coefficient of variation were calculated. Both cohorts had comparable sociodemographic characteristics (p > 0.05). No significant levator scapulae elasticity differences were found between genders, sides, or cohorts (all, p > 0.05). Inter-examiner reliability for calculating Young's modulus and shear wave speed was moderate-to-good for assessing asymptomatic individuals (ICC = 0.714 and 0.779, respectively), while poor-to-moderate in patients with neck pain (ICC = 0.461 and 0.546, respectively). The results obtained in this study support the use of this procedure for assessing asymptomatic individuals. However, reliability estimates were unacceptable to support its use for assessing elasticity in patients with chronic neck pain. Future studies might consider that the shear wave speed is more sensitive to detect real changes in comparison with Young's modulus.


Asunto(s)
Dolor de Cuello , Músculos Superficiales de la Espalda , Humanos , Femenino , Masculino , Dolor de Cuello/diagnóstico por imagen , Reproducibilidad de los Resultados , Músculos Superficiales de la Espalda/diagnóstico por imagen , Cuello , Correlación de Datos
3.
Ultraschall Med ; 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38000908

RESUMEN

PURPOSE: Although previous studies have highlighted the clinical relevance of the anterior scalene muscle (AS) in patients with neck pain or nerve compressive syndromes, evidence reporting the diagnostic accuracy of shear wave elastography (SWE) for assessing the AS stiffness properties is lacking. This study aimed to analyze the SWE inter-examiner reliability for calculating the Young's modulus and shear wave speed of the AS muscle in asymptomatic subjects. MATERIALS AND METHODS: Using a linear transducer, ultrasound images of the antero-lateral neck region at the C7 level were acquired in 35 healthy volunteers by one experienced examiner and one novice examiner. After codifying the images to blind the participants' identity, the trial, and the side, Young's modulus and shear wave speed were obtained by an independent experienced rater in randomized order. Intra-class correlation coefficients (ICC), standard error of measurement (SEM), minimal detectable changes (MDC), and coefficient of variation (CV%) were calculated. RESULTS: The assessed AS metrics showed no side-to-side differences (p>0.05). Sex differences were found for muscle size (p=0.002), but muscle brightness and stiffness were similar (p>0.05). Inter-examiner reliability was good for determining the AS muscle stiffness (ICC = 0.881 for Young's modulus and 0.850 for shear wave speed). CONCLUSION: The obtained results suggest that assessing the AS stiffness properties in asymptomatic subjects is a reliable procedure. Further studies should verify the SWE capacity for discriminating healthy and clinical populations and identify potential factors contributing to the variance of measurement errors.

4.
Sensors (Basel) ; 23(3)2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36772252

RESUMEN

Ultrasound imaging (US) is a biosensing technique that is widely used in several healthcare disciplines (including physiotherapy) for assessing multiple muscle metrics, such as muscle morphology and quality. Since all biosensors need to be tested in order to demonstrate their reliability, accuracy, sensitivity, and specificity, identifying factors that affect their diagnostic accuracy is essential. Since previous studies analyzed the impact of sociodemographic but not body composition characteristics in US errors, this study aimed to assess whether body composition metrics are associated with ultrasound measurement errors. B-mode images of the lumbar multifidus muscle at the L5 level were acquired and analyzed in 47 healthy volunteers by two examiners (one experienced and one novice). The cross-sectional area, muscle perimeter, and mean echo intensity were calculated bilaterally. A correlation analysis and a multivariate linear regression model were used for assessing the inter-examiner differences with respect to body composition metrics. The results demonstrated good-to-excellent reliability estimates for the cross-sectional area, muscle perimeter, aspect ratio, roundness, circularity, and mean brightness metrics (all ICC > 0.85). However, solidity showed unacceptable reliability (ICC < 0.7). Age, height, total lean mass, trunk lean mass, and water volume were associated with inter-examiner disagreement on mean echo intensity. Cross-sectional area, perimeter, and roundness measurement errors were associated with lean mass and water volume.


Asunto(s)
Región Lumbosacra , Músculos Paraespinales , Humanos , Músculos Paraespinales/diagnóstico por imagen , Músculos Paraespinales/anatomía & histología , Reproducibilidad de los Resultados , Ultrasonografía/métodos , Región Lumbosacra/diagnóstico por imagen , Composición Corporal
5.
Bioengineering (Basel) ; 10(2)2023 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-36829627

RESUMEN

Ultrasound imaging (US) is widely used in several healthcare disciplines (including physiotherapy) for assessing multiple muscle metrics such as muscle morphology and quality. Since measuring instruments are required to demonstrate their reliability, accuracy, sensitivity, and specificity prior to their use in clinical and research settings, identifying factors affecting their diagnostic accuracy is essential. Since previous studies analyzed the impact of sociodemographic but not body composition characteristics in US errors, this study aimed to assess whether body composition metrics are correlated with ultrasound measurement errors. B-mode images of the lumbar multifidus muscle at the fifth lumbar vertebral level (L5) were acquired and analyzed in 49 healthy volunteers by two examiners (one experienced and one novel). Cross-sectional area, muscle perimeter and mean echo intensity were calculated bilaterally. A multivariate correlation matrix was calculated for assessing the inter-examiner differences with body composition metrics. Results demonstrated excellent reliability (intraclass correlation coefficient, ICC > 0.9) for assessing the muscle cross-sectional area and perimeter, and good reliability for assessing the muscle shape and mean echo intensity (ICC > 0.7). Inter-examiner errors for estimating muscle size were correlated with participants' age (p value, p < 0.01), weight (p < 0.05), total and trunk lean mass (both, p < 0.01) and water volume (p < 0.05). Greater shape descriptors and mean brightness disagreements were correlated with older ages (p < 0.05) and total lean mass (p < 0.05). No correlations between age and body composition metrics were found (p > 0.05). This study found US to be a reliable tool for assessing muscle size, shape and mean brightness. Although aging showed no correlations with body composition changes in this sample, it was the main factor correlated with US measurement errors.

6.
Nutrients ; 14(11)2022 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-35684122

RESUMEN

Background: Health-related quality of life (HRQoL) allows knowing the subject's feelings in distress and well-being, as well as perception of current and future health. Objective: To assess associations between health-related quality of life, fitness status, and adherence to the Mediterranean diet in Spanish children and adolescents. Methods: A cross-sectional study was carried out in a sample of 305 (47.2% women) children and adolescents aged between 8 and 16 years, in the primary and secondary schools of the province of Ávila (central Spain) (NCT05380674). Subjects were classified according to their quality of life: group 1 (highest quality of life) > group 2 (medium quality of life) > group 3 (lowest quality of life). Results: More participants in group 1 showed higher adherence to Mediterranean diet (70.8%) than other groups (group 2: 55.0%; group 3: 43.4%). It was less likely to find optimal levels of muscle strength as quality of life decreased (OR; 95% CI: group 2: 0.535; 0.303−0.955; and group 3: 0.424; 0.234−0.768). Similar trends were found for speed and agility, but only group 3 showed significant results (OR; 95% CI: group 3: 0.297; 0.162−0.545). Flexibility was also the worst in groups 2 and 3 (OR; 95% CI: G2: 0.403; 0.213−0.762; and group 3: 0.520; 0.282−0.958). Conclusion: High fitness status and adherence to the Mediterranean diet were associated with improved health-related quality of life in schoolchildren of central Spain.


Asunto(s)
Dieta Mediterránea , Adolescente , Niño , Estudios Transversales , Ejercicio Físico , Femenino , Humanos , Masculino , Calidad de Vida , España , Encuestas y Cuestionarios
7.
Artículo en Inglés | MEDLINE | ID: mdl-34073782

RESUMEN

PURPOSE: To study the prevalence of UI in female athletes, the category of sports with the highest number of cases, the most incident risk factors and the bio-psycho-social consequences. METHODS: Preparation of a survey, based on two validated questionnaires answered by 63 participants, to carry out an analytical, transversal and observational study. All participants were European, adult, female athletes (mean age 30.78 years, standard deviation 12.16 years). RESULTS: UI has a high prevalence (44.4%) in female athletes (compared to 10% in non-athletes), being more frequent in those who practice long-distance running. As age and years of sport practice increase, the incidence of this pathology increases. Absorbent pads are used by more than half of women with incontinence, while the rest wet their underwear. Menopause, childbirth and surgery in the region are risk factors for UI, while the presence of urinary tract infections or candidiasis is not. The results state that urine loss does not cause anxiety or depression, but it does affect sporting life. CONCLUSIONS: The prevalence of UI in this study is very high and more common in female athletes and the incidence increases with age and other risk factors. The salient consequence of this study is that urine loss affects their sporting environment, but does not induce depression or anxiety.


Asunto(s)
Atletas , Incontinencia Urinaria , Adulto , Femenino , Humanos , Prevalencia , Factores de Riesgo , Encuestas y Cuestionarios , Incontinencia Urinaria/epidemiología , Incontinencia Urinaria/etiología
8.
Clin Case Rep ; 9(1): 450-456, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33489196

RESUMEN

After a physical therapy treatment on the injured knee and a biomechanical study of the position on the bicycle, the symptomatology of the patient's injured knee has improved.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...