1.
Proc Natl Acad Sci U S A ; 121(16): e2400203121, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38598338

RESUMEN

Viral outbreaks can cause widespread disruption, creating the need for diagnostic tools that provide high performance and sample versatility at the point of use with moderate complexity. Current gold standards such as PCR and rapid antigen tests fall short in one or more of these aspects. Here, we report a label-free and amplification-free nanopore sensor platform that overcomes these challenges via direct detection and quantification of viral RNA in clinical samples from a variety of biological fluids. The assay uses an optofluidic chip that combines optical waveguides with a fluidic channel and integrates a solid-state nanopore for sensing of individual biomolecules upon translocation through the pore. High specificity and low limit of detection are ensured by capturing RNA targets on microbeads and collecting them by optical trapping at the nanopore location where targets are released and rapidly detected. We use this device for longitudinal studies of the viral load progression for Zika and Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) infections in marmoset and baboon animal models, respectively. The up to million-fold trapping-based target concentration enhancement enables amplification-free RNA quantification across the clinically relevant concentration range down to the assay limit of RT-qPCR as well as cases in which PCR failed. The assay operates across all relevant biofluids, including semen, urine, and whole blood for Zika and nasopharyngeal and throat swab, rectal swab, and bronchoalveolar lavage for SARS-CoV-2. The versatility, performance, simplicity, and potential for full microfluidic integration of the amplification-free nanopore assay points toward a unique approach to molecular diagnostics for nucleic acids, proteins, and other targets.


Asunto(s)
Nanoporos , Infección por el Virus Zika , Virus Zika , Animales , ARN Viral/genética , ARN Viral/metabolismo , SARS-CoV-2/genética , SARS-CoV-2/metabolismo , Primates/genética , Virus Zika/genética , Sensibilidad y Especificidad , Técnicas de Amplificación de Ácido Nucleico
2.
bioRxiv ; 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37205466

RESUMEN

Despite many interventions, science education remains highly inequitable throughout the world. Among all life sciences fields, Bioinformatics and Computational Biology suffer from the strongest underrepresentation of racial and gender minorities. Internet-enabled project-based learning (PBL) has the potential to reach underserved communities and increase the diversity of the scientific workforce. Here, we demonstrate the use of lab-on-a-chip (LoC) technologies to train Latinx life science undergraduate students in concepts of computer programming by taking advantage of open-loop cloud-integrated LoCs. We developed a context-aware curriculum to train students at over 8,000 km from the experimental site. We showed that this approach was sufficient to develop programming skills and increase the interest of students in continuing careers in Bioinformatics. Altogether, we conclude that LoC-based Internet-enabled PBL can become a powerful tool to train Latinx students and increase the diversity in STEM.

3.
Biosensors (Basel) ; 12(9)2022 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-36140075

RESUMEN

We demonstrate an optofluidic device which utilizes the optical scattering and gradient forces for particle trapping in microchannels featuring 300 nm thick membranes. On-chip waveguides are used to direct light into microfluidic trapping channels. Radiation pressure is used to push particles into a protrusion cavity, isolating the particles from liquid flow. Two different designs are presented: the first exclusively uses the optical scattering force for particle manipulation, and the second uses both scattering and gradient forces. Trapping performance is modeled for both cases. The first design, referred to as the orthogonal force design, is shown to have a 80% capture efficiency under typical operating conditions. The second design, referred to as the gradient force design, is shown to have 98% efficiency under the same conditions.


Asunto(s)
Microfluídica , Pinzas Ópticas
4.
Micromachines (Basel) ; 13(5)2022 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-35630187

RESUMEN

We demonstrate a method for fabricating and utilizing an optofluidic particle manipulator on a silicon chip that features a 300 nm thick silicon dioxide membrane as part of a microfluidic channel. The fabrication method is based on etching silicon channels and converting the walls to silicon dioxide through thermal oxidation. Channels are encapsulated by a sacrificial polymer which fills the length of the fluid channel by way of spontaneous capillary action. The sacrificial material is then used as a mold for the formation of a nanoscale, solid-state, silicon dioxide membrane. The hollow channel is primarily used for fluid and particle transport but is capable of transmitting light over short distances and utilizes radiation pressure for particle trapping applications. The optofluidic platform features solid-core ridge waveguides which can direct light on and off of the silicon chip and intersect liquid channels. Optical loss values are characterized for liquid and solid-core structures and at interfaces. Estimates are provided for the optical power needed to trap particles of various sizes.

5.
IEEE Photonics J ; 14(1)2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34900090

RESUMEN

Integrated optofluidic biosensors can fill the need for sensitive, amplification-free, multiplex single molecule detection which is relevant for containing the spread of infectious diseases such as COVID-19. Here, we demonstrate a rapid sample-to-answer scheme that uses a field programmable gate array (FPGA) to enable live monitoring of single particle fluorescence analysis on an optofluidic chip. Fluorescent nanobeads flowing through a micro channel are detected with 99% accuracy and particle concentrations in clinically relevant ranges from 3.4×104 to 3.4 × 106/ml are determined within seconds to a few minutes without the need for post-experiment data extraction and analysis. In addition, other extract salient experimental parameters such as dynamic flow rate changes can be monitored in real time. The sensor is validated with real-time fluorescence detection of single bacterial plasmid DNA at attomolar concentrations, showing excellent promise for implementation as a point of care (POC) diagnostic tool.

6.
Biosens Bioelectron ; 194: 113588, 2021 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-34474277

RESUMEN

Ultrasensitive, versatile sensors for molecular biomarkers are a critical component of disease diagnostics and personalized medicine as the COVID-19 pandemic has revealed in dramatic fashion. Integrated electrical nanopore sensors can fill this need via label-free, direct detection of individual biomolecules, but a fully functional device for clinical sample analysis has yet to be developed. Here, we report amplification-free detection of SARS-CoV-2 RNAs with single molecule sensitivity from clinical nasopharyngeal swab samples on an electro-optofluidic chip. The device relies on optically assisted delivery of target carrying microbeads to the nanopore for single RNA detection after release. A sensing rate enhancement of over 2,000x with favorable scaling towards lower concentrations is demonstrated. The combination of target specificity, chip-scale integration and rapid detection ensures the practicality of this approach for COVID-19 diagnosis over the entire clinically relevant concentration range from 104-109 copies/mL.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Nanoporos , Prueba de COVID-19 , Humanos , Pinzas Ópticas , Pandemias , ARN Viral/genética , SARS-CoV-2
7.
Lab Chip ; 21(16): 3030-3052, 2021 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-34137407

RESUMEN

The advent of single-molecule probing techniques has revolutionized the biomedical and life science fields and has spurred the development of a new class of labs-on-chip based on powerful biosensors. Nanopores represent one of the most recent and most promising single molecule sensing paradigms that is seeing increased chip-scale integration for improved convenience and performance. Due to their physical structure, nanopores are highly sensitive, require low sample volume, and offer label-free, amplification-free, high-throughput real-time detection and identification of biomolecules. Over the last 25 years, nanopores have been extensively employed to detect a variety of biomolecules with a growing range of applicatons ranging from nucleic acid sequencing to ultrasensitive diagnostics to single-molecule biophysics. Nanopores, in particular those in solid-state membranes, also have the potential for integration with other technologies such as optics, plasmonics, microfluidics, and optofluidics to perform more complex tasks for an ever-expanding demand. A number of breakthrough results using integrated nanopore platforms have already been reported, and more can be expected as nanopores remain the focus of innovative research and are finding their way into commercial instruments. This review provides an overview of different aspects and challenges of nanopore technology with a focus on chip-scale integration of solid-state nanopores for biosensing and bioanalytical applications.


Asunto(s)
Técnicas Biosensibles , Nanoporos , Secuencia de Bases , Nanotecnología
8.
Nanotechnology ; 31(44): 445303, 2020 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-32679580

RESUMEN

We present a method to create robust, nanoscale solid-state membranes using the natural shape of a liquid meniscus as a template. A narrow, open channel is etched into a silicon substrate and then a photoresist polymer is introduced into the channel through spontaneous capillary action. The natural concave meniscus formed by the polymer is then covered by a thin chemical vapor deposited membrane. The polymer is removed by sacrificial etching, leaving behind a suspended membrane. Membranes as large as 20 µm by 9 mm can be fabricated with a thickness as low as 50 nm.

SELECCIÓN DE REFERENCIAS