Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
EJNMMI Radiopharm Chem ; 4(1): 24, 2019 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-31659546

RESUMEN

BACKGROUND: PET radiopharmaceutical development and the implementation of a production method on a synthesis module is a complex and time-intensive task since new synthesis methods must be adapted to the confines of the synthesis platform in use. Commonly utilized single fluid bus architectures put multiple constraints on synthesis planning and execution, while conventional microfluidic solutions are limited by compatibility at the macro-to-micro interface. In this work we introduce the ISAR synthesis platform and custom-tailored fluid paths leveraging up to 70 individually addressable valves on a chip-based consumable. The ISAR synthesis platform replaces traditional stopcock valve manifolds with a fluidic chip that integrates all fluid paths (tubing) and valves into one consumable and enables channel routing without the single fluid bus constraint. ISAR can scale between the macro- (10 mL), meso- (0.5 mL) and micro- (≤0.05 mL) domain seamlessly, addressing the macro-to-micro interface challenge and enabling custom tailored fluid circuits for a given application. In this paper we demonstrate proof-of-concept by validating a single chip design to address the challenge of synthesizing multiple batches of [13N]NH3 for clinical use throughout the workday. RESULTS: ISAR was installed at an academic PET Center and used to manufacture [13N]NH3 in > 96% radiochemical yield. Up to 9 batches were manufactured with a single consumable chip having parallel paths without the need to open the hot-cell. Quality control testing confirmed the ISAR-based [13N]NH3 met existing clinical release specifications, and utility was demonstrated by imaging a rodent with [13N]NH3 produced on ISAR. CONCLUSIONS: ISAR represents a new paradigm in radiopharmaceutical production. Through a new system architecture, ISAR integrates the principles of microfluidics with the standard volumes and consumables established in PET Centers all over the world. Proof-of-concept has been demonstrated through validation of a chip design for the synthesis of [13N]NH3 suitable for clinical use.

2.
Lab Chip ; 14(14): 2556-64, 2014 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-24879121

RESUMEN

The application of microfluidics to the synthesis of Positron Emission Tomography (PET) tracers has been explored for more than a decade. Microfluidic benefits such as superior temperature control have been successfully applied to PET tracer synthesis. However, the design of a compact microfluidic platform capable of executing a complete PET tracer synthesis workflow while maintaining prospects for commercialization remains a significant challenge. This study uses an integral system design approach to tackle commercialization challenges such as the material to process compatibility with a path towards cost effective lab-on-chip mass manufacturing from the start. It integrates all functional elements required for a simple PET tracer synthesis into one compact radiochemistry platform. For the lab-on-chip this includes the integration of on-chip valves, on-chip solid phase extraction (SPE), on-chip reactors and a reversible fluid interface while maintaining compatibility with all process chemicals, temperatures and chip mass manufacturing techniques. For the radiochemistry device it includes an automated chip-machine interface enabling one-move connection of all valve actuators and fluid connectors. A vial-based reagent supply as well as methods to transfer reagents efficiently from the vials to the chip has been integrated. After validation of all those functional elements, the microfluidic platform was exemplarily employed for the automated synthesis of a Gastrin-releasing peptide receptor (GRP-R) binding the PEGylated Bombesin BN(7-14)-derivative ([(18)F]PESIN) based PET tracer.


Asunto(s)
Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas , Radioquímica , Radiofármacos , Bombesina/química , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/métodos , Trazadores Radiactivos , Radioquímica/instrumentación , Radioquímica/métodos , Radiofármacos/síntesis química , Radiofármacos/química , Receptores de Bombesina/química
3.
Molecules ; 18(7): 7930-56, 2013 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-23884128

RESUMEN

Application of microfluidics to Positron Emission Tomography (PET) tracer synthesis has attracted increasing interest within the last decade. The technical advantages of microfluidics, in particular the high surface to volume ratio and resulting fast thermal heating and cooling rates of reagents can lead to reduced reaction times, increased synthesis yields and reduced by-products. In addition automated reaction optimization, reduced consumption of expensive reagents and a path towards a reduced system footprint have been successfully demonstrated. The processing of radioactivity levels required for routine production, use of microfluidic-produced PET tracer doses in preclinical and clinical imaging as well as feasibility studies on autoradiolytic decomposition have all given promising results. However, the number of microfluidic synthesizers utilized for commercial routine production of PET tracers is very limited. This study reviews the state of the art in microfluidic PET tracer synthesis, highlighting critical design aspects, strengths, weaknesses and presenting several characteristics of the diverse PET market space which are thought to have a significant impact on research, development and engineering of microfluidic devices in this field. Furthermore, the topics of batch- and single-dose production, cyclotron to quality control integration as well as centralized versus de-centralized market distribution models are addressed.


Asunto(s)
Microfluídica/métodos , Tomografía de Emisión de Positrones , Trazadores Radiactivos , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentación , Control de Calidad , Radioisótopos , Radiofármacos/síntesis química
4.
Appl Radiat Isot ; 70(8): 1691-7, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22750198

RESUMEN

Autoradiolysis describes the degradation of radioactively labeled compounds due to the activity of the labeled compounds themselves. It scales with activity concentration and is of importance for high activity and microfluidic PET tracer synthesis. This study shows that microfluidic devices can be shaped to reduce autoradiolysis by geometric exclusion of positron interaction. A model is developed and confirmed by demonstrating in-capillary storage of non-stabilized [(18)F]FDG (2-[(18)F]Fluoro-2-deoxy-d-glucose) at max. 23 GBq/ml while maintaining >90% radiochemical purity over 14 h.


Asunto(s)
Microfluídica/instrumentación , Radiofármacos/química , Modelos Teóricos , Método de Montecarlo , Tomografía de Emisión de Positrones
5.
Biomed Microdevices ; 10(2): 251-7, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17914675

RESUMEN

This paper reports on the comparison analysis of four main types of silicon-based microfilter for isolation of white blood cells (WBCs) from red blood cells (RBCs) in a given whole blood. The microfilter designs, namely, weir, pillar, crossflow, and membrane, all impose the same cut-off size of 3.5 mum to selectively trap WBCs. Using human whole blood, the microfilters have been characterized and compared for their blood handling capacity, WBCs trapping efficiency and RBCs passing efficiency. Based on the experimental results, the crossflow microfilter is superior and can be integrated with downstream components for on-chip genomic analysis.


Asunto(s)
Células Sanguíneas/citología , Técnicas de Cultivo de Célula/instrumentación , Separación Celular/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Silicio/química , Ultrafiltración/instrumentación , Técnicas de Cultivo de Célula/métodos , Separación Celular/métodos , Células Cultivadas , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Técnicas Analíticas Microfluídicas/métodos , Ultrafiltración/métodos
6.
Tissue Eng ; 13(9): 2345-56, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17708717

RESUMEN

Innovative scaffold fabrication, angiogenesis promotion, and dynamic tissue culture techniques have been utilized to improve delivery of media into the core of large tissue constructs in tissue engineering. We have developed here an intra-tissue perfusion (ITP) system, which incorporates an array of seven micron-sized needles as a delivery conduit, to improve mass transfer into the core of thick liver tissues slices (>>300 microm mass transport limit). The ITP system improves the uniformity and distribution of media throughout the tissue, resulting in improved cell viability over the static-cultured controls. The ITP-cultured thick liver slices also exhibit improved phase I and phase II metabolic functions and albumin and urea synthetic functions after 3-day culture, which is the minimal period required by the U.S. Food and Drug Administration (FDA) for studying drug-drug interaction. This ITP system can also be used for culturing other thick tissue constructs of larger dimensions for various in vitro and in vivo applications, including bridging integration of the in vitro cultured constructs into living host tissues.


Asunto(s)
Hígado , Técnicas de Cultivo de Órganos/instrumentación , Perfusión/instrumentación , Animales , Cámaras de Difusión de Cultivos , Hígado/citología , Hígado/metabolismo , Masculino , Ratas , Ratas Wistar
7.
Lab Chip ; 7(3): 302-9, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17330160

RESUMEN

Mammalian cells cultured on 2D surfaces in microfluidic channels are increasingly used in drug development and biological research applications. These systems would have more biological or clinical relevance if the cells exhibit 3D phenotypes similar to the cells in vivo. We have developed a microfluidic channel based system that allows cells to be perfusion-cultured in 3D by supporting them with adequate 3D cell-cell and cell-matrix interactions. The maximal cell-cell interaction was achieved by perfusion-seeding cells through an array of micropillars; and 3D cell-matrix interactions were achieved by a polyelectrolyte complex coacervation process to form a thin layer of matrix conforming to the 3D cell shapes. Carcinoma cell lines (HepG2, MCF7), primary differentiated (hepatocytes) and primary progenitor cells (bone marrow mesenchymal stem cells) were perfusion-cultured for 72 hours to 1 week in the microfluidic channel, which preserved their 3D cyto-architecture and cell-specific functions or differentiation competence. This transparent 3D microfluidic channel-based cell culture system also allows direct optical monitoring of cellular events for a wide range of applications.


Asunto(s)
Microfluídica/métodos , Animales , Células de la Médula Ósea/citología , Células de la Médula Ósea/ultraestructura , Técnicas de Cultivo de Célula , Hepatocitos/citología , Hepatocitos/ultraestructura , Masculino , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/ultraestructura , Microscopía Confocal , Microscopía Electrónica de Rastreo , Perfusión , Ratas , Ratas Wistar
8.
Biomed Microdevices ; 8(2): 151-8, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16688574

RESUMEN

A novel microfluidic platform for manipulation of micro/nano magnetic particles was designed, fabricated and tested for applications dealing with biomolecular separation. Recently, magnetic immunomagnetic cell separation has attracted a noticeable attention due to the high selectivity of such separation methods. Strong magnetic field gradients can be developed along the entire wire, and the miniaturized size of these current-carrying conductors strongly enhances the magnetic field gradient and therefore produces large, tunable and localized magnetic forces that can be applied on magnetic particles and confine them in very small spots. Further increases in the values of the generated magnetic field gradients can be achieved by employing miniaturized ferromagnetic structures (pillars) which can be magnetized by an external magnetic field or by micro-coils on the same chip. In this study, we demonstrate magnetic beads trapping, concentration, transportation and sensing in a liquid sample under continuous flow by employing high magnetic field gradients generated by novel multi-functional magnetic micro-devices. Each individual magnetic micro-device consists of the following components: 1. Cu micro-coils array embedded in the silicon substrate with high aspect ratio conductors for efficient magnetic field generation 2. Magnetic pillar(s) made of the magnetic alloy NiCoP for magnetic field focusing and magnetic field gradient enhancement. Each pillar is magnetized by its corresponding coil 3. Integrated sensing coil for magnetic beads detection 4. Microfluidic chamber containing all the previous components. Magnetic fields of about 0.1 T and field gradients of around 300 T/cm have been achieved, which allowed to develop a magnetic force of 3 x 10(-9) N on a magnetic particle with radius of 1 mum. This force is large enough to trap/move this particle as the required force to affect such particles in a liquid sample is on the order of approximately pN. Trapping rates of up to 80% were achieved. Furthermore, different micro-coil designs were realized which allowed various movement modes and with different step-sizes. These results demonstrate that such devices incorporated within a microfluidic system can provide significantly improved spatial resolution and force magnitude for quick, efficient and highly selective magnetic trapping, separation and transportation, and as such they are an excellent solution for miniaturized mu-total analysis systems.


Asunto(s)
Biopolímeros/aislamiento & purificación , Biopolímeros/efectos de la radiación , Mezclas Complejas/aislamiento & purificación , Análisis de Inyección de Flujo/instrumentación , Separación Inmunomagnética/instrumentación , Magnetismo , Técnicas Analíticas Microfluídicas/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Análisis de Inyección de Flujo/métodos , Separación Inmunomagnética/métodos , Miniaturización
9.
Biosens Bioelectron ; 21(9): 1693-702, 2006 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-16203127

RESUMEN

An innovative microfluidic platform for magnetic beads manipulation is introduced, consisting of novel microfabricated 3D magnetic devices positioned in a microfluidic chamber. Each magnetic device comprises of an embedded actuation micro-coil in various design versions, a ferromagnetic pillar, a magnetic backside plate and a sensing micro-coil. The various designs of the micro-coils enable efficient magnetic beads trapping and concentration in different patterns. The finite element analysis (FEA) results show a significant increase of the developed force on suspended magnetic beads when the magnetic pillar and backside plate were integrated into the device structure. These simulation results were confirmed experimentally by measuring the magnetic beads trapping ratios for the different designs and structures of the devices under continuous flow conditions. The trapping ratios and profiles were studied using beads counting, measuring the change of inductance with the sensing micro-coil and by image processing. The devices have efficiently demonstrated a controlled and localized magnetic beads trapping and concentration at small spatial locations for the first time. The new results shown in this study demonstrate the feasibility of efficiently using these original devices as key elements in complex bio-analysis systems.


Asunto(s)
Separación Inmunomagnética/instrumentación , Magnetismo/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Separación Inmunomagnética/métodos , Técnicas Analíticas Microfluídicas/métodos , Microesferas , Integración de Sistemas
10.
Biophys J ; 89(2): L14-7, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15980177

RESUMEN

The extraordinary climbing skills of gecko lizards have been under investigation for a long time. Here we report results of direct measurement of single spatula forces in air with varying relative humidities and in water, by the force-distance method using an atomic force microscope. We have found that the presence of water strongly affects the adhesion force and from analysis of our results, we have demonstrated that the dominant force involved is the capillary force.


Asunto(s)
Epidermis/fisiología , Epidermis/ultraestructura , Pie/anatomía & histología , Pie/fisiología , Lagartos/anatomía & histología , Lagartos/fisiología , Locomoción/fisiología , Modelos Biológicos , Adhesividad , Animales , Simulación por Computador , Microscopía de Fuerza Atómica/métodos , Estrés Mecánico
11.
Assay Drug Dev Technol ; 3(2): 169-76, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15871691

RESUMEN

We have developed a technique for the in situ three-dimensional (3D) immobilization of primary rat hepatocytes within a localized matrix in a microfluidic channel that provides a 3D microenvironment incorporating both a configurable 3D matrix and fluid perfusion. This is based on the laminar flow complex coacervation of a pair of oppositely charged polyelectrolytes, i.e., methylated collagen and a terpolymer of HEMA-MMA-MAA. 3D collagen matrices were formed with minimal gelation times (<8 min), were able to entrap cells under aqueous noncytotoxic conditions, and permitted culture media to be perfused in the microchannel by virtue of the spatial confinement of the 3D matrix on one side of the channel. The architecture and stability of the collagen matrix could be configured by the use of different material combinations and changes in the polyelectrolyte flow rates and retention time. Primary rat hepatocytes cultured for 24 h in the 3D matrix within the microchannel showed comparable or enhanced cytochrome P450 7-ethoxyresorufin-O-deethylation activity with static controls. The configurable 3D microenvironment in the microfluidic channel may be a potential 3D culture model of primary hepatocytes for drug testing applications.


Asunto(s)
Bioensayo/métodos , Técnicas de Cultivo de Célula/métodos , Análisis de Inyección de Flujo/métodos , Hepatocitos/citología , Hepatocitos/fisiología , Técnicas Analíticas Microfluídicas/métodos , Animales , Bioensayo/instrumentación , Técnicas de Cultivo de Célula/instrumentación , Células Inmovilizadas/citología , Células Inmovilizadas/fisiología , Sistema Enzimático del Citocromo P-450/metabolismo , Diseño de Equipo , Análisis de Falla de Equipo , Análisis de Inyección de Flujo/instrumentación , Masculino , Técnicas Analíticas Microfluídicas/instrumentación , Ratas , Ratas Wistar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA