Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Ann Thorac Surg ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38763221

RESUMEN

BACKGROUND: Limited data exist on the long-term outcomes of transcatheter aortic valve insertion (TAVI) in nonagenarian patients. This study investigated the relationship between patient baseline comorbidity and frailty on the long-term outcome of the nonagenarian population. METHODS: A retrospective analysis was conducted of 187 consecutive nonagenarian patients who underwent TAVI from 2009 to 2020. Multivariable models were used to analyze the association between baseline patient and frailty variables and mortality, stroke, and repeat hospitalization. Long-term survival was compared with an age- and sex-matched United States population. RESULTS: The median Society of Thoracic Surgeons predicted risk of mortality was 10% (interquartile range, 7%-17%). Frailty was met in 72% of patients based on the 5-meter walk test, 13% based on the Kansas City Cardiomyopathy Questionnaire 12-item instrument score, 12% based on Katz Index of Independence in Activities of Daily Living, and 8% based on serum albumin levels. Procedure-related death occurred in 3 patients (2%) and stroke in 8 (4%). The median duration of follow-up was 3.4 years. Outcomes included death in 150 patients (80%), stroke in 15, and repeat hospitalization in 114. Multivariable analysis identified no association between any of the baseline patient variables with mortality, stroke, repeat hospitalization, or the combined outcomes (all P > .05). The 1- and 5-year survival rates in TAVI-treated nonagenarians were similar to age- and sex-matched controls (P = .27). CONCLUSIONS: Long-term death or stroke is independent of The Society of Thoracic Surgeons predicted risk of mortality and frailty risk variables in this nonagenarian patient population who received TAVI. Furthermore, survival is similar to age- and sex-matched controls.

2.
Tissue Eng Part A ; 29(15-16): 413-423, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37130041

RESUMEN

Recruitment of endothelial cells to cardiovascular device surfaces could solve issues of thrombosis, neointimal hyperplasia, and restenosis. Since current targeting strategies are often nonspecific, new technologies to allow for site-specific cell localization and capture in vivo are needed. The development of cytocompatible superparamagnetic iron oxide nanoparticles has allowed for the use of magnetism for cell targeting. In this study, a magnetic polyurethane (PU)-2205 stainless steel (2205-SS) nanofibrous composite biomaterial was developed through analysis of composite sheets and application to stent-grafts. The PU nanofibers provide strength and elasticity while the 2205-SS microparticles provide ferromagnetic properties. Sheets were electrospun at mass ratios of 0-4:1 (2205-SS:PU) and stent-grafts with magnetic or nonmagnetic stents were coated at the optimal ratio of 2:1. These composite materials were characterized by microscopy, mechanical testing, a sessile drop test, magnetic field measurement, magnetic cell capture assays, and cytocompatibility after 14 days of culturing with endothelial cells. Results of this study show that an optimal ratio of 2:1 2205-SS:PU results in a hydrophobic material that balanced mechanical and magnetic properties and was cytocompatible up to 14 days. Significant cell capture required a thicker material of 0.5 mm thickness. Stent-grafts fabricated from a magnetic coating and a magnetic stent demonstrated uniform cell capture throughout the device surface. This novel biomaterial exhibits a combination of mechanical and magnetic properties that enables magnetic capture of cells and other therapeutic agents for vascular and other tissue engineering applications.


Asunto(s)
Materiales Biocompatibles , Nanofibras , Materiales Biocompatibles/farmacología , Materiales Biocompatibles/química , Ingeniería de Tejidos , Nanofibras/química , Poliuretanos/farmacología , Células Endoteliales , Fenómenos Magnéticos , Materiales Biocompatibles Revestidos/química
3.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-36645236

RESUMEN

OBJECTIVES: Low forced expiratory volume in 1 s (FEV1) and elevated N-terminal pro-B-type natriuretic peptide (NT-Pro-BNP) have been individually associated with poor outcomes after transcatheter aortic valve replacement (TAVR). We hypothesized a combination of the 2 would provide prognostic indication after TAVR. METHODS: We categorized 871 patients who received TAVR from 2008 to 2018 into 4 groups according to baseline FEV1 (<60% or ≥60% predicted) and NT-Pro-BNP (<1601 or ≥1601 pg/ml): group A (n = 312, high FEV1, low NT-Pro-BNP), group B (n = 275, high FEV1, high NT-Pro-BNP), group C (n = 123 low FEV1, low NT-Pro-BNP) and group D (n = 161, low FEV1, high NT-Pro-BNP). The primary end point was survival at 1 and 5 years. RESULTS: Patients in group A had more severe aortic stenosis and achieved the best long-term survival at 1 [93% (95% CI: 90-96)] and 5 [45.3% (95% CI: 35.4-58)] years. Low FEV1 and high NT-Pro-BNP (group D) patients had more severe symptoms, higher Society of Thoracic Surgeons predicted risk of operative mortality, lower ejection fraction and aortic valve gradient at baseline. Patients in group D had the worst survival at 1 [76% (95% CI: 69-83)] and 5 years [13.1% (95% CI: 7-25)], hazard ratio compared to group A: 2.29 (95% CI: 1.6-3.2, P < 0.001) with 25.7% of patients in New York Heart Association class III-IV. Patients in groups B and C had intermediate outcomes. CONCLUSIONS: The combination of FEV1 and NT-Pro-BNP stratifies patients into 4 groups with distinct risk profiles and clinical outcomes. Patients with low FEV1 and high NT-Pro-BNP have increased comorbidities, poor functional outcomes and decreased long-term survival after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Péptido Natriurético Encefálico , Volumen Espiratorio Forzado , Pronóstico , Fragmentos de Péptidos , Biomarcadores , Válvula Aórtica/cirugía
4.
iScience ; 25(11): 105409, 2022 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-36388965

RESUMEN

The airway epithelium is a protective barrier that is maintained by the self-renewal and differentiation of basal stem cells. Increasing age is a principle risk factor for chronic lung diseases, but few studies have explored age-related molecular or functional changes in the airway epithelium. We retrieved epithelial biopsies from histologically normal tracheobronchial sites from pediatric and adult donors and compared their cellular composition and gene expression profile (in laser capture-microdissected whole epithelium, fluorescence-activated cell-sorted basal cells, and basal cells in cell culture). Histologically, pediatric and adult tracheobronchial epithelium was similar in composition. We observed age-associated changes in RNA sequencing studies, including higher interferon-associated gene expression in pediatric epithelium. In cell culture, pediatric cells had higher colony formation ability, sustained in vitro growth, and outcompeted adult cells in a direct competitive proliferation assay. Our results demonstrate cell-intrinsic differences between airway epithelial cells from children and adults in both homeostatic and proliferative states.

5.
Am J Cardiol ; 167: 118-124, 2022 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-35031110

RESUMEN

This study aimed to evaluate the use and frequency of complementary and integrative medicine (CIM) therapies in an outpatient cohort with cardiovascular disease (CVD) and compare trends over time. This cross-sectional point-of-care prospective study assessed patients attending a cardiology outpatient clinic. As in our 2009 cohort, data were collected with a 17-question survey on demographic characteristics, CVD history, current use and future interest in CIM. In total, 964 patients completed the survey. CIM use continues to be high (2009 vs 2018, 83.4% vs 81.8%) (p = 0.34), with dietary supplements the most common therapy (75% in both studies). We observed increased use of mind-body therapies (28.5% vs 23.9%, p = 0.02), especially meditation, yoga, and tai chi. Of the patients receiving CIM therapies, 41.9% reported using CIM for heart-related symptoms. Relaxation, stress management, and meditation were the top three mind-body therapies for CVD-related symptoms in both cohorts. Reporting of CIM use to clinicians is low (15%) and interest on future use is high (47%). In conclusion, CIM is highly used in cardiology patients-4 of 10 patients use CIM for CVD-related symptoms. Most take dietary supplements, with an increased use of mind-body therapies. Our data highlight the importance of documenting CIM use in practice and the need for research to document efficacy.


Asunto(s)
Enfermedades Cardiovasculares , Terapias Complementarias , Medicina Integrativa , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/terapia , Estudios Transversales , Humanos , Estudios Prospectivos
6.
J Vis Exp ; (179)2022 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-35068481

RESUMEN

The endothelium is a dynamic integrated structure that plays an important role in many physiological functions such as angiogenesis, hemostasis, inflammation, and homeostasis. The endothelium also plays an important role in pathophysiologies such as atherosclerosis, hypertension, and diabetes. Endothelial cells form the inner lining of blood and lymphatic vessels and display heterogeneity in structure and function. Various groups have evaluated the functionality of endothelial cells derived from human peripheral blood with a focus on endothelial progenitor cells derived from hematopoietic stem cells or mature blood outgrowth endothelial cells (or endothelial colony-forming cells). These cells provide an autologous resource for therapeutics and disease modeling. Xenogeneic cells may provide an alternative source of therapeutics due to their availability and homogeneity achieved by using genetically similar animals raised in similar conditions. Hence, a robust protocol for the isolation and expansion of highly proliferative blood outgrowth endothelial cells from porcine peripheral blood has been presented. These cells can be used for numerous applications such as cardiovascular tissue engineering, cell therapy, disease modeling, drug screening, studying endothelial cell biology, and in vitro co-cultures to investigate inflammatory and coagulation responses in xenotransplantation.


Asunto(s)
Aterosclerosis , Células Progenitoras Endoteliales , Animales , Coagulación Sanguínea , Tratamiento Basado en Trasplante de Células y Tejidos , Porcinos , Ingeniería de Tejidos/métodos
7.
Semin Thorac Cardiovasc Surg ; 34(1): 80-89, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33691188

RESUMEN

The survival benefits of pulmonary thromboendarterectomy (PTE) for the treatment of chronic thromboembolic pulmonary hypertension have been well described. However, the significance of right heart hemodynamic changes and their impact on survival remains poorly understood. We sought to characterize the effects of these changes. We conducted a single center, retrospective review of 159 patients who underwent PTE between 1993 and 2015. Echocardiographic and right heart catheterization data were compared longitudinally before and after PTE in order to establish the extent of hemodynamic response to surgery. Kaplan Meier estimates were used to characterize patient survival over time. Univariable and multivariable Cox proportional hazards regression models were used to assess factors associated with long-term mortality. Among the 159 patients studied, 74 (46.5%) were male with a median age of 55 (IQR: 42-66). One-, 5-, 10-, and 15-year survival was 91.0% (95% CI: 86.6-95.6), 79.6% (73.5-86.3), 66.5% (59.2-74.7), and 56.2% (48.1-65.8). Of the 9 candidate risk factors that were evaluated, only advanced age and increased cardiopulmonary bypass time were found to be significantly associated with increased risk of mortality. Pre- and postsurgical echocardiographic imaging data, when available, revealed a median reduction in right ventricular systolic pressure of 29.0 mm Hg (P < 0.0001) and improvement of tricuspid regurgitation (P < 0.0001), both of which appeared to be sustained across long-term follow-up. Improvements in right heart hemodynamics and tricuspid valvular regurgitation persist on long term surveillance following PTE. While patient selection is often driven by the distribution of disease, close postoperative follow up may improve outcomes.


Asunto(s)
Hipertensión Pulmonar , Embolia Pulmonar , Insuficiencia de la Válvula Tricúspide , Enfermedad Crónica , Endarterectomía/efectos adversos , Hemodinámica , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/cirugía , Masculino , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/cirugía , Resultado del Tratamiento
8.
J Am Soc Echocardiogr ; 35(1): 116-123, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34506919

RESUMEN

BACKGROUND: Doppler mean gradient (MG) may underestimate aortic stenosis (AS) severity when obtained during atrial fibrillation (AF) because of lower forward flow compared with sinus rhythm (SR). Whether AS is more advanced at the time of referral for aortic valve intervention in AF compared with SR is unknown. The aim of this study was to examine flow-independent computed tomographic aortic valve calcium scores (AVCS) and their concordance to MG in AF versus SR in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: Patients who underwent TAVR from 2016 to 2020 for native valve severe AS with left ventricular ejection fraction ≥ 50% were identified from an institutional TAVR database. MGs during AF and SR in high-gradient AS (HGAS) and low-gradient AS (LGAS) were compared with AVCS (AVCS/MG ratio). AVCS were obtained within 90 days of pre-TAVR echocardiography. RESULTS: Six hundred thirty-three patients were included; median age was 82 years (interquartile range [IQR], 76-86 years), and 46% were women. AF was present in 109 (17%) and SR in 524 (83%) patients during echocardiography. Aortic valve area index was slightly smaller in AF versus SR (0.43 cm2/m2 [IQR, 0.39-0.47 cm2/m2] vs 0.46 cm2/m2 [IQR, 0.41-0.51 cm2/m2], P = .0003). Stroke volume index, transaortic flow rate, and MG were lower in AF (P < .0001 for all). AVCS were higher in men with AF compared with SR (3,510 Agatston units [AU] [IQR, 2,803-4,030 AU] vs 2,722 AU [IQR, 2,180-3,467 AU], P < .0001) in HGAS but not in LGAS. AVCS were not different in women with AF versus SR. Overall AVCS/MG ratios were higher in AF versus SR in HGAS and LGAS (P < .03 for all), except in women with LGAS. CONCLUSIONS: AVCS were higher than expected by MG in AF compared with SR. The very high AVCS in men with AF and HGAS at the time of TAVR suggests late diagnosis of severe AS because of underestimated AS severity during progressive AS and/or late referral to TAVR. Additional studies are needed to examine the extent to which echocardiography may be underestimating AS severity in AF.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Calcio , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
9.
Am Heart J ; 244: 54-65, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34774802

RESUMEN

OBJECTIVE: To evaluate the epidemiology and outcomes of non-ST-segment-elevation myocardial infarction-cardiogenic shock (NSTEMI-CS) in the United States. METHODS: Adult (>18 years) NSTEMI-CS admissions were identified using the National Inpatient Sample (2000-2017) and classified by tertiles of admission year (2000-2005, 2006-2011 and 2012-2017). Outcomes of interest included temporal trends of prevalence and in-hospital mortality, use of cardiac procedures, in-hospital mortality, hospitalization costs, and length of stay. RESULTS: In over 7.3 million NSTEMI admissions, CS was noted in 189,155 (2.6%). NSTEMI-CS increased from 1.5% in 2000 to 3.6% in 2017 (adjusted odds ratio 2.03 [95% confidence interval 1.97-2.09]; P < .001). Rates of non-cardiac organ failure and cardiac arrest increased during the study period. Between 2000 and 2017, coronary angiography (43.9%-63.9%), early coronary angiography (13.6%-25.6%), percutaneous coronary intervention (14.8%-31.6%), and coronary artery bypass grafting use (19.0%-25.8%) increased (P < .001). Over the study period, the use of intra-aortic balloon pump remained stable (28.6%-28.8%), and both percutaneous left ventricular assist devices (0%-9.1%) and extra-corporeal membrane oxygenation (0.1%-1.6%) increased (all P < .001). In hospital mortality decreased from 50.2% in 2000 to 32.3% in 2017 (adjusted odds ratio 0.27 [95% confidence interval 0.25-0.29]; P < .001). During the 18-year period, hospital lengths of stay decreased, and hospitalization costs increased. CONCLUSIONS: In the United States, prevalence of CS in NSTEMI has increased 2-fold between 2000 and 2017, while in-hospital mortality has decreased during the study period. Use of coronary angiography and percutaneous coronary intervention increased during the study period.


Asunto(s)
Infarto del Miocardio sin Elevación del ST , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Adulto , Mortalidad Hospitalaria , Humanos , Contrapulsador Intraaórtico/efectos adversos , Infarto del Miocardio sin Elevación del ST/complicaciones , Infarto del Miocardio sin Elevación del ST/diagnóstico , Infarto del Miocardio sin Elevación del ST/epidemiología , Intervención Coronaria Percutánea/efectos adversos , Infarto del Miocardio con Elevación del ST/complicaciones , Infarto del Miocardio con Elevación del ST/epidemiología , Infarto del Miocardio con Elevación del ST/terapia , Choque Cardiogénico/epidemiología , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Estados Unidos/epidemiología
10.
Mayo Clin Proc Innov Qual Outcomes ; 5(6): 1118-1127, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34877476

RESUMEN

OBJECTIVE: To analyze outcomes of patients with ST-segment elevation myocardial infarction (STEMI) after successful primary percutaneous coronary intervention (PCI) triaged to the cardiac intensive care unit (CICU) vs a general telemetry unit by a Zwolle risk score-based algorithm. METHODS: We introduced a quality improvement protocol in 2014 encouraging admission of STEMI patients with Zwolle score of 3 or less to general telemetry units unless they were hemodynamically unstable. We subsequently conducted a retrospective single-center cohort study of consecutive STEMI patients who had undergone primary PCI from January 1, 2014, to December 31, 2018. Outcomes studied include immediate complications, need for urgent unplanned intervention, need for CICU care, length of hospitalization, and survival. RESULTS: We identified 547 patients, 406 with a Zwolle score of 3 or less. Of these, 192 (47.3%) were admitted to general telemetry and 214 (52.7%) to the CICU. Reasons for CICU admission included persistent chest pain, late presentation, and procedural complications. The average hospital length of stay was 2.1±1.4 days for non-CICU patients and 3.3±2.8 days for low-risk CICU patients (P<.001). Two patients initially admitted to general telemetry required transfer to the CICU. There were 26 patients who required unplanned cardiovascular intervention within 30 days, 5 from the general telemetry unit; 540 patients survived to discharge. One in-hospital death occurred among those initially triaged to the general telemetry unit, and this was due to a noncardiac cause. CONCLUSION: A Zwolle score-based algorithm can be used to safely triage post-PCI STEMI patients to a general telemetry unit.

11.
J Am Heart Assoc ; 10(10): e020033, 2021 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-33960210

RESUMEN

Background The temporal incidence of high-grade atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR) is uncertain. As a result, periprocedural monitoring and pacing strategies remain controversial. This study aimed to describe the temporal incidence of initial episode of HAVB stratified by pre- and post-TAVR conduction and identify predictors of delayed events. Methods and Results Consecutive patients undergoing TAVR at a single center between February 2012 and June 2019 were retrospectively assessed for HAVB within 30 days. Patients with prior aortic valve replacement, permanent pacemaker (PPM), or conversion to surgical replacement were excluded. Multivariable logistic regression was performed to assess predictors of delayed HAVB (initial event >24 hours post-TAVR). A total of 953 patients were included in this study. HAVB occurred in 153 (16.1%). After exclusion of those with prophylactic PPM placed post-TAVR, the incidence of delayed HAVB was 33/882 (3.7%). Variables independently associated with delayed HAVB included baseline first-degree atrioventricular block or right bundle-branch block, self-expanding valve, and new left bundle-branch block. Forty patients had intraprocedural transient HAVB, including 16 who developed HAVB recurrence and 6 who had PPM implantation without recurrence. PPM was placed for HAVB in 130 (13.6%) (self-expanding valve, 23.7% versus balloon-expandable valve, 11.9%; P<0.001). Eight (0.8%) patients died by 30 days, including 1 unexplained without PPM present. Conclusions Delayed HAVB occurs with higher frequency in patients with baseline first-degree atrioventricular block or right bundle-branch block, new left bundle-branch block, and self-expanding valve. These findings provide insight into optimal monitoring and pacing strategies based on periprocedural ECG findings.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bloqueo Atrioventricular/epidemiología , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Minnesota/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Gestión de Riesgos
12.
J Med Syst ; 45(4): 53, 2021 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-33704592

RESUMEN

The Transcatheter Aortic Valve Replacement (TAVR) procedure requires an initial consultation and a subsequent procedure by an interventionalist (IC) and surgeon. The IC-surgeon pair coordination is extremely challenging, especially at Mayo Clinic due to provider time commitments distributed across practice, research, and education activities. Current practice aims to establish the coordination manually, resulting in a scheduling process that is cumbersome and time consuming for the schedulers. We develop an algorithm for pairing ICs and surgeons that minimizes the lead time (days elapsed between the clinic consult and procedure). As compared to current practice, this algorithm is able to reduce average lead time by 59% and increase possible IC-surgeon pairs by 7%. The proposed algorithm is shown to be flexible enough to incorporate practice variations such as lead time upper bound and two procedure days for a single consult day. Algorithm alternatives are also presented for practices who may find the proposed algorithm infeasible for their practice.


Asunto(s)
Estenosis de la Válvula Aórtica , Cirujanos , Reemplazo de la Válvula Aórtica Transcatéter , Algoritmos , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Resultado del Tratamiento
13.
ESC Heart Fail ; 8(3): 2025-2035, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33704924

RESUMEN

AIMS: There are limited contemporary data on the use of initial fibrinolysis in ST-segment elevation myocardial infarction cardiogenic shock (STEMI-CS). This study sought to compare the outcomes of STEMI-CS receiving initial fibrinolysis vs. primary percutaneous coronary intervention (PPCI). METHODS: Using the National (Nationwide) Inpatient Sample from 2009 to 2017, a comparative effectiveness study of adult (>18 years) STEMI-CS admissions receiving pre-hospital/in-hospital fibrinolysis were compared with those receiving PPCI. Admissions with alternate indications for fibrinolysis and STEMI-CS managed medically or with surgical revascularization (without fibrinolysis) were excluded. Outcomes of interest included in-hospital mortality, development of non-cardiac organ failure, complications, hospital length of stay, hospitalization costs, use of palliative care, and do-not-resuscitate status. RESULTS: During 2009-2017, 5297 and 110 452 admissions received initial fibrinolysis and PPCI, respectively. Compared with those receiving PPCI, the fibrinolysis group was more often non-White, with lower co-morbidity, and admitted on weekends and to small rural hospitals (all P < 0.001). In the fibrinolysis group, 95.3%, 77.4%, and 15.7% received angiography, PCI, and coronary artery bypass grafting, respectively. The fibrinolysis group had higher rates of haemorrhagic complications (13.5% vs. 9.9%; P < 0.001). The fibrinolysis group had comparable all-cause in-hospital mortality [logistic regression analysis: 28.8% vs. 28.5%; propensity-matched analysis: 30.8% vs. 30.3%; adjusted odds ratio 0.97 (95% confidence interval 0.90-1.05); P = 0.50]. The fibrinolysis group had comparable rates of acute organ failure, hospital length of stay, rates of palliative care referrals, do-not-resuscitate status use, and lesser hospitalization costs. CONCLUSIONS: The use of initial fibrinolysis had comparable in-hospital mortality than those receiving PPCI in STEMI-CS in the contemporary era in this large national observational study.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Adulto , Fibrinólisis , Humanos , Infarto del Miocardio con Elevación del ST/complicaciones , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/cirugía , Choque Cardiogénico/epidemiología , Choque Cardiogénico/etiología , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 97(3): E274-E279, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32442332

RESUMEN

OBJECTIVES: The purpose of this study was to explore the feasibility and safety of robotic PCI performed using an off-siteremote-control system in an animal model. BACKGROUND: Access to primary percutaneous coronary intervention (PCI) remains a challenge in acute myocardial infarction management. The combination of telemedicine and robotic PCI allow the potential delivery of primary PCI to remote locations without the delay of transfer. METHODS: This single-center prospective pilot preclinical feasibility study compared robotic PCI with remote PCI on swine across three stages (adjacent room, different floor of the same building, two different buildings). Latency up to 1,000 ms was introduced into the operating environment to simulate decreased network quality (blinded to operator). The primary outcome measures were technical success and acute safety. The secondary outcome measures included lesion wiring time, procedural time and qualitative scoring of the PCI experience by the operator. RESULTS: Across 52 experiments in 15 animals, technical success was 100%. No procedural complications occurred during the study. No significant difference in lesion treatment time was detected between stages (p = .11) and between time per target vessel when latency up to 1,000 ms was introduced (p = .58). Injected delay >250 ms had the greatest impact on procedure perceived lag. Longer procedure time was associated with lower procedure impact score, regardless of injected latency. CONCLUSIONS: Remote robotic PCI was feasible and safe in an animal model. Procedural duration was acceptable and unaffected by network latency. Future studies are needed to determine the safety and feasibility of remote PCI in humans.


Asunto(s)
Intervención Coronaria Percutánea , Procedimientos Quirúrgicos Robotizados , Animales , Estudios de Factibilidad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Porcinos , Factores de Tiempo , Resultado del Tratamiento
15.
EuroIntervention ; 16(15): e1254-e1261, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-31746759

RESUMEN

AIMS: There are limited data on the trends and outcomes of mechanical circulatory support (MCS)-assisted early percutaneous coronary intervention (PCI) in acute myocardial infarction with cardiogenic shock (AMI-CS). In this study, we sought to assess the use, temporal trends, and outcomes of percutaneous MCS-assisted early PCI in AMI-CS. METHODS AND RESULTS: Using the National Inpatient Sample database from 2005-2014, a retrospective cohort of AMI-CS admissions receiving early PCI (hospital day zero) was identified. MCS use was defined as intra-aortic balloon pump (IABP), percutaneous left ventricular assist device (pLVAD) and extracorporeal membrane oxygenation (ECMO) support. Outcomes of interest included in-hospital mortality, resource utilisation, trends and predictors of MCS-assisted PCI. Of the 110,452 admissions, MCS assistance was used in 55%. IABP, pLVAD and ECMO were used in 94.8%, 4.2% and 1%, respectively. During 2009-2014, there was a decrease in MCS-assisted PCI due to a decrease in IABP, despite an increase in pLVAD and ECMO. Younger age, male sex, lower comorbidity, and cardiac arrest independently predicted MCS use. MCS-assisted PCI was predictive of higher in-hospital mortality (31% vs 26%, adjusted odds ratio 1.23 [1.19-1.27]; p<0.001) and greater resource utilisation. IABP-assisted PCI had lower in-hospital mortality and lesser resource utilisation compared to pLVAD/ECMO. CONCLUSIONS: MCS-assisted PCI identified a sicker AMI-CS cohort. There was a decrease in IABP and an increase in pLVAD/ECMO.


Asunto(s)
Corazón Auxiliar , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Contrapulsador Intraaórtico , Masculino , Infarto del Miocardio/epidemiología , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Choque Cardiogénico/epidemiología , Choque Cardiogénico/terapia , Resultado del Tratamiento
16.
Mayo Clin Proc ; 96(1): 174-182, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33168158

RESUMEN

New technologies in medicine, even if they are promising medically, are often expensive and logistically difficult to implement at the hospital level. Transcatheter aortic valve replacement (TAVR) is a model technology that is revolutionary in treating aortic stenosis, but has been plagued with significant challenges with financial sustainability. In this article, a margin analysis at the hospital level was performed using literature data. A TAVR industry analysis was performed using Porter's Five Forces framework. The data indicate that TAVR is more expensive than surgical aortic valve replacement, although the cost of TAVR is declining with the use of an optimized minimalist protocol. The overall industry is growing as its clinical indications expand, and it will likely undergo significant reduction of costs when new valves enter the US market. As such, TAVR is a growing industry, with financial sustainability currently dependent on operational efficiency. A concluding list of specific program interventions is provided to help TAVR programs improve operational efficiency and clinical outcomes, as well as help decide whether to create, expand, or redirect funding for TAVR programs. Importantly, the frameworks used to analyze this rapidly evolving technology can be applied to other new technologies to determine financial sustainability.


Asunto(s)
Economía Hospitalaria/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/economía , Estenosis de la Válvula Aórtica/economía , Estenosis de la Válvula Aórtica/cirugía , Costos de Hospital/estadística & datos numéricos , Humanos , Tiempo de Internación/economía , Tiempo de Internación/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Estados Unidos
17.
Am J Cardiol ; 135: 1-8, 2020 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-32866446

RESUMEN

Limited data are available on characteristics and long-term outcomes of patients with coronary artery bypass grafts (CABG) undergoing primary percutaneous coronary intervention for ST-elevation myocardial infarction (STEMI). Between January 2000 to December 2014, we identified STEMI patients with prior CABG undergoing primary percutaneous coronary intervention from 3 sites. Kaplan-Meier methods to estimate survival and major adverse cardiac events (MACE) were employed and compared to a propensity matched cohort of non-CABG STEMI patients. Independent predictors of outcomes were analyzed with Cox modeling. Of the 3,212 STEMI patients identified, there were 296 (9.2%) CABG STEMI patients, having nearly similar frequencies of culprit graft (47.6%) versus culprit native (52.4%) as the infarct-related artery (IRA). At 10 years, the adjusted survival was 44% in CABG STEMI versus 55% in non-CABG STEMI (HR 1.26; 95%CI 0.86 to 1.87; p = 0.72). Survival free of MACE was lower for CABG STEMI (graft IRA, 37%; native IRA, 46%) as compared to non-CABG STEMI controls (63%) (p = 0.02). Neither CABG history nor IRA (native vs graft) was independently associated with death or MACE in multivariable analysis. Temporal trends showed no significant change in death or MACE rates of CABG STEMI patients over time. In conclusion, long term survival of CABG STEMI patients is not significantly different than matched STEMI patients without prior CABG; however, CABG STEMI patients were at significantly higher risk for MACE events.


Asunto(s)
Puente de Arteria Coronaria , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/cirugía , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Infarto del Miocardio con Elevación del ST/mortalidad , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
18.
PLoS One ; 15(8): e0238046, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32833995

RESUMEN

BACKGROUND: There are limited data on the complications with a percutaneous left ventricular assist device (pLVAD) vs. intra-aortic balloon pump (IABP) in acute myocardial infarction-cardiogenic shock (AMI-CS). OBJECTIVE: To assess the trends, rates and predictors of complications. METHODS: Using a 17-year AMI-CS population from the National Inpatient Sample, AMI-CS admissions receiving pLVAD and IABP support were evaluated for vascular, lower limb amputation, hematologic, neurologic and acute kidney injury (AKI) complications. In-hospital mortality, hospitalization costs and length of stay in pLVAD and IABP cohorts with complications was studied. RESULTS: Of 168,645 admissions, 7,855 (4.7%) receiving pLVAD support. The pLVAD cohort had higher comorbidity, cardiac arrest (36.1% vs. 29.7%) and non-cardiac organ failure (74.7% vs. 56.9%) rates. Complications were higher in pLVAD compared to IABP cohort-overall 69.0% vs. 54.7%; vascular 3.8% vs. 2.1%; lower limb amputation 0.3% vs. 0.3%; hematologic 36.0% vs. 27.7%; neurologic 4.9% vs. 3.5% and AKI 55.4% vs. 39.1% (all p<0.001 except for amputation). Non-White race, higher comorbidity, organ failure, and extracorporeal membrane oxygen use were predictors of complications for both cohorts. The pLVAD cohort with complications had higher in-hospital mortality (45.5% vs. 33.1%; adjusted odds ratio 1.65 [95% confidence interval 1.55-1.75]), shorter duration of hospital stay, and higher hospitalization costs compared to the IABP cohort with complications (all p<0.001). These results were consistent in propensity-matched pairs. CONCLUSIONS: AMI-CS admissions receiving pLVAD had higher rates of complications compared to the IABP, with worse in-hospital outcomes in the cohort with complications.


Asunto(s)
Corazón Auxiliar/efectos adversos , Contrapulsador Intraaórtico/efectos adversos , Infarto del Miocardio/complicaciones , Complicaciones Posoperatorias/etiología , Choque Cardiogénico/complicaciones , Choque Cardiogénico/cirugía , Enfermedad Aguda , Anciano , Femenino , Hospitales/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Choque Cardiogénico/terapia
19.
Mayo Clin Proc ; 95(5): 1015-1039, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32370835

RESUMEN

Artificial intelligence (AI) is a nontechnical, popular term that refers to machine learning of various types but most often to deep neural networks. Cardiology is at the forefront of AI in medicine. For this review, we searched PubMed and MEDLINE databases with no date restriction using search terms related to AI and cardiology. Articles were selected for inclusion on the basis of relevance. We highlight the major achievements in recent years in nearly all areas of cardiology and underscore the mounting evidence suggesting how AI will take center stage in the field. Artificial intelligence requires a close collaboration among computer scientists, clinical investigators, clinicians, and other users in order to identify the most relevant problems to be solved. Best practices in the generation and implementation of AI include the selection of ideal data sources, taking into account common challenges during the interpretation, validation, and generalizability of findings, and addressing safety and ethical concerns before final implementation. The future of AI in cardiology and in medicine in general is bright as the collaboration between investigators and clinicians continues to excel.


Asunto(s)
Inteligencia Artificial/tendencias , Cardiología/métodos , Cardiopatías , Predicción , Cardiopatías/diagnóstico , Cardiopatías/terapia , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...