Resuscitation ; 200: 110259, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38823474

RESUMEN

BACKGROUND: Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends. METHODS: Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation. RESULTS: Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (-0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (-0.7 vs. -2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg). CONCLUSION: Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.


Asunto(s)
Dióxido de Carbono , Reanimación Cardiopulmonar , Paro Cardíaco Extrahospitalario , Humanos , Reanimación Cardiopulmonar/métodos , Reanimación Cardiopulmonar/normas , Masculino , Femenino , Estudios Retrospectivos , Paro Cardíaco Extrahospitalario/terapia , Persona de Mediana Edad , Dióxido de Carbono/análisis , Anciano , Capnografía/métodos , Volumen de Ventilación Pulmonar/fisiología
2.
J Clin Med ; 12(21)2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37959385

RESUMEN

Background: There is growing interest in the quality of manual ventilation during cardiopulmonary resuscitation (CPR), but accurate assessment of ventilation parameters remains a challenge. Waveform capnography is currently the reference for monitoring ventilation rate in intubated patients, but fails to provide information on tidal volumes and inspiration-expiration timing. Moreover, the capnogram is often distorted when chest compressions (CCs) are performed during ventilation compromising its reliability during CPR. Our main purpose was to characterize manual ventilation during CPR and to assess how CCs may impact on ventilation quality. Methods: Retrospective analysis were performed of CPR recordings fromtwo databases of adult patients in cardiac arrest including capnogram, compression depth, and airway flow, pressure and volume signals. Using automated signal processing techniques followed by manual revision, individual ventilations were identified and ventilation parameters were measured. Oscillations on the capnogram plateau during CCs were characterized, and its correlation with compression depth and airway volume was assessed. Finally, we identified events of reversed airflow caused by CCs and their effect on volume and capnogram waveform. Results: Ventilation rates were higher than the recommended 10 breaths/min in 66.7% of the cases. Variability in ventilation rates correlated with the variability in tidal volumes and other ventilatory parameters. Oscillations caused by CCs on capnograms were of high amplitude (median above 74%) and were associated with low pseudo-volumes (median 26 mL). Correlation between the amplitude of those oscillations with either the CCs depth or the generated passive volumes was low, with correlation coefficients of -0.24 and 0.40, respectively. During inspiration and expiration, reversed airflow events caused opposed movement of gases in 80% of ventilations. Conclusions: Our study confirmed lack of adherence between measured ventilation rates and the guideline recommendations, and a substantial dispersion in manual ventilation parameters during CPR. Oscillations on the capnogram plateau caused by CCs did not correlate with compression depth or associated small tidal volumes. CCs caused reversed flow during inspiration, expiration and in the interval between ventilations, sufficient to generate volume changes and causing oscillations on capnogram. Further research is warranted to assess the impact of these findings on ventilation quality during CPR.

3.
Comput Methods Programs Biomed ; 242: 107847, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37852146

RESUMEN

AIM: The purpose of this study was to develop a simple viscoelastic model to characterize the mechanical properties of chests during manual chest compressions in pre-hospital cardiopulmonary resuscitation (CPR). METHODS: Force and acceleration signals were extracted from CPR monitors used during pre-hospital resuscitation attempts on adult patients. Individual chest compressions were identified and segmented from the chest displacement computed using the force and acceleration. Each compression-recoil cycle was characterized by its elastic coefficient k (a measure of stiffness) and its compression and recoil damping coefficients, dc and dr, respectively (measures of viscosity). We compared the estimated and the calculated chest displacement to assess the goodness of fit of the model. We characterized the chest of patients at the beginning of CPR in relation to sex and age, and their variation as CPR progressed. RESULTS: A total of 1,156,608 chest compressions from 615 patients were analysed. Mean (95% CI) coefficient of determination R2 for the viscoelastic model was 97.9% (97.8-98.1). At the beginning of CPR, k was 104.9 N⋅cm-1 (102.0-107.8), dc was 2.868 N⋅s⋅cm-1 (2.751-2.984) and dr was 4.889 N⋅s⋅cm-1 (4.648-5.129). Damping during recoil was significantly higher than during compression. Stiffness was lower in women than in men. There were no differences in damping coefficients with sex but a higher dr with increasing age. All model coefficients decreased with compression count, with an overall decrease after 3,000 chest compressions of 34.6%, 48.8% and 37.2%, respectively. CONCLUSION: The model accurately described adult chest mechanical properties during CPR, highlighting differences between compression and recoil, sex and age, and a progressive reduction in chest stiffness and viscosity along resuscitation. Our findings may merit further investigation into whether patient-tailored and time-sensitive chest compression technique may be appropriate.


Asunto(s)
Reanimación Cardiopulmonar , Masculino , Humanos , Adulto , Femenino , Tórax , Presión , Hospitales
4.
Resuscitation ; 179: 225-232, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35835250

RESUMEN

AIM: Characterise how changes in chest compression depth and rate affect variations in end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) in out-of-hospital cardiac arrest (OHCA). METHODS: Retrospective analysis of adult OHCA monitor-defibrillator recordings having concurrent capnogram, compression depth, transthoracic impedance and ECG, and with atleast 1,000 compressions. Within each patient, during no spontaneous circulation, nearby segments with changes in chest compression depth and rate were identified. Average ETCO2 within each segment was standardised to compensate for ventilation rate variability. Contributions of relative variations in depth and rate to relative variations in standardised ETCO2 were characterised using linear and non-linear models. Normalisation between paired segments removed intra and inter-patient variation and made coefficients of the model independent of the scale of measurement and therefore directly comparable. RESULTS: A total of 394 pairs of segments from 221 patients were analysed (33% female, median (IQR) age 66 (55-74) years). Chest compression depth and rate were 50.4 (43.2-57.0)mm and 111.1 (106.5-116.1)compressions per minute. ETCO2 before and after standardization was 32.1 (23.0-41.4)mmHg and 28.5 (19.4-38.7)mmHg. Linear model coefficient of determination was 0.89. Variation in compression depth mainly explained ETCO2 variation (coefficient 0.95, 95% confidence interval (CI): 0.93-0.98) while changes in compression rate did not (coefficient 0.04, 95% CI: 0.01-0.07). Non-linear trend analysis confirmed the results. CONCLUSION: This study quantified the relative importance of chest compression characteristics in terms of their impact on CO2 production during CPR. With ventilation rate standardised, variation in chest compression depth explained variations in ETCO2 better than variation in chest compression rate.


Asunto(s)
Reanimación Cardiopulmonar , Paro Cardíaco Extrahospitalario , Adulto , Anciano , Dióxido de Carbono/análisis , Reanimación Cardiopulmonar/métodos , Femenino , Hospitales , Humanos , Masculino , Paro Cardíaco Extrahospitalario/terapia , Estudios Retrospectivos