Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
F1000Res ; 10: 422, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34527216

RESUMEN

A simple optical pH sensor using the active compound anthocyanin (ACN), derived Ruellia tuberosa L. flower immobilized in a pectin membrane matrix, was been fabricated and employed to monitor the freshness of tilapia fish at room temperature and 4 oC storage. The optimum pectin weight and ACN concentrations were 0.1% and 0.025 mg/L. The sensor showed good sensitivity at 0.03 M phosphate buffer solution. The sensor's reproducibility was evaluated using 10 replicate sensors where a standard deviation of 0.045 or relative standard deviation of 9.15 was achieved. The sensor displayed an excellent response after 10 minutes of exposure, possessing a response stability for 10 consecutive days. The decrease in pH value of the Tilapia fish from 7.3 to 5 was observed in a 48 hour test, which can be used as the parameter when monitoring fish freshness.


Asunto(s)
Acanthaceae , Antocianinas , Animales , Concentración de Iones de Hidrógeno , Pectinas , Reproducibilidad de los Resultados
2.
Biosensors (Basel) ; 9(4)2019 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-31766218

RESUMEN

A novel and simple optical biosensor to detect triglycerides (TGs) has been successfully constructed by using pectin hydrogel membrane as the indicator pH and chromoionophore ETH 5294 (CI), with lipase as the catalyst. The enzymatic working system against TGs releasing H+ ions will affect the color absorbance of CI. The characterization results show that a TG biosensor has the optimum condition and sensitivity at the phosphate buffer concentration of 50 mM, pH 7, and enzyme loading of 60 µg. The biosensor works at the tripalmitin (TP) concentration range of 100-400 mg/dL. With the sensitivity of 0.001 (∆A/(mg/dL)), the biosensor response reaches stability after five minutes, and the limit of detection (LOD) of the TG optical biosensor is 15 mg/dL. Relative standard deviation (RSD) in a reproducibility test was 2.5%, with a 15-day lifespan.


Asunto(s)
Técnicas Biosensibles , Enzimas Inmovilizadas/química , Hidrogeles/química , Lipasa/química , Pectinas/química , Triglicéridos/química , Enzimas Inmovilizadas/metabolismo , Hidrogeles/metabolismo , Lipasa/metabolismo , Imagen Óptica , Pectinas/metabolismo , Triglicéridos/metabolismo
3.
Food Chem ; 269: 503-510, 2018 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-30100466

RESUMEN

The presence of carcinogens in food is a major food safety concern. A nanocomposite-based electrochemical DNA biosensor was constructed for potential carcinogen detection in food samples by immobilizing amine terminated single stranded DNA onto silica nanospheres deposited onto a screen-printed electrode modified using gold nanoparticles. The effect of three different DNA sequences: 15-base guanine, 24-base guanine and 24-base adenine-thymine rich DNA on carcinogen (formaldehyde and acrylamide) detection was evaluated. The competitive binding of the DNA with the carcinogen and electroactive indicator, Methylene blue (MB) was measured using differential pulse voltammetry. Optimization studies were conducted for MB concentration and accumulation time, DNA concentration, buffer concentration, pH and ionic strength. Overall, the 24-base guanine rich DNA yielded the best results with a detection limit of 0.0001 ppm, linear range between 0.0001 ppm and 0.1 ppm and reproducibility below 5% R.S.D. Finally, the results obtained using the biosensor were validated using Ames test.


Asunto(s)
Técnicas Biosensibles/métodos , Carcinógenos/aislamiento & purificación , ADN/análisis , Análisis de los Alimentos/métodos , Oro , Nanopartículas del Metal , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...