Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Total Environ ; 900: 165744, 2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-37487894

RESUMEN

Source apportionment (SA) for indoor air pollution is challenging due to the multiplicity and high variability of indoor sources, the complex physical and chemical processes that act as primary sources, sinks and sources of precursors that lead to secondary formation, and the interconnection with the outdoor environment. While the major indoor sources have been recognized, there is still a need for understanding the contribution of indoor versus outdoor-generated pollutants penetrating indoors, and how SA is influenced by the complex processes that occur in indoor environments. This paper reviews our current understanding of SA, through reviewing information on the SA techniques used, the targeted pollutants that have been studied to date, and their source apportionment, along with limitations or knowledge gaps in this research field. The majority (78 %) of SA studies to date focused on PM chemical composition/size distribution, with fewer studies covering organic compounds such as ketones, carbonyls and aldehydes. Regarding the SA method used, the majority of studies have used Positive Matrix Factorization (31 %), Principal Component Analysis (26 %) and Chemical Mass Balance (7 %) receptor models. The indoor PM sources identified to date include building materials and furniture emissions, indoor combustion-related sources, cooking-related sources, resuspension, cleaning and consumer products emissions, secondary-generated pollutants indoors and other products and activity-related emissions. The outdoor environment contribution to the measured pollutant indoors varies considerably (<10 %- 90 %) among the studies. Future challenges for this research area include the need for optimization of indoor air quality monitoring and data selection as well as the incorporation of physical and chemical processes in indoor air into source apportionment methodology.

2.
Artículo en Inglés | MEDLINE | ID: mdl-34886269

RESUMEN

Using low-cost portable air quality (AQ) monitoring devices is a growing trend in personal exposure studies, enabling a higher spatio-temporal resolution and identifying acute exposure to high concentrations. Comprehension of the results by participants is not guaranteed in exposure studies. However, information on personal exposure is multiplex, which calls for participant involvement in information design to maximise communication output and comprehension. This study describes and proposes a model of a user-centred design (UCD) approach for preparing a final report for participants involved in a multi-sensor personal exposure monitoring study performed in seven cities within the EU Horizon 2020 ICARUS project. Using a combination of human-centred design (HCD), human-information interaction (HII) and design thinking approaches, we iteratively included participants in the framing and design of the final report. User needs were mapped using a survey (n = 82), and feedback on the draft report was obtained from a focus group (n = 5). User requirements were assessed and validated using a post-campaign survey (n = 31). The UCD research was conducted amongst participants in Ljubljana, Slovenia, and the results report was distributed among the participating cities across Europe. The feedback made it clear that the final report was well-received and helped participants better understand the influence of individual behaviours on personal exposure to air pollution.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Contaminantes Atmosféricos/análisis , Contaminación del Aire/análisis , Ciudades , Exposición a Riesgos Ambientales/análisis , Monitoreo del Ambiente , Europa (Continente) , Humanos
3.
Artículo en Inglés | MEDLINE | ID: mdl-34770131

RESUMEN

Use of a multi-sensor approach can provide citizens with holistic insights into the air quality of their immediate surroundings and their personal exposure to urban stressors. Our work, as part of the ICARUS H2020 project, which included over 600 participants from seven European cities, discusses the data fusion and harmonization of a diverse set of multi-sensor data streams to provide a comprehensive and understandable report for participants. Harmonizing the data streams identified issues with the sensor devices and protocols, such as non-uniform timestamps, data gaps, difficult data retrieval from commercial devices, and coarse activity data logging. Our process of data fusion and harmonization allowed us to automate visualizations and reports, and consequently provide each participant with a detailed individualized report. Results showed that a key solution was to streamline the code and speed up the process, which necessitated certain compromises in visualizing the data. A thought-out process of data fusion and harmonization of a diverse set of multi-sensor data streams considerably improved the quality and quantity of distilled data that a research participant received. Though automation considerably accelerated the production of the reports, manual and structured double checks are strongly recommended.


Asunto(s)
Contaminación del Aire , Ciudades , Humanos , Almacenamiento y Recuperación de la Información
4.
Indoor Air ; 31(2): 426-439, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32966653

RESUMEN

The aim of this study was to explore the association between the building-related occupants' reported health symptoms and the indoor pollutant concentrations in a sample of 148 office rooms, within the framework of the European OFFICAIR research project. A large field campaign was performed in 37 office buildings among eight countries, which included (a) 5-day air sampling of volatile organic compounds (VOCs), aldehydes, ozone, and NO2 (b) collection of information from 1299 participants regarding their personal characteristics and health perception at workplace using online questionnaires. Stepwise and multilevel logistic regressions were applied to investigate associations between health symptoms and pollutant concentrations considering personal characteristics as confounders. Occupants of offices with higher pollutant concentrations were more likely to report health symptoms. Among the studied VOCs, xylenes were associated with general (such as headache and tiredness) and skin symptoms, ethylbenzene with eye irritation and respiratory symptoms, a-pinene with respiratory and heart symptoms, d-limonene with general symptoms, and styrene with skin symptoms. Among aldehydes, formaldehyde was associated with respiratory and general symptoms, acrolein with respiratory symptoms, propionaldehyde with respiratory, general, and heart symptoms, and hexanal with general SBS. Ozone was associated with almost all symptom groups.


Asunto(s)
Contaminación del Aire Interior , Exposición por Inhalación/estadística & datos numéricos , Aldehídos , Autoevaluación Diagnóstica , Monitoreo del Ambiente , Formaldehído , Humanos , Síndrome del Edificio Enfermo , Compuestos Orgánicos Volátiles , Lugar de Trabajo
6.
Indoor Air ; 30(1): 76-87, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31593610

RESUMEN

The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and VOCs in 37 newly built or recently retrofitted office buildings across 8 European countries in summer and winter and (b) the collection of information on building and offices' characteristics using checklists. Linear mixed models for repeated measurements were applied to identify the main factors affecting the measured concentrations of selected indoor air pollutants (IAPs). Several associations between aldehydes and VOCs concentrations and buildings' structural characteristic or occupants' activity patterns were identified. The aldehyde and VOC determinants in office buildings include building and furnishing materials, indoor climate characteristics (room temperature and relative humidity), the use of consumer products (eg, cleaning and personal care products, office equipment), as well as the presence of outdoor sources in the proximity of the buildings (ie, vehicular traffic). Results also showed that determinants of indoor air concentrations varied considerably among different type of pollutants.


Asunto(s)
Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Lugar de Trabajo/estadística & datos numéricos , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/estadística & datos numéricos , Aldehídos/análisis , Europa (Continente) , Modelos Lineales , Compuestos Orgánicos Volátiles/análisis
7.
Sci Total Environ ; 650(Pt 2): 2337-2354, 2019 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-30292125

RESUMEN

This paper aims to identify the chemical fingerprints of potential PM2.5 sources and estimate their contribution to Thessaloniki port-city's air quality. For this scope, Positive Matrix Factorization model was applied on a comprehensive PM2.5 dataset collected over a one-year period, at two sampling sites: the port and the city center. The model indicated six and five (groups of) sources contributing to particle concentration at the two sites, respectively. Traffic and biomass burning (winter months) comprise the major local PM sources for Thessaloniki (their combined contribution can exceed 70%), revealing two of the major control-demanding problems of the city. Shipping and in-port emissions have a non-negligible impact (average contribution to PM2.5: 9-13%) on both primary and secondary particles. Road dust factor presents different profile and contribution at the two sites (19.7% at the port; 7.4% at the city center). The secondary-particle factor represents not only the aerosol transportation over relatively long distances, but also a part of traffic-related pollution (14% at the port; 34% at the city center). The study aims to contribute to the principal role of quantitative information on emission sources (source apportionment) in port-cities for the implementation of the air quality directives and guidelines for public health.

8.
Sci Total Environ ; 587-588: 59-67, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-28228238

RESUMEN

In the frame of the OFFICAIR project, office buildings were investigated across Europe to assess how the office workers are exposed to different particulate matter (PM) characteristics (i.e. PM2.5 mass concentration, particulate oxidative potential (OP) based on ascorbate and reduced glutathione depletion, trace element concentration and total particle number concentration (PNC)) within the buildings. Two offices per building were investigated during the working hours (5 consecutive days; 8h per day) in two campaigns. Differences were observed for all parameters across the office buildings. Our results indicate that the monitoring of the PM2.5 mass concentration in different offices within a building might not reflect the spatial variation of the health relevant PM characteristics such as particulate OP or the concentration of certain trace elements (e.g., Cu, Fe), since larger differences were apparent within a building for these parameters compared to that obtained for the PM2.5 mass concentration in many cases. The temporal variation was larger for almost all PM characteristics (except for the concentration of Mn) than the spatial differences within the office buildings. These findings indicate that repeated or long-term monitoring campaigns are necessary to have information about the temporal variation of the PM characteristics. However, spatial variation in exposure levels within an office building may cause substantial differences in total exposure in the long term. We did not find strong associations between the investigated indoor activities such as printing or windows opening and the PNC values. This might be caused by the large number of factors affecting PNC indoors and outdoors.

9.
Sci Total Environ ; 579: 169-178, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-27866741

RESUMEN

The European project OFFICAIR aimed to broaden the existing knowledge regarding indoor air quality (IAQ) in modern office buildings, i.e., recently built or refurbished buildings. Thirty-seven office buildings participated in the summer campaign (2012), and thirty-five participated in the winter campaign (2012-2013). Four rooms were investigated per building. The target pollutants were twelve volatile organic compounds, seven aldehydes, ozone, nitrogen dioxide and particulate matter with aerodynamic diameter <2.5µm (PM2.5). Compared to other studies in office buildings, the benzene, toluene, ethylbenzene, and xylene concentrations were lower in OFFICAIR buildings, while the α-pinene and d-limonene concentrations were higher, and the aldehyde, nitrogen dioxide and PM2.5 concentrations were of the same order of magnitude. When comparing summer and winter, significantly higher concentrations were measured in summer for formaldehyde and ozone, and in winter for benzene, α-pinene, d-limonene, and nitrogen dioxide. The terpene and 2-ethylhexanol concentrations showed heterogeneity within buildings regardless of the season. Considering the average of the summer and winter concentrations, the acetaldehyde and hexanal concentrations tended to increase by 4-5% on average with every floor level increase, and the nitrogen dioxide concentration tended to decrease by 3% on average with every floor level increase. A preliminary evaluation of IAQ in terms of potential irritative and respiratory health effects was performed. The 5-day median and maximum indoor air concentrations of formaldehyde and ozone did not exceed their respective WHO air quality guidelines, and those of acrolein, α-pinene, and d-limonene were lower than their estimated thresholds for irritative and respiratory effects. PM2.5 indoor concentrations were higher than the 24-h and annual WHO ambient air quality guidelines.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Contaminación del Aire Interior/estadística & datos numéricos , Europa (Continente) , Material Particulado/análisis , Compuestos Orgánicos Volátiles/análisis
10.
Artículo en Inglés | MEDLINE | ID: mdl-27120608

RESUMEN

Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers' comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants' comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 "modern" office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants' comfort. The highest association with occupants' overall comfort was found for "noise", followed by "air quality", "light" and "thermal" satisfaction. Analysis of detailed parameters revealed that "noise inside the buildings" was highly associated with occupants' overall comfort. "Layout of the offices" was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building's location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.


Asunto(s)
Ambiente Controlado , Lugar de Trabajo/psicología , Adulto , Contaminación del Aire Interior , Eficiencia , Emociones , Ambiente , Etnicidad , Europa (Continente) , Femenino , Finlandia , Francia , Grecia , Humanos , Hungría , Italia , Masculino , Persona de Mediana Edad , Países Bajos , Percepción , Satisfacción Personal , Portugal , España , Encuestas y Cuestionarios , Lugar de Trabajo/estadística & datos numéricos
11.
Environ Int ; 92-93: 324-33, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27128717

RESUMEN

In the frame of the OFFICAIR project, indoor and outdoor PM2.5 samples were collected in office buildings across Europe in two sampling campaigns (summer and winter). The ability of the particles to deplete physiologically relevant antioxidants (ascorbic acid (AA), reduced glutathione (GSH)) in a synthetic respiratory tract lining fluid, i.e., oxidative potential (OP), was assessed. Furthermore, the link between particulate OP and the concentration of the PM constituents was investigated. The mean indoor PM2.5 mass concentration values were substantially lower than the related outdoor values with a mean indoor/outdoor PM2.5 mass concentration ratio of 0.62 and 0.61 for the summer and winter campaigns respectively. The OP of PM2.5 varied markedly across Europe with the highest outdoor OP(AA) m(-3) and OP(GSH) m(-3) (% antioxidant depletion/m(3) air) values obtained for Hungary, while PM2.5 collected in Finland exhibited the lowest values. Seasonal variation could be observed for both indoor and outdoor OP(AA) m(-3) and OP(GSH) m(-3) with higher mean values during winter. The indoor/outdoor OP(AA) m(-3) and OP(GSH) m(-3) ratios were less than one with 4 and 17 exceptions out of the 40 cases respectively. These results indicate that indoor air is generally less oxidatively challenging than outdoors. Correlation analysis revealed that trace elements play an important role in determining OP, in particular, the Cu content. Indoor air chemistry might affect OP since weaker correlations were obtained for indoor PM2.5. Our findings also suggest that office workers may be exposed to health relevant PM constituents to a different extent within the same building.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Material Particulado/análisis , Europa (Continente) , Tamaño de la Partícula , Estaciones del Año , Oligoelementos/análisis
12.
Environ Sci Pollut Res Int ; 22(9): 6812-26, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25430014

RESUMEN

The chemical characterization of particulate matter (PM) 2.5 fraction was studied during a 1-year sampling campaign conducted at a site near Thessaloniki's port area. PM2.5 collected samples were chemically analyzed for polycyclic aromatic hydrocarbons, minerals, and trace elements (Pb, Ni, Cu, V, Mn, Cr, Zn, Mg, K, Ti, Fe, Ca, and Al); water-soluble ions (Cl(-), NO3 (-), SO4 (2-), K(+), Na(+), NH4 (+), Mg(2+), Ca(2+)); and organic and elemental carbon. The average annual PM2.5 concentration (66.0 µg/m(3)) was at the highest level compared with other studies reported for the same city but different sampling sites. The average daily sum of the measured concentration of polycyclic aromatic hydrocarbons (PAHs) was 12.76 ng/m(3); this value decreased to 6.73 ng/m(3) for the warm period and reached the value of 19.8 ng/m(3) for the cold period. The average concentration of benzo[a]pyrene during the sampling period was 0.75 ng/m(3), which is below the European Union limit value of 1.0 ng/m(3). The ionic content comprised, on average, 22.6 % of the PM2.5 mass, with sulfate and ammonium being the most abundant species (31 and 26 %, respectively, of measured ions during the whole sampling period). The annual mean concentrations of organic carbon (OC) and elemental carbon (EC) were 10.5 ± 6.3 and 2.3 ± 1.5 µg/m(3), respectively. The OC/EC ratio ranged from 1.6 to 9.9, suggesting that there is a significant influence of residential wood burning for heating as well as ship and vehicle emissions to the sampling area. Finally, the elemental composition of associated PM2.5 was dominated by Ca, Fe, and Al. Although conclusions based only on PM2.5 measurements cannot entirely estimate all harbor sources' contribution, there is evidence to support that port activities affect the city's air quality and vice versa.


Asunto(s)
Contaminantes Atmosféricos/análisis , Material Particulado/análisis , Ciudades , Monitoreo del Ambiente , Grecia , Hidrocarburos Policíclicos Aromáticos/análisis , Emisiones de Vehículos/análisis
13.
Environ Monit Assess ; 167(1-4): 321-31, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19572108

RESUMEN

During the last decades, the air quality of the city of Athens has been quite aggravated. Scientific interest has been focused on health effects caused by both outdoor and indoor air pollution. The purpose of this study was the presentation of results from air quality measurements in two similar typical Athenian apartments in the same suburban area. In addition, smoking contribution is investigated, as it is the main factor which differentiates the two apartments. The results showed that it is the outdoor environment that mainly contributes to the air quality of the non-smokers' house. In the second apartment, PM2.5, PM1, and benzene concentrations were found significantly higher due to smoking activity. In contrast, no clear difference in particulate matter ionic composition between the two areas was observed, although in the smoker's house, ion concentrations were found elevated. This observation amplifies the assumption that in the smoker's apartment, significant outdoor sources' contribution cannot be excluded.


Asunto(s)
Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Material Particulado/análisis , Fumar/efectos adversos , Grecia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...