Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Surg Oncol ; 129(7): 1245-1253, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38470544

RESUMEN

BACKGROUND: Our aim was to perform a comparison of three current microwave ablation (MWA) systems widely used for laparoscopic liver ablations in terms of ablation kinetics and geometry of ablation zones. METHODS: This was a retrospective, institutional review board-approved study comparing Emprint, Emprint HP, and NeuWave systems for laparoscopic liver ablation. Analyses were performed via Mann-Whitney U and χ2 tests. Continuous data are presented as median (interquartile range). RESULTS: For Emprint, Emprint HP, and NeuWave groups, tumor size was 1.16 (0.8), 1.21 (0.7), and 1.27 (0.9) cm (p = 0.54). Ablation time per lesion was 7 (6), 4 (2.8), and 4 (3.3) min (p < 0.0001), yielding similar ablation zone volumes and margins. The time to first ablation bubble was 1 (0.13), 1.5 (0.85), and 0.75 (0.5) min, and total ablation times were 7 (4.4), 4 (2), and 3.5 (2.8) min (p < 0.0001). The roundness index A, B, and transverse were 0.94, 0.98, and 0.79; 0.95, 0.95, and 0.78; and 1.02, 0.95, and 0.96. CONCLUSIONS: Although a saline-cooling system with Emprint system allowed for larger diameter spherical ablation zones to be created, it led to decreased efficiency compared to the CO2-cooled NeuWave system, which exposes the active antenna directly to tissue. Increased power delivered by Emprint HP improved the efficiency of saline-cooled design, as demonstrated by faster ablation times.


Asunto(s)
Laparoscopía , Neoplasias Hepáticas , Microondas , Microondas/uso terapéutico , Humanos , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Estudios Retrospectivos , Laparoscopía/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Técnicas de Ablación/métodos , Técnicas de Ablación/instrumentación , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/patología , Ablación por Radiofrecuencia/métodos
2.
Thyroid ; 34(1): 64-69, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37897089

RESUMEN

Background: The impact of near-infrared autofluorescence (NIRAF) imaging on postthyroidectomy hypocalcemia is controversial. As patients with Graves' disease are at increased risk, our aim was to compare postoperative parathyroid function in these patients undergoing total thyroidectomy (TT) with or without NIRAF imaging. Methods: This was a retrospective "before and after" study, comparing outcomes of patients who underwent TT without or with NIRAF imaging at a single center. Primary outcome was the incidence of temporary hypocalcemia and secondary outcomes, rates of incidental parathyroidectomy on final specimens and permanent hypocalcemia. Analyses were performed using Mann-Whitney U and chi-Square tests. Continuous data are expressed as median (interquartile range). Results: There were 85 patients in NIRAF and 100 patients in non-NIRAF group. Groups were comparable regarding age, gender, body-mass index, and thyroid weight. Number of parathyroid glands identified intraoperatively was 3 in both groups (p = 0.47). Intraoperative parathyroid implantation rate was 16.5% in NIRAF and 6% in non-NIRAF group (p = 0.02). Incidental parathyroidectomy rate on final pathology was 12.9% in NIRAF and 32% in non-NIRAF group (p = 0.002). The rates of temporary (11.7% vs. 16%) and permanent hypocalcemia (2.4% vs. 2%) were similar between the two groups, respectively (p = 0.66). Conclusion: To our knowledge, this is the first comparative study investigating the impact of NIRAF on postoperative parathyroid function after thyroidectomy for Graves' disease. The rate of incidental parathyroidectomy on final pathology was lower with use of NIRAF, without an impact on temporary or permanent hypocalcemia rates compared to conventional technique.


Asunto(s)
Enfermedad de Graves , Hipocalcemia , Humanos , Tiroidectomía/efectos adversos , Tiroidectomía/métodos , Hipocalcemia/etiología , Estudios Retrospectivos , Complicaciones Posoperatorias/etiología , Glándulas Paratiroides/diagnóstico por imagen , Glándulas Paratiroides/cirugía , Paratiroidectomía/métodos , Enfermedad de Graves/diagnóstico por imagen , Enfermedad de Graves/cirugía , Enfermedad de Graves/complicaciones , Imagen Óptica/efectos adversos , Imagen Óptica/métodos
3.
Am J Surg ; 2023 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-37945469

RESUMEN

BACKGROUND: Our aim was to investigate utility of indocyanine green (ICG) and autofluorescence (AF) imaging in detection of small bowel primary and metastatic carcinoids. METHODS: Using Institutional Review Board approval, ICG and AF imaging of small bowel carcinoids was performed. Imaging findings were prospectively recorded in operating room and compared with conventional imaging, surgical exploration and pathologic findings. RESULTS: There were 16 patients with 23 primary small bowel tumors, 27 mesenteric lymph nodes, 36 liver metastases and 2 peritoneal nodules. Carcinoid tumors exhibited brighter AF signals compared to background. AF imaging was superior to both DOTATATE PET and surgeon inspection/palpation in demonstrating small bowel primaries. Utility for metastatic lymph nodes and peritoneal metastases was limited. Superficial liver metastases exhibited brighter fluorescence compared to background on both ICG and AF imaging. CONCLUSIONS: This is the largest study assessing utility of near-infrared fluorescence imaging in detection of small bowel carcinoids. Our results show promise in the utilization fluorescence imaging to detect occult primary tumors and superficial liver metastases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...