Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Med Case Rep ; 17(1): 120, 2023 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-37009863

RESUMEN

BACKGROUND: Several factors increase the risk of right-sided endocarditis. The tricuspid valve is usually involved in right-sided endocarditis cases. Infective endocarditis of the pulmonic valve is rare, and few cases of pulmonic valve endocarditis were reported previously. CASE PRESENTATION: Here we describe a case of a 81-year-old Middle Eastern male patient, admitted to our hospital three times in a period of 2 months for fever and cough. He had Streptococcus oralis bacteremia with vegetation that was on the pulmonic valve. We diagnosed him with pulmonic valve endocarditis, and he was treated successfully with intravenous antibiotics. CONCLUSION: It is important to keep high suspicion for isolated pulmonic valve endocarditis in patients with respiratory symptoms. Adequate dental care is important in patients with risk factors for infective endocarditis.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Válvula Pulmonar , Infecciones Estreptocócicas , Humanos , Masculino , Anciano de 80 o más Años , Streptococcus oralis , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/tratamiento farmacológico , Válvula Tricúspide/diagnóstico por imagen , Infecciones Estreptocócicas/complicaciones , Infecciones Estreptocócicas/diagnóstico , Infecciones Estreptocócicas/tratamiento farmacológico
2.
Blood Press Monit ; 26(3): 237-241, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33661139

RESUMEN

OBJECTIVE: The aim of this study was to determine the accuracy of the PHILIPS DL8760, an oscillometric blood pressure (BP) measuring device designed for self-measurement in the general population according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. PARTICIPANTS AND METHODS: The PHILIPS DL8760 measures BP at the brachial level. The validation was performed in 33 subjects. The mean age of the participants was 55.8 ± 14 years. SBP 146.1 ± 26 mmHg (range: 103-193), DBP was 86.8 ± 17.0 mmHg (range: 47-123), and arm circumference was 28.3 ± 4.0 cm (range: 22-39). RESULTS: The PHILIPS DL8760 fulfilled the criteria of the ESH-IP by passing phases one and two for both SBP measurements and DBP measurements. The device overestimated SBP by 1.5 ± 5.0 mmHg and underestimated DBP by 0.7 ± 3.9 mmHg. CONCLUSION: The PHILIPS DL8760 BP device, with its specially designed cuff covering a broad range of arm circumferences, fulfilled the requirements of the International Protocol Revision 2010.


Asunto(s)
Brazo , Hipertensión , Adulto , Anciano , Presión Sanguínea , Determinación de la Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial , Monitores de Presión Sanguínea , Humanos , Hipertensión/diagnóstico , Persona de Mediana Edad , Oscilometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...