Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Sep Sci ; 46(11): e2200770, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36976154

RESUMEN

The design of an appropriate analytical method for assessing the quality of pharmaceuticals requires a deep understanding of science, and risk evaluation approaches are appreciated. The current study discusses how a related substance method was developed for Nintedanib esylate. The best possible separation between the critical peak pairs was achieved using an X-Select charged surface hybrid Phenyl Hexyl (150 × 4.6) mm, 3.5 µm column. A mixture of water, acetonitrile, and methanol in mobile phase-A (70:20:10) and mobile phase-B (20:70:10), with 0.1% trifluoroacetic acid and 0.05% formic acid in both eluents. The set flow rate, wavelength, and injection volumes were 1.0 ml/min, 285 nm, and 5 µl, respectively, with gradient elution. The method conditions were validated as per regulatory requirements and United States Pharmacopeia general chapter < 1225 >. The correlation coefficient for all impurities from the linearity experiment was found to be > 0.999. The % relative standard deviation from the precision experiments ranged from 0.4 to 3.6. The mean %recovery from the accuracy study ranged from 92.5 to 106.5. Demonstrated the power of the stability-indicating method through degradation studies; the active drug component is more vulnerable to oxidation than other conditions. Final method conditions were further evaluated using a full-factorial design. The robust method conditions were identified using the graphical optimization from the design space.


Asunto(s)
Contaminación de Medicamentos , Indoles , Cromatografía Líquida de Alta Presión/métodos , Estabilidad de Medicamentos , Reproducibilidad de los Resultados
2.
Biomed Chromatogr ; 37(4): e5585, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36692333

RESUMEN

Analytical techniques must be sensitive, specific, and accurate to assess the active pharmaceutical ingredients in pharmaceutical dosage forms. The quality-by-design (QbD) application has proven to be a practical method for magnifying HPLC operations. This article discusses the successfully developed QbD-based stability-indicative LC method for evaluating acetaminophen, caffeine, and aspirin (ASP) in tablet dosage form. To achieve the necessary chromatographic separation, Milli-Q water, methanol, and glacial acetic acid were employed in the following ratios: 63:35:2 (v/v/v) for mobile phase A and 18:80:2 (v/v/v) for mobile phase B. The flow rate, column temperature, and detecting wavelength were 1.0 ml/min, 40°C, and 275 nm, respectively, and an InertSustain C18 analytical column (150 × 4.6 mm, 3 µm) was used. Linearity was between 10.0 and 150.0 µg/ml for ASP and acetaminophen and between 2.6 and 39.0 µg/ml for caffeine. The accuracy findings were more than 97%, and the correlation coefficient for all three components was found to be greater than 0.999. The validated HPLC method yielded reliable and accurate results. ASP was shown to be vulnerable to both acid and alkaline hydrolysis in the forced degradation study. The described method is capable of separating the degradants produced during stress testing and is regarded as stability indicating. The proposed method can be used for a wider range of other formulations with an appropriate diluent selection and sample preparation procedure optimization.


Asunto(s)
Acetaminofén , Cafeína , Acetaminofén/análisis , Cafeína/análisis , Comprimidos/química , Cromatografía Líquida de Alta Presión/métodos , Aspirina/análisis
3.
Sci Pharm ; 80(2): 329-36, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22896820

RESUMEN

An unknown impurity formed during stability sample analysis by a gradient reversed phase ultra-high pressure liquid chromatography (UHPLC) of varenicline tablets at 0.2% level. A simple isocratic preparative method was developed to isolate the unknown impurity with 20 min run time. This unknown impurity was identified and characterized by using spectroscopic techniques. Based on the spectral data, the unknown impurity has been characterized as 4,6,7,8,9,10-hexahydro-1H-6,10-methanopyrazino[2,3-h][3]benzazepine-2,3-dione. The structure of this impurity was also established unambiguously, prepared by isolation and co-injected into UHPLC to confirm the retention time. To the best of our knowledge, this impurity has not been reported elsewhere.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...