2.
Ann Clin Biochem ; 32 ( Pt 5): 498-501, 1995 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-8830626

RESUMEN

The measurement of serum inorganic phosphorus by direct acid/molybdate assay is known to be subject to interference by some serum paraproteins. Serum samples from 45 paraproteinaemic patients were used for the measurement of inorganic phosphorus using a manufacturer's kit reagent and a detergent-modified reagent from the same manufacturer. In addition, the same samples were analysed with both reagents following precipitation of serum protein with trichloroacetic acid. Using the original reagent pseudohyperphosphataemia was found in 27% (12/45) of the samples. The modified reagent was free from interference with no significant difference between results from serum and protein-free supernatants.


Asunto(s)
Paraproteinemias/sangre , Paraproteínas/análisis , Fosfatos/sangre , Juego de Reactivos para Diagnóstico , Proteínas Sanguíneas/análisis , Errores Diagnósticos , Humanos , Inmunoglobulina G/sangre , Espectrofotometría
3.
5.
Ann Clin Biochem ; 27 ( Pt 2): 99-101, 1990 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-2327712

RESUMEN

Reference ranges for serum creatinine, derived from 2110 cases aged between 1 day and 20 years, are presented. Levels fall during the neonatal period and then increase with age in both sexes. Levels fall more rapidly in full term infants than in premature infants and are significantly higher in males than in females aged 15 years and above.


Asunto(s)
Creatinina/sangre , Adolescente , Adulto , Factores de Edad , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Masculino , Valores de Referencia
8.
Clin Chem ; 24(9): 1618-9, 1978 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28861

RESUMEN

We have measured total carbon dioxide in plasma with a new carbon dioxide analyzer, and compared the results with total carbon dioxide data derived from measurements of carbon dioxide tension and pH. The results agree sufficiently well to demonstrate that the new instrument provides a simple, efficient procedure for monitoring the precision and accuracy of pH, carbon dioxide tension, or total carbon dioxide in plasma.


Asunto(s)
Sangre , Dióxido de Carbono/sangre , Concentración de Iones de Hidrógeno , Humanos , Métodos , Presión Parcial , Control de Calidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...