ACS Nano ; 18(17): 11025-11041, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38626916

RESUMEN

ALK-positive NSCLC patients demonstrate initial responses to ALK tyrosine kinase inhibitor (TKI) treatments, but eventually develop resistance, causing rapid tumor relapse and poor survival rates. Growing evidence suggests that the combination of drug and immune therapies greatly improves patient survival; however, due to the low immunogenicity of the tumors, ALK-positive patients do not respond to currently available immunotherapies. Tumor-associated macrophages (TAMs) play a crucial role in facilitating lung cancer growth by suppressing tumoricidal immune activation and absorbing chemotherapeutics. However, they can also be programmed toward a pro-inflammatory tumor suppressive phenotype, which represents a highly active area of therapy development. Iron loading of TAMs can achieve such reprogramming correlating with an improved prognosis in lung cancer patients. We previously showed that superparamagnetic iron oxide nanoparticles containing core-cross-linked polymer micelles (SPION-CCPMs) target macrophages and stimulate pro-inflammatory activation. Here, we show that SPION-CCPMs stimulate TAMs to secrete reactive nitrogen species and cytokines that exert tumoricidal activity. We further show that SPION-CCPMs reshape the immunosuppressive Eml4-Alk lung tumor microenvironment (TME) toward a cytotoxic profile hallmarked by the recruitment of CD8+ T cells, suggesting a multifactorial benefit of SPION-CCPM application. When intratracheally instilled into lung cancer-bearing mice, SPION-CCPMs delay tumor growth and, after first line therapy with a TKI, halt the regrowth of relapsing tumors. These findings identify SPIONs-CCPMs as an adjuvant therapy, which remodels the TME, resulting in a delay in the appearance of resistant tumors.


Asunto(s)
Crizotinib , Neoplasias Pulmonares , Nanopartículas Magnéticas de Óxido de Hierro , Microambiente Tumoral , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/patología , Microambiente Tumoral/efectos de los fármacos , Animales , Nanopartículas Magnéticas de Óxido de Hierro/química , Humanos , Ratones , Crizotinib/farmacología , Crizotinib/química , Antineoplásicos/farmacología , Antineoplásicos/química , Inhibidores de Proteínas Quinasas/farmacología , Inhibidores de Proteínas Quinasas/química , Línea Celular Tumoral , Macrófagos Asociados a Tumores/efectos de los fármacos , Macrófagos Asociados a Tumores/metabolismo , Proliferación Celular/efectos de los fármacos , Femenino
2.
J Dent ; 142: 104859, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38272436

RESUMEN

OBJECTIVE: To investigate the image quality of a low-dose dental imaging protocol in the first clinical photon-counting computed tomography (PCCT) system in comparison to a normal-dose acquisition in a digital volume tomography (DVT) system. MATERIALS AND METHODS: Clinical PCCT systems offer an increased spatial resolution compared to previous generations of clinical systems. Their spatial resolution is in the order of dental DVT systems. Resolution-matched acquisitions of ten porcine jaws were performed in a PCCT (Naeotom Alpha, Siemens Healthineers) and in a DVT (Orthophos XL, Dentsply Sirona). PCCT images were acquired with 90 kV at a dose of 1 mGy CTDI16 cm. DVT used 85 kV at 4 mGy. Image reconstruction was performed using the standard algorithms of each system to a voxel size of 160 × 160 × 200 µm. The dose-normalized contrast-to-noise ratio (CNRD) was measured between dentine and enamel and dentine and bone. Two readers evaluated overall diagnostic quality of images and quality of relevant structures such as root channels and dentine. RESULTS: CNRD is higher in all PCCT acquisitions. CNRD is 37 % higher for the contrast dentine-enamel and 31 % higher for the dentine-bone contrast (p < 0.05). Overall diagnostic image quality was higher for PCCT over DVT (p < 0.02 and p < 0.04 for readers 1 and 2). Quality scores for anatomical structures were higher in PCCT compared to DVT (all p < 0.05). Inter- and intrareader reproducibility were acceptable (all ICC>0.64). CONCLUSIONS: PCCT provides an increased image quality over DVT even at a lower dose level and might enable complex dental imaging protocols in the future. CLINICAL SIGNIFICANCE: The evolution of photon-counting technology and it's optimization will increasingly move dental imaging towards standardized 3D visualizations providing both minimal radiation exposure and high diagnostic accuracy.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada por Rayos X , Animales , Porcinos , Reproducibilidad de los Resultados , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador
3.
Med Phys ; 51(3): 1822-1831, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37650780

RESUMEN

BACKGROUND: Due to technical constraints, dual-source dual-energy CT scans may lack spectral information in the periphery of the patient. PURPOSE: Here, we propose a deep learning-based iterative reconstruction to recover the missing spectral information outside the field of measurement (FOM) of the second source-detector pair. METHODS: In today's Siemens dual-source CT systems, one source-detector pair (referred to as A) typically has a FOM of about 50 cm, while the FOM of the other pair (referred to as B) is limited by technical constraints to a diameter of about 35 cm. As a result, dual-energy applications are currently only available within the small FOM, limiting their use for larger patients. To derive a reconstruction at B's energy for the entire patient cross-section, we propose a deep learning-based iterative reconstruction. Starting with A's reconstruction as initial estimate, it employs a neural network in each iteration to refine the current estimate according to a raw data fidelity measure. Here, the corresponding mapping is trained using simulated chest, abdomen, and pelvis scans based on a data set containing 70 full body CT scans. Finally, the proposed approach is tested on simulated and measured dual-source dual-energy scans and compared against existing reference approaches. RESULTS: For all test cases, the proposed approach was able to provide artifact-free CT reconstructions of B for the entire patient cross-section. Considering simulated data, the remaining error of the reconstructions is between 10 and 17 HU on average, which is about half as low as the reference approaches. A similar performance with an average error of 8 HU could be achieved for real phantom measurements. CONCLUSIONS: The proposed approach is able to recover missing dual-energy information for patients exceeding the small 35 cm FOM of dual-source CT systems. Therefore, it potentially allows to extend dual-energy applications to the entire-patient cross section.


Asunto(s)
Aprendizaje Profundo , Humanos , Tomografía Computarizada por Rayos X , Tórax , Fantasmas de Imagen , Algoritmos , Procesamiento de Imagen Asistido por Computador
4.
Eur Radiol ; 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38133673

RESUMEN

OBJECTIVE: To assess the potential dose reduction achievable with clinical photon-counting CT (PCCT) in ultra-high resolution (UHR) mode compared to acquisitions using the standard resolution detector mode (Std). MATERIALS AND METHODS: With smaller detector pixels, PCCT achieves far higher spatial resolution than energy-integrating (EI) CT systems. The reconstruction of UHR acquisitions to the lower spatial resolution of conventional systems results in an image noise and radiation dose reduction. We quantify this small pixel effect in measurements of semi-anthropomorphic abdominal phantoms of different sizes as well as in a porcine knuckle in the first clinical PCCT system by using the UHR mode (0.2 mm pixel size at isocenter) in comparison to the standard resolution mode (0.4 mm). At different slice thicknesses (0.4 up to 4 mm) and dose levels between 4 and 12 mGy, reconstructions using filtered backprojection were performed to the same target spatial resolution, i.e., same modulation transfer function, using both detector modes. Image noise and the resulting potential dose reduction was quantified as a figure of merit. RESULTS: Images acquired using the UHR mode yield lower noise in comparison to acquisitions using standard pixels at the same resolution and noise level. This holds for sharper convolution kernels at the spatial resolution limit of the standard mode, e.g., up to a factor 3.2 in noise reduction and a resulting potential dose reduction of up to almost 90%. CONCLUSION: Using sharper convolution kernels, UHR acquisitions allow for a significant dose reduction compared to acquisitions using the standard detector mode. CLINICAL RELEVANCE: Acquisitions should always be performed using the ultra-high resolution detector mode, if possible, to benefit from the intrinsic noise and dose reduction. KEY POINTS: • Ionizing radiation used in computed tomography examinations is a concern to public health. • The ultra-high resolution of novel photon-counting systems can be invested towards a noise and dose reduction if only a spatial resolution below the resolution limit of the detector is desired. • Acquisitions should always be performed in ultra-high resolution mode, if possible, to benefit from an intrinsic dose reduction.

5.
Phys Med Biol ; 68(13)2023 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-37267991

RESUMEN

Objectives.To characterize for the first timein vivoa novel bismuth-based nanoparticular contrast agent developed for preclinical applications. Then, to design and testin vivoa multi-contrast protocol for functional cardiac imaging using the new bismuth nanoparticles and a well-established iodine-based contrast agent.Approach.A micro-computed tomography scanner was assembled and equipped with a photon-counting detector. Five mice were administered with the bismuth-based contrast agent and systematically scanned over 5 h to quantify the contrast enhancement in relevant organs of interest. Subsequently, the multi-contrast agent protocol was tested on three mice. Material decomposition was performed on the acquired spectral data to quantify the concentration of bismuth and iodine in multiple structures, e.g. the myocardium and vasculature.Main results.In the vasculature, the bismuth agent provides a peak enhancement of 1100 HU and a half-life of about 260 min. After the injection, it accumulates in the liver, spleen and intestinal wall reaching a CT value of 440 HU about 5 h post injection. Phantom measurements showed that the bismuth provides more contrast enhancement than iodine for a variety of tube voltages. The multi-contrast protocol for cardiac imaging successfully allowed the simultaneous decomposition of the vasculature, the brown adipose tissue and the myocardium.Significance.The new bismuth-based contrast agent was proven to have a long circulation time suitable for preclinical applications and to provide more contrast than iodine agents. The proposed multi-contrast protocol resulted in a new tool for cardiac functional imaging. Furthermore, thanks to the contrast enhancement provided in the intestinal wall, the novel contrast agent may be used to develop further multi contrast agent protocols for abdominal and oncological imaging.


Asunto(s)
Yodo , Ratones , Animales , Microtomografía por Rayos X/métodos , Medios de Contraste , Bismuto , Abdomen , Fantasmas de Imagen , Fotones
6.
Radiologie (Heidelb) ; 63(7): 507-512, 2023 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-37069237

RESUMEN

BACKGROUND: The introduction of energy-selective photon-counting detectors into clinical practice represents the next milestone in computed tomography (CT). In addition to significantly higher resolution, these detectors allow the implicit acquisition of dual or multispectral data in a single measurement through the use of typically freely selectable thresholds. This capability reignited the interest in new contrast agents based on heavy elements, so-called high­z elements, for clinical CT. OBJECTIVE: The present article aims to investigate the potential suitability of different chemical elements as contrast agents and to discuss possible clinical applications, for example, K­edge imaging or simultaneous application of different contrast agents. CONCLUSION: First preclinical experiments as well as experiments in large animals could demonstrate potential advantages of contrast agents based on heavy elements. For example, such contrast agents promise a significant increase in image contrast compared to conventional iodine-based agents.


Asunto(s)
Medios de Contraste , Yodo , Animales , Tomografía Computarizada por Rayos X/métodos , Fotones , Fantasmas de Imagen
7.
Z Med Phys ; 33(2): 155-167, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35868888

RESUMEN

X-ray computed tomography (CT) is a cardinal tool in clinical practice. It provides cross-sectional images within seconds. The recent introduction of clinical photon-counting CT allowed for an increase in spatial resolution by more than a factor of two resulting in a pixel size in the center of rotation of about 150 µm. This level of spatial resolution is in the order of dedicated preclinical micro-CT systems. However so far, the need for different dedicated clinical and preclinical systems often hinders the rapid translation of early research results to applications in men. This drawback might be overcome by ultra-high resolution (UHR) clinical photon-counting CT unifying preclinical and clinical research capabilities in a single machine. Herein, the prototype of a clinical UHR PCD CT (SOMATOM CounT, Siemens Healthineers, Forchheim, Germany) was used. The system comprises a conventional energy-integrating detector (EID) and a novel photon-counting detector (PCD). While the EID provides a pixel size of 0.6 mm in the centre of rotation, the PCD provides a pixel size of 0.25 mm. Additionally, it provides a quantification of photon energies by sorting them into up to four distinct energy bins. This acquisition of multi-energy data allows for a multitude of applications, e.g. pseudo-monochromatic imaging. In particular, we examine the relation between spatial resolution, image noise and administered radiation dose for a multitude of use-cases. These cases include ultra-high resolution and multi-energy acquisitions of mice administered with a prototype bismuth-based contrast agent (nanoPET Pharma, Berlin, Germany) as well as larger animals and actual patients. The clinical EID provides a spatial resolution of about 9 lp/cm (modulation transfer function at 10%, MTF10%) while UHR allows for the acquisition of images with up to 16 lp/cm allowing for the visualization of all relevant anatomical structures in preclinical and clinical specimen. The spectral capabilities of the system enable a variety of applications previously not available in preclinical research such as pseudo-monochromatic images. Clinical ultra-high resolution photon-counting CT has the potential to unify preclinical and clinical research on a single system enabling versatile imaging of specimens and individuals ranging from mice to man.


Asunto(s)
Tomografía Computarizada por Rayos X , Investigación Biomédica Traslacional , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Tomógrafos Computarizados por Rayos X , Medios de Contraste , Fotones
8.
Eur Radiol ; 33(2): 803-811, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35986773

RESUMEN

OBJECTIVES: Photon-counting detector computed tomography (PCD-CT) is a promising new technique for CT imaging. The aim of the present study was the in vitro comparison of coil-related artifacts in PCD-CT and conventional energy-integrating detector CT (EID-CT) using a comparable standard brain imaging protocol before and after metal artifact reduction (MAR). METHODS: A nidus-shaped rubber latex, resembling an aneurysm of the cerebral arteries, was filled with neurovascular platinum coils and inserted into a brain imaging phantom. Image acquisition and reconstruction were repeatedly performed for PCD-CT and EID-CT (n = 10, respectively) using a standard brain imaging protocol. Moreover, linear interpolation MAR was performed for PCD-CT and EID-CT images. The degree of artifacts was analyzed quantitatively (standard deviation in a donut-shaped region of interest) and qualitatively (5-point scale analysis). RESULTS: Quantitative and qualitative analysis demonstrated a lower degree of metal artifacts in the EID-CT images compared to the total-energy PCD-CT images (e.g., 82.99 ± 7.89 Hounsfield units (HU) versus 90.35 ± 6.28 HU; p < 0.001) with no qualitative difference between the high-energy bin PCD-CT images and the EID-CT images (4.18 ± 0.37 and 3.70 ± 0.64; p = 0.575). After MAR, artifacts were more profoundly reduced in the PCD-CT images compared to the EID-CT images in both analyses (e.g., 2.35 ± 0.43 and 3.18 ± 0.34; p < 0.001). CONCLUSION: PCD-CT in combination with MAR have the potential to provide an improved option for reduction of coil-related artifacts in cerebral imaging in this in vitro study. KEY POINTS: • Photon-counting detector CT produces more artifacts compared to energy-integrating detector CT without metal artifact reduction in cerebral in vitro imaging after neurovascular coil-embolization. • Spectral information of PCD-CT provides the potential for new post-processing techniques, since the coil-related artifacts were lower in PCD-CT images compared to EID-CT images after linear interpolation metal artifact reduction in this in vitro study.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Encéfalo/diagnóstico por imagen , Fantasmas de Imagen , Fotones , Neuroimagen
9.
Nat Commun ; 13(1): 4557, 2022 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-35931677

RESUMEN

The high plasticity of lung epithelial cells, has for many years, confounded the correct identification of the cell-of-origin of lung adenocarcinoma (LUAD), one of the deadliest malignancies worldwide. Here, we employ lineage-tracing mouse models to investigate the cell of origin of Eml4-Alk LUAD, and show that Club and Alveolar type 2 (AT2) cells give rise to tumours. We focus on Club cell originated tumours and find that Club cells experience an epigenetic switch by which they lose their lineage fidelity and gain an AT2-like phenotype after oncogenic transformation. Single-cell transcriptomic analyses identified two trajectories of Club cell evolution which are similar to the ones used during lung regeneration, suggesting that lung epithelial cells leverage on their plasticity and intrinsic regeneration mechanisms to give rise to a tumour. Together, this study highlights the role of Club cells in LUAD initiation, identifies the mechanism of Club cell lineage infidelity, confirms the presence of these features in human tumours, and unveils key mechanisms conferring LUAD heterogeneity.


Asunto(s)
Adenocarcinoma del Pulmón , Neoplasias Pulmonares , Adenocarcinoma del Pulmón/genética , Adenocarcinoma del Pulmón/patología , Animales , Diferenciación Celular/genética , Transformación Celular Neoplásica/patología , Células Epiteliales/patología , Humanos , Pulmón/patología , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Ratones
10.
Sci Rep ; 12(1): 7125, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-35504943

RESUMEN

Clinical photon-counting CT (PCCT) offers a spatial resolution of about 200 µm and might allow for acquisitions close to conventional dental CBCTs. In this study, the capabilities of this new system in comparison to dental CBCTs shall be evaluated. All 8 apical osteolysis identified in CBCT were identified by both readers in all three PCCT scan protocols. Mean visibility scores showed statistical significant differences for root canals(p = 0.0001), periodontal space(p = 0.0090), cortical(p = 0.0003) and spongious bone(p = 0.0293) in favor of high and medium dose PCCT acquisitions. Overall, both devices showed excellent image quality of all structures assessed. Interrater-agreement showed high values for all protocols in all structures. Bland-Altman plots revealed a high concordance of both modalities with the reference measurements. In vitro, ultra-high resolution PCCT can reliably identify different diagnostic entities and structures relevant for dental diagnostics similar to conventional dental CBCT with similar radiation dose. Acquisitions of five cadaveric heads were performed in an experimental CT-system containing an ultra-high resolution PC detector (0.25 mm pixel size in isocenter) as well as in a dental CBCT scanner. Acquisitions were performed using dose levels of 8.5 mGy, 38.0 mGy and 66.5 mGy (CTDI16cm) in case of PCCT and of 8.94 mGy (CTDI16cm) in case of CBCT. The quality of delineation of hard tissues, root-canals, periodontal-space as well as apical osteolysis was assessed by two readers. Mean visibility scores and interrater-agreement (overall agreement (%)) were calculated. Vertical bone loss (bl) and thickness (bt) of the buccal bone lamina of 15 lower incisors were measured and compared to reference measurements by ore microscopy and clinical probing.


Asunto(s)
Osteólisis , Humanos , Incisivo , Cintigrafía , Tomografía Computarizada por Rayos X/métodos
11.
Z Med Phys ; 32(4): 403-416, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35597742

RESUMEN

Photon-counting (PC) detectors for clinical computed tomography (CT) may offer improved imaging capabilities compared to conventional energy-integrating (EI) detectors, e.g. superior spatial resolution and detective efficiency. We here investigate if PCCT can reduce the administered dose in examinations aimed at quantifying trabecular bone microstructure. Five human vertebral bodies were scanned three times in an abdomen phantom (QRM, Germany) using an experimental dual-source CT (Somatom CounT, Siemens Healthineers, Germany) housing an EI detector (0.60 mm pixel size at the iso-center) and a PC detector (0.25 mm pixel size). A tube voltage of 120 kV was used. Tube current-time product for EICT was 355 mAs (23.8 mGy CTDI32 cm). Dose-matched UHR-PCCT (UHRdm, 23.8 mGy) and noise-matched acquisitions (UHRnm, 10.5 mGy) were performed and reconstructed to a voxel size of 0.156 mm using a sharp kernel. Measurements of bone mineral density (BMD) and trabecular separation (Tb.Sp) and Tb.Sp percentiles reflecting the different scales of the trabecular interspacing were performed and compared to a gold-standard measurement using a peripheral CT device (XtremeCT, SCANCO Medical, Switzerland) with an isotropic voxel size of 0.082 mm and 6.6 mGy CTDI10 cm. The image noise was quantified and the relative error with respect to the gold-standard along with the agreement between CT protocols using Lin's concordance correlation coefficient (rCCC) were calculated. The Mean ±â€¯StdDev of the measured image noise levels in EICT was 109.6 ±â€¯3.9 HU. UHRdm acquisitions (same dose as EICT) showed a significantly lower noise level of 78.6 ±â€¯4.6 HU (p = 0.0122). UHRnm (44% dose of EICT) showed a noise level of 115.8 ±â€¯3.7 HU, very similar to EICT at the same spatial resolution. For BMD the overall Mean ±â€¯StdDev for EI, UHRdm and UHRnm were 114.8 ±â€¯28.6 mgHA/cm3, 121.6 ±â€¯28.8 mgHA/cm3 and 121.5 ±â€¯28.6 mgHA/cm3, respectively, compared to 123.1 ±â€¯25.5 mgHA/cm3 for XtremeCT. For Tb.Sp these values were 1.86 ±â€¯0.54 mm, 1.80 ±â€¯0.56 mm and 1.84 ±â€¯0.52 mm, respectively, compared to 1.66 ±â€¯0.48 mm for XtremeCT. The ranking of the vertebrae with regard to Tb.Sp data was maintained throughout all Tb.Sp percentiles and among the CT protocols and the gold-standard. The agreement between protocols was very good for all comparisons: UHRnm vs. EICT (BMD rCCC = 0.97; Tb.Sp rCCC = 0.998), UHRnm vs. UHRdm (BMD rCCC = 0.998; Tb.Sp rCCC = 0.993) and UHRdm vs. EICT (BMD rCCC = 0.97; Tb.Sp rCCC = 0.991). Consequently, the relative RMS-errors from linear regressions against the gold-standard for EICT, UHRdm and UHRnm were very similar for BMD (7.1%, 5.2% and 5.4%) and for Tb.Sp (3.3%, 3.3% and 2.9%), with a much lower radiation dose for UHRnm. Short-term reproducibility for BMD measurements was similar and below 0.2% for all protocols, but for Tb.Sp showed better results for UHR (about 1/3 of the level for EICT). In conclusion, CT with UHR-PC detectors demonstrated lower image noise and better reproducibility for assessments of bone microstructure at similar dose levels. For UHRnm, radiation exposure levels could be reduced by 56% without deterioration of performance levels in the assessment of bone mineral density and bone microstructure.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Humanos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Abdomen
12.
Med Phys ; 49(7): 4566-4584, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35390181

RESUMEN

BACKGROUND: The image quality of cone beam CT (CBCT) scans severely suffers from scattered radiation if no countermeasures are taken. Scatter artifacts may induce cupping and streak artifacts and lead to a reduced image contrast and wrong CT values of the reconstructed volumes. Established software-based approaches for a correction of scattered radiation typically rely on prior knowledge of the CT system, scan parameters, the scanned object, or all of the aforementioned. PURPOSE: This study proposes a simple and effective postprocessing software-based correction method of scatter artifacts in CBCT scans without specific prior knowledge. METHODS: We propose the empirical scatter correction (ESC), which generates scatter-like basis images from each projection image by convolution operations. A linear combination of these basis images is subtracted from the original projection image. The logarithm is taken and an FDK reconstruction is performed. The coefficients needed for the linear combination are determined automatically by a downhill simplex algorithm such that the resulting reconstructed images show no scatter artifacts. We demonstrate the potential of ESC by correcting simulated volumes with Monte Carlo scatter artifacts, a head phantom scan performed on our table-top CBCT, and a pelvis scan from a Varian Edge CBCT scanner. RESULTS: ESC is able to improve the image quality of CBCT scans, which is shown on the basis of our simulations and on measured data. For a simulated head CT, the CT value difference to the scatter-free reference image was as low as -6 HU after using ESC, whereas the uncorrected data deviated by more than -200 HU from the reference data. Simulations of thorax and abdomen CT scans show that although scatter artifacts are not fully removed, anatomical features which were hard to discover prior to the correction become clearly visible and better segmentable with ESC. Similar results are obtained in the phantom measurement, where a comparison to a slit scan of our head phantom shows only small differences. The CT values in soft tissue are improved in this measurement, as well. In soft tissue areas with severe scatter artifacts, the CT values agree well with those of the slit scan (difference to slit scan: 35 HU corrected and -289 HU uncorrected). Scatter artifacts in measured patient data can also be reduced using the proposed ESC. The results are comparable to those achieved with designated correction algorithms installed on the Varian Edge CBCT system. CONCLUSIONS: ESC allows to reduce artifacts caused by patient scatter solely based on the projection data.


Asunto(s)
Artefactos , Tomografía Computarizada de Haz Cónico Espiral , Algoritmos , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Dispersión de Radiación
13.
Med Phys ; 49(7): 4391-4403, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35421263

RESUMEN

PURPOSE: Modern CT scanners use automatic exposure control (AEC) techniques, such as tube current modulation (TCM), to reduce dose delivered to patients while maintaining image quality. In contrast to conventional approaches that minimize the tube current time product of the CT scan, referred to as mAsTCM in the following, we herein propose a new method referred to as riskTCM, which aims at reducing the radiation risk to the patient by taking into account the specific radiation risk of every dose-sensitive organ. METHODS: For current mAsTCM implementations, the mAs product is used as a surrogate for the patient dose. Thus, they do not take into account the varying dose sensitivity of different organs. Our riskTCM framework assumes that a coarse CT reconstruction, an organ segmentation, and an estimation of the dose distribution can be provided in real time, for example, by applying machine learning techniques. Using this information, riskTCM determines a tube current curve that minimizes a patient risk measure, for example, the effective dose, while keeping the image quality constant. We retrospectively applied riskTCM to 20 patients covering all relevant anatomical regions and tube voltages from 70 to 150 kV. The potential reduction of effective dose at same image noise is evaluated as a figure of merit and compared to mAsTCM and to a situation with a constant tube current referred to as noTCM. RESULTS: Anatomical regions like the neck, thorax, abdomen, and the pelvis benefit from the proposed riskTCM. On average, a reduction of effective dose of about 23% for the thorax, 31% for the abdomen, 24% for the pelvis, and 27% for the neck has been evaluated compared to today's state-of-the-art mAsTCM. For the head, the resulting reduction of effective dose is lower, about 13% on average compared to mAsTCM. CONCLUSIONS: With a risk-minimizing TCM, significant higher reduction of effective dose compared to mAs-minimizing TCM is possible.


Asunto(s)
Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Dosis de Radiación , Estudios Retrospectivos , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos
14.
Med Phys ; 49(4): 2259-2269, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35107176

RESUMEN

PURPOSE: With the rising number of computed tomography (CT) examinations and the trend toward personalized medicine, patient-specific dose estimates are becoming more and more important in CT imaging. However, current approaches are often too slow or too inaccurate to be applied routinely. Therefore, we propose the so-called deep dose estimation (DDE) to provide highly accurate patient dose distributions in real time METHODS: To combine accuracy and computational performance, the DDE algorithm uses a deep convolutional neural network to predict patient dose distributions. To do so, a U-net like architecture is trained to reproduce Monte Carlo simulations from a two-channel input consisting of a CT reconstruction and a first-order dose estimate. Here, the corresponding training data were generated using CT simulations based on 45 whole-body patient scans. For each patient, simulations were performed for different anatomies (pelvis, abdomen, thorax, head), different tube voltages (80 kV, 100 kV, 120 kV), different scan trajectories (circle, spiral), and with and without bowtie filtration and tube current modulation. Similar simulations were performed using a second set of eight whole-body CT scans from the Visual Concept Extraction Challenge in Radiology (Visceral) project to generate testing data. Finally, the DDE algorithm was evaluated with respect to the generalization to different scan parameters and the accuracy of organ dose and effective dose estimates based on an external organ segmentation. RESULTS: DDE dose distributions were quantified in terms of the mean absolute percentage error (MAPE) and a gamma analysis with respect to the ground truth Monte Carlo simulation. Both measures indicate that DDE generalizes well to different scan parameters and different anatomical regions with a maximum MAPE of 6.3% and a minimum gamma passing rate of 91%. Evaluating the organ dose values for all organs listed in the International Commission on Radiological Protection (ICRP) recommendation, shows an average error of 3.1% and maximum error of 7.2% (bone surface). CONCLUSIONS: The DDE algorithm provides an efficient approach to determine highly accurate dose distributions. Being able to process a whole-body CT scan in about 1.5 s, it provides a valuable alternative to Monte Carlo simulations on a graphics processing unit (GPU). Here, the main advantage of DDE is that it can be used on top of any existing Monte Carlo code such that real-time performance can be achieved without major adjustments. Thus, DDE opens up new options not only for dosimetry but also for scan and protocol optimization.


Asunto(s)
Tomografía Computarizada por Rayos X , Humanos , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos
15.
Med Phys ; 49(1): 93-106, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34796532

RESUMEN

PURPOSE: Various studies have demonstrated that additional prefilters and/or reduced tube voltages have the potential to significantly increase the contrast-to-noise ratios at unit dose (CNRDs) and thereby to significantly reduce patient dose in clinical CT. An exhaustive analysis, accounting for a wide range of filter thicknesses and a wide range of tube voltages extending beyond the 70 to 150 kV range of today's CT systems, including their specific choice depending on the patient size, is, however, missing. Therefore, this work analyzes the dose reduction potential for patient-specific selectable prefilters combined with a wider range of tube voltages. We do so for soft tissue and iodine contrast in single energy CT. The findings may be helpful to guide further developments of x-ray tubes and automatic filter changers. METHODS: CT acquisitions were simulated for different patient sizes (semianthropomorphic phantoms for child, adult, and obese patients), tube voltages (35-150 kV), prefilter materials (tin and copper), and prefilter thicknesses (up to 5 mm). For each acquisition soft tissue and iodine CNRDs were determined. Dose was calculated using Monte Carlo simulations of a computed tomography dose index (CTDI) phantom. CNRD values of acquisitions with different parameters were used to evaluate dose reduction. RESULTS: Dose reduction through patient-specific prefilters depends on patient size and available tube current among others. With an available tube current time product of 1000 mAs dose reductions of 17% for the child, 32% for the adult and 29% for the obese phantom were achieved for soft tissue contrast. For iodine contrast dose reductions were 57%, 49%, and 39% for child, adult, and obese phantoms, respectively. Here, a tube voltage range extended to lower kV is important. CONCLUSIONS: Substantial dose reduction can be achieved by utilizing patient-specific prefilters. Tube voltages lower than 70 kV are beneficial for dose reduction with iodine contrast, especially for small patients. The optimal implementation of patient-specific prefilters benefits from higher tube power. Tin prefilters should be available in 0.1 mm steps or lower, copper prefilter in 0.3 mm steps or lower. At least 10 different prefilter thicknesses should be used to cover the dose optima of all investigated patient sizes and contrast mechanisms. In many cases it would be advantageous to adapt the prefilter thickness rather than the tube current to the patient size, that is, to always use the maximum available tube current and to control the exposure by adjusting the thickness of the prefilter.


Asunto(s)
Reducción Gradual de Medicamentos , Tomografía Computarizada por Rayos X , Adulto , Niño , Humanos , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación
16.
Med Phys ; 48(7): 3559-3571, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33959983

RESUMEN

PURPOSE: During a typical cardiac short scan, the heart can move several millimeters. As a result, the corresponding CT reconstructions may be corrupted by motion artifacts. Especially the assessment of small structures, such as the coronary arteries, is potentially impaired by the presence of these artifacts. In order to estimate and compensate for coronary artery motion, this manuscript proposes the deep partial angle-based motion compensation (Deep PAMoCo). METHODS: The basic principle of the Deep PAMoCo relies on the concept of partial angle reconstructions (PARs), that is, it divides the short scan data into several consecutive angular segments and reconstructs them separately. Subsequently, the PARs are deformed according to a motion vector field (MVF) such that they represent the same motion state and summed up to obtain the final motion-compensated reconstruction. However, in contrast to prior work that is based on the same principle, the Deep PAMoCo estimates and applies the MVF via a deep neural network to increase the computational performance as well as the quality of the motion compensated reconstructions. RESULTS: Using simulated data, it could be demonstrated that the Deep PAMoCo is able to remove almost all motion artifacts independent of the contrast, the radius and the motion amplitude of the coronary artery. In any case, the average error of the CT values along the coronary artery is about 25 HU while errors of up to 300 HU can be observed if no correction is applied. Similar results were obtained for clinical cardiac CT scans where the Deep PAMoCo clearly outperforms state-of-the-art coronary artery motion compensation approaches in terms of processing time as well as accuracy. CONCLUSIONS: The Deep PAMoCo provides an efficient approach to increase the diagnostic value of cardiac CT scans even if they are highly corrupted by motion.


Asunto(s)
Vasos Coronarios , Aprendizaje Profundo , Algoritmos , Artefactos , Vasos Coronarios/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Movimiento (Física) , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
17.
Curr Opin Chem Biol ; 63: 163-170, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34051510

RESUMEN

Molecular imaging is a valuable tool in drug discovery and development, early screening and diagnosis of diseases, and therapy assessment among others. Although many different imaging modalities are in use today, molecular imaging with computed tomography (CT) is still challenging owing to its low sensitivity and soft tissue contrast compared with other modalities. Recent technical advances, particularly the introduction of spectral photon-counting detectors, might allow overcoming these challenges. Herein, the fundamentals and recent advances in CT relevant to molecular imaging are reviewed and potential future preclinical and clinical applications are highlighted. The review concludes with a discussion of potential future advancements of CT for molecular imaging.


Asunto(s)
Medios de Contraste/química , Imagen Molecular/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Animales , Cesio/química , Gadolinio/química , Humanos , Procesamiento de Imagen Asistido por Computador , Yoduros/química , Metales/química , Imagen Molecular/métodos , Nanopartículas/química , Fotones , Sarcoma/diagnóstico por imagen , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
18.
Med Phys ; 48(7): 3572-3582, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33973237

RESUMEN

PURPOSE: Metal artifacts can drastically reduce the diagnostic value of computed tomography (CT) images. Even the state-of-the-art algorithms cannot remove them completely. Photon-counting CT inherently provides spectral information, similar to dual-energy CT. Many applications, such as material decomposition, are not possible when metal artifacts are present. Our aim is to develop a prior-based metal artifact reduction specifically for photon-counting CT that can correct each bin image individually or in their combinations. METHODS: Photon-counting CT sorts incoming photons into several energy bins, producing bin and threshold images containing spectral information. We use this spectral information to obtain a better prior image for the state-of-the-art metal artifact reduction algorithm FSNMAR. First, we apply a non-linear transformation to the bin images to obtain bone-emphasized images. Subsequently, we forward-project the bin images and bone-emphasized images and multiply the resulting sinograms with each other element-wise to mimic beam hardening effects. These sinograms are reconstructed and linearly combined to produce an artifact-reduced image. The coefficients of this linear combination are automatically determined by minimizing a threshold-based cost function in the image domain. After thresholding, we obtain the prior image for FSNMAR, which is applied to the individual bin images and the lowest threshold image. We test our photon-counting normalized metal artifact reduction (PCNMAR) on forensic CT data and compare it to conventional FSNMAR, where the prior is generated via linear sinogram inpainting. For numerical analysis, we compute both the standard deviation in an ROI with metal artifacts and the CNR of soft tissue and fat. RESULTS: PCNMAR can effectively reduce metal artifacts without sacrificing the overall image quality. Compared to FSNMAR, our method produces fewer secondary artifacts and is more consistent with the measurements. Areas that contain metal, air, and soft tissue are more accurate in PCNMAR. In some cases, the standard deviation in the artifact ROI is reduced by more than 50% relative to FSNMAR, while the CNR values are similar. If extreme artifacts are present, PCNMAR is unable to outperform FSNMAR. Using either two, four, or only the highest energy bin to produce the prior image yielded comparable results. CONCLUSIONS: PCNMAR is an effective method of reducing metal artifacts in photon-counting CT. The spectral information available in photon-counting CT is highly beneficial for metal artifact reduction, especially the high-energy bin, which inherently contains fewer artifacts. While scanning with four instead of two bins does not provide a better artifact reduction, it allows for more freedom in the selection of energy thresholds.


Asunto(s)
Artefactos , Fotones , Algoritmos , Procesamiento de Imagen Asistido por Computador , Metales , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
19.
Med Phys ; 47(12): 6179-6190, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33011992

RESUMEN

PURPOSE: In clinics, only iodine- and barium-based contrast agents are currently used for contrast-enhanced x-ray computed tomography (CT). Recently, the introduction of new photon-counting (PC) detectors increased the interest in developing new contrast agents based on heavier elements. These elements may provide more contrast and spectral information compared to iodine and barium thanks to their k-edges at higher energies. In this paper, the potential of high-Z elements in contrast-enhanced CT was evaluated for different patient sizes and x-ray spectra using a PC detector. METHODS: An adult liver phantom with five high-Z element solutions (iodine, gadolinium, ytterbium, tungsten, and bismuth) was scanned with a whole-body photon-counting computed tomography (PCCT) prototype. For each element, the contrast-to-noise ratio at unit concentration and at unit dose (CNRCD) was evaluated in low threshold images ( T 0 = 20 keV ) as function of the tube voltage (80, 100, 120, and 140 kV) and in bin images (tube voltage = 120 kV) as function of the higher threshold ( T 0 = 20 keV and T 1 ∈ [ 50 , 90 ] keV ). Simulations were performed for validation with measurements and to investigate more elements (cerium and gold), different patient sizes (infant, adult, and obese), and spectrum filtration (with and without 0.4-mm tin filter). The dose reductions associated with the CNRCD improvements over iodine were quantified as well. RESULTS: CNRCD improvements and dose reductions depend on the investigated scenario. For the infant phantom, dose reductions around 30% were reached using cerium or gadolinium in combination with the tin filter. For the adult and obese phantom, reductions around 50% were provided by gadolinium or ytterbium in combination with the tin filter. Independently of the high-Z element, the CNRCD of two optimally combined bin images was higher than the CNRCD of the low threshold image. Good agreement was found between measurements and simulations. CONCLUSIONS: Between the investigated elements, gadolinium resulted to have the highest potential as novel contrast agent in PCCT, providing significant dose reductions for all patient sizes. Compared to the other elements, the implementation of gadolinium as CT contrast agent may be facilitated since it is already deployed as contrast agents for magnetic resonance imaging.


Asunto(s)
Medios de Contraste , Yodo , Adulto , Humanos , Fantasmas de Imagen , Fotones , Tomografía Computarizada por Rayos X
20.
Sci Rep ; 10(1): 16866, 2020 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-33033290

RESUMEN

Coronary computed tomography angiography is an established technique in clinical practice and a valuable tool in the diagnosis of coronary artery disease in humans. Imaging of coronaries in preclinical research, i.e. in small animals, is very difficult due to the high demands on spatial and temporal resolution. Mice exhibit heart rates of up to 600 beats per minute motivating the need for highest detector framerates while the coronaries show diameters below 100 µm indicating the requirement for highest spatial resolution. We herein use a custom built micro-CT equipped with dedicated reconstruction algorithms to illustrate that coronary imaging in mice is possible. The scanner provides a spatial and temporal resolution sufficient for imaging of smallest, moving anatomical structures and the dedicated reconstruction algorithms reduced radiation dose to less than 1 Gy but do not yet allow for longitudinal studies. Imaging studies were performed in ten mice administered with a blood-pool contrast agent. Results show that the course of the left coronary artery can be visualized in all mice and all major branches can be identified for the first time using micro-CT. This reduces the gap in cardiac imaging between clinical practice and preclinical research.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Microtomografía por Rayos X/métodos , Animales , Angiografía por Tomografía Computarizada/instrumentación , Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Ratones Endogámicos C57BL , Microtomografía por Rayos X/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA