Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
BMC Sports Sci Med Rehabil ; 16(1): 16, 2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38218881

RESUMEN

The ability to obtain dynamic movement assessments using force plate technology holds the promise of providing more detailed knowledge of the strength, balance and forces generated by active-duty military personnel. To date, there are not well-defined use cases for implementation of force plate assessments in military training environments. We sought to determine if force plate technology assessments could provide additional insights, related to the likelihood of graduation, beyond that provided by traditional physical fitness tests (PFT's), in an elite Marine training school. Serial force plate measures were also obtained on those Marines successfully completing training to determine if consistent measures reflecting the effects of training on muscle skeletal load-over-time could be accurately measured. A pre-training force plate assessment performed in 112 Marines did not predict graduation rates. For Marines who successfully completed the course, serial measures obtained throughout training were highly variable for each individual and no firm conclusions could be drawn related to load imposed or the fitness attained during training.

2.
Curr Sports Med Rep ; 20(9): 436-439, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34524184

RESUMEN

ABSTRACT: The recent partnership of NFL's Next Gen Stats with Amazon Web Services has created a buzz among media and fans, yet the full scope and utility of digital biosensors has yet to be determined. We review current uses of Global Positioning System technology and digital biosensors in the NFL and discuss the future role of this technology in injury prevention. A complete literature review was conducted, along with review of the NFL web site and news outlet articles, to obtain a comprehensive assessment of all prior and current uses of biosensor technology in the NFL. Limited data exist on successful injury prevention and return to play, and utilization of this emerging technology has mostly been for fan experience. While ethical and legal challenges exist, the integration of digital biosensor and GPS technology in the NFL has enormous potential and is an invaluable tool in the comprehensive assessment of player health.


Asunto(s)
Traumatismos en Atletas/prevención & control , Fútbol Americano , Fútbol Americano/lesiones , Sistemas de Información Geográfica , Humanos , Tecnología
3.
JACC Heart Fail ; 9(6): 439-449, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33992570

RESUMEN

OBJECTIVES: The aim of this study was to determine whether patients with heart failure with reduced ejection fraction (HFrEF) due to nonischemic etiology eligible for cardiac resynchronization therapy (CRT) benefit from an implantable cardioverter-defibrillator (ICD). BACKGROUND: It is uncertain whether CRT with an ICD (CRT-D) compared to without an ICD (CRT-P) is associated with a survival benefit in patients with nonischemic etiologies of HFrEF. METHODS: Analyses of the COMPANION (Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure) trial were performed, using Cox proportional hazards modeling stratified by HFrEF etiology of nonischemic cardiomyopathy (NICM) or ischemic cardiomyopathy (ICM). The primary outcome was all-cause mortality (ACM), and secondary outcomes were the combination of cardiovascular mortality or heart failure hospitalization and sudden cardiac death. RESULTS: Among patients randomized to CRT (n = 1,212), 236 (19.5%) died, 131 and 105 in the CRT-P and CRT-D arms, respectively. The unadjusted and adjusted hazard ratios (HRs) for CRT-D versus CRT-P were both 0.84 (95% confidence interval [CI]: 0.65 to 1.09) for ACM, with a significant device-etiology interaction (pinteraction = 0.015 adjusted; pinteraction = 0.040 unadjusted). In patients with NICM (n = 555), CRT-D versus CRT-P was associated with reduced ACM (adjusted HR: 0.54; 95% CI: 0.34 to 0.86), while patients with ICM (n = 657) did not exhibit a between-device reduction in ACM (adjusted HR: 1.05; 95% CI: 0.77 to 1.44). The effects of CRT-D versus CRT-P on sudden cardiac death (advantage CRT-D) and cardiovascular mortality or heart failure hospitalization (no difference between CRT-P and CRT-D) were similar between the 2 HFrEF etiologies. CONCLUSIONS: COMPANION patients with NICM exhibited a decrease in ACM associated with CRT-D but not CRT-P treatment, whereas patients with ICM did not.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatías , Desfibriladores Implantables , Insuficiencia Cardíaca , Cardiomiopatías/terapia , Insuficiencia Cardíaca/terapia , Humanos , Volumen Sistólico , Resultado del Tratamiento
4.
Curr Cardiol Rep ; 23(1): 1, 2020 11 20.
Artículo en Inglés | MEDLINE | ID: mdl-33216256

RESUMEN

PURPOSE OF REVIEW: Despite the promise of remote patient monitoring (RPM), this technology remained underutilized secondary to a lack of data transparency and systems issues until the COVID-19 pandemic ushered in a new era of telehealth and virtual solutions out of necessity. This review will explore the data supporting the use of RPM via both implantable and wearable devices in the field of cardiology and the role of home monitoring using RPM in the era of COVID-19. RECENT FINDINGS: RPM using implantable cardiac devices is a safe alternative to in-person only visits which leads to enhanced patient satisfaction and improved clinical outcomes. Consumer-grade wearable sensors have drastically expanded RPM capabilities from just the sickest cardiac patients to the entire population aiding in early diagnosis and real-time disease management. Home monitoring enabled by automated alert systems tailored specifically to the needs of the patient by the provider will be the cornerstone of a more continuous, patent-centric healthcare model.


Asunto(s)
COVID-19 , Desfibriladores Implantables , Telemedicina , Humanos , Pandemias , SARS-CoV-2
5.
Cardiovasc Digit Health J ; 1(3): 149-159, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33043314

RESUMEN

In December 2019, the novel COVID-19 virus spread from a cluster of pneumonia cases in Wuhan, China, to every corner of the globe, creating a worldwide pandemic pushing hospital systems past capacity and bringing economies worldwide to a halt. The COVID-19 pandemic is unique in comparison to prior coronavirus epidemics in its superior ability to be spread by asymptomatic and presymptomatic patients, allowing the virus to silently evade traditional symptoms-based screening approaches. Countries have implemented cutting-edge digital solutions to enhance traditional contact-tracing methodologies in combination with novel testing strategies to combat the virus, with variable levels of success. Despite having one of the most advanced and expensive health care systems in the world, the United States (U.S.) response is arguably one of the world's largest failures, as it leads the globe in case number as well as deaths. Until a successful vaccine can be broadly distributed, it is imperative that the U.S. curb the viral spread by rapidly developing a framework implementing both enhanced tracing and testing strategies balancing the needs of public health while respecting individual liberties. This review will explore the role of technology-augmented contact-based surveillance in tracking the outbreak in select countries in comparison to the current U.S. approach. It will evaluate barriers in the U.S. to implementing similar technologies, focusing on privacy concerns and a lack of unified testing and tracing strategy. Finally, it will explore strategies for rapidly scaling testing in a cost-effective manner.

9.
JACC Heart Fail ; 7(4): 281-290, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30738980

RESUMEN

OBJECTIVES: This study tested the hypothesis that the extent of left ventricular (LV) eccentric structural remodeling in heart failure with reduced ejection fraction (HFrEF) is directly associated with clinical event responses to cardiac resynchronization therapy (CRT). BACKGROUND: Whether the severity of LV structural remodeling influences CRT treatment effects is unknown. METHODS: COMPANION (Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure) trial data were analyzed retrospectively. Left ventricular internal dimensions at end diastole indexed by body surface area (LVEDDI) were measured pre-randomization by 2-dimensional echocardiography. LVEDDI values were stratified around the median value of 35 mm/m2, and CRT (including CRT-P [CRT with only pacing capability] and/or CRT-D [CRT with an implantable defibrillator]) treatment effects were assessed and compared by LVEDDI group. Patients assigned to these treatments were compared to those undergoing optimal pharmacologic therapy (OPT) for the outcomes of all-cause mortality (ACM) or ACM and heart-failure hospitalization (ACM/HFH). RESULTS: In the LVEDDI ≥35 mm/m2 group (n = 614), CRT vs. OPT was associated with a lower ACM/HFH hazard ratio (HR) (HR: 0.53; 95% confidence interval [CI]: 0.40 to 0.70; p <0.001), whereas in the LVEDDI <35 mm/m2 group, the CRT vs. OPT ACM/HFH hazard ratio was not statistically significant (HR: 0.80; 95% CI: 0.59 to 1.08; p = 0.15). For ACM alone, in the LVEDDI ≥35 mm/m2 group, the hazard ratio for CRT-P was 0.59 (95% CI: 0.39 to 0.90; p = 0.012) and for CRT-D 0.50 (95% CI: 0.32 to 0.77; p = 0.002). Neither of the CRT groups showed a statistically significant reduction in ACM in the LVEDDI <35 mm/m2 group. CONCLUSIONS: Larger versus smaller LVEDDIs are associated with a reduction in ACM with CRT-P or CRT-D treatment, and with a more effective reduction in ACM/HFH for the combined CRT treatment groups.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Remodelación Ventricular , Anciano , Ecocardiografía , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
11.
J Innov Card Rhythm Manag ; 10(9): 3822-3825, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32477751

RESUMEN

Since its introduction in 2015, the Apple Watch (Apple Inc., Cupertino, CA, USA) has been purchased by an estimated 60 million consumers and boasts algorithms cleared by the United States Food and Drug Administration able to detect bradycardia, tachycardia, and atrial fibrillation, with the newest version of the device also allowing for real-time electrocardiogram acquisition. This case offers potentially the first demonstration of an Apple Watch correctly detecting atrial fibrillation with an implantable cardioverter-defibrillator confirming the accuracy of the detection from stored electrograms.

12.
Heart Rhythm ; 16(4): 581-587, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30389442

RESUMEN

BACKGROUND: Athletes with an implantable cardioverter-defibrillator (ICD) may require unique optimal device-based tachycardia programming. OBJECTIVE: The purpose of this study was to assess the association of tachycardia programming characteristics of ICDs with occurrence of shocks, transient loss-of-consciousness, and death among athletes. METHODS: A subanalysis of a prospective, observational, international registry of 440 athletes with ICDs followed for a median of 44 months was performed. Programming characteristics were divided into groups for rate cutoff (very high, high, or low) and detection (long-detection interval [>nominal] or nominal). Endpoints included total, appropriate, and inappropriate shocks, transient loss-of-consciousness, and mortality. RESULTS: In this cohort, 62% were programmed with high-rate cutoff and 30% with long detection. No athlete died of an arrhythmia (related or unrelated) to ICD shocks. Three patients had sustained ventricular tachycardia below programmed detection rate, presenting as palpations and/or dizziness. ICD shocks were received by 98 athletes (64 appropriate, 32 inappropriate); 2 patients received both. Programming a high-rate cutoff was associated with decreased risk of total (P = .01) and inappropriate (P = .04) shocks overall and during competition or practice. Programming long-detection intervals was associated with fewer total shocks. Single- vs dual-chamber devices and the number of zones were unrelated to risk of shock. Transient loss-of-consciousness, associated with 27 appropriate shocks, was not related to programming characteristics. CONCLUSION: High-rate cutoff and long-detection duration programming of ICDs in athletes at risk for sudden death can reduce total and inappropriate ICD shocks without affecting survival or the incidence of transient loss-of-consciousness.


Asunto(s)
Atletas , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/normas , Adolescente , Adulto , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros
13.
Arrhythm Electrophysiol Rev ; 7(4): 294-298, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30588319

RESUMEN

ICDs and resynchronisation devices are routinely implanted in patients with heart failure for primary prevention of sudden cardiac death or to treat the condition. The addition of device features and algorithms that directly or indirectly monitor cardiac haemodynamics to assess heart failure status can provide additional benefit by treating heart failure more continuously. Established and emerging devices and sensors aimed at treating or measuring cardiac haemodynamics represent the next era of heart failure disease management. Digitally enabled models of heart failure care, based on frequent haemodynamic measurements, will increasingly involve patients in their own disease management. Software tools and services tailored to provide patients with personalised information to guide diet, activity, medications and haemodynamic management offer an unprecedented opportunity to improve patient outcomes. This will enable physicians to care for larger populations because management will be exception based, automated and no longer depend on one-to-one patient and physician interactions.

16.
J Cardiovasc Comput Tomogr ; 12(1): 16-27, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29198733

RESUMEN

Advances in imaging technology have led to a paradigm shift from planning of cardiovascular procedures and surgeries requiring the actual patient in a "brick and mortar" hospital to utilization of the digitalized patient in the virtual hospital. Cardiovascular computed tomographic angiography (CCTA) and cardiovascular magnetic resonance (CMR) digitalized 3-D patient representation of individual patient anatomy and physiology serves as an avatar allowing for virtual delineation of the most optimal approaches to cardiovascular procedures and surgeries prior to actual hospitalization. Pre-hospitalization reconstruction and analysis of anatomy and pathophysiology previously only accessible during the actual procedure could potentially limit the intrinsic risks related to time in the operating room, cardiac procedural laboratory and overall hospital environment. Although applications are specific to areas of cardiovascular specialty focus, there are unifying themes related to the utilization of technologies. The virtual patient avatar computer can also be used for procedural planning, computational modeling of anatomy, simulation of predicted therapeutic result, printing of 3-D models, and augmentation of real time procedural performance. Examples of the above techniques are at various stages of development for application to the spectrum of cardiovascular disease processes, including percutaneous, surgical and hybrid minimally invasive interventions. A multidisciplinary approach within medicine and engineering is necessary for creation of robust algorithms for maximal utilization of the virtual patient avatar in the digital medical center. Utilization of the virtual advanced cardiac imaging patient avatar will play an important role in the virtual health care system. Although there has been a rapid proliferation of early data, advanced imaging applications require further assessment and validation of accuracy, reproducibility, standardization, safety, efficacy, quality, cost effectiveness, and overall value to medical care.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Cardiopatías/diagnóstico por imagen , Cardiopatías/terapia , Imagen por Resonancia Magnética/métodos , Modelos Cardiovasculares , Modelación Específica para el Paciente , Terapia Asistida por Computador/métodos , Algoritmos , Diseño Asistido por Computadora , Humanos , Imagenología Tridimensional , Valor Predictivo de las Pruebas , Impresión Tridimensional , Diseño de Prótesis , Interpretación de Imagen Radiográfica Asistida por Computador , Terapia Asistida por Computador/instrumentación
18.
Heart Rhythm ; 14(6): 858-865, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28323173

RESUMEN

BACKGROUND: Controlled clinical trial data are lacking for cardiac resynchronization therapy (CRT) outcomes in patients with advanced heart failure (HF) from reduced left ventricular ejection fraction (HFrEF) and intermittent atrial fibrillation or flutter (IAF/AFL). OBJECTIVE: The purpose of this study was to describe CRT outcomes in patients with IAF/AFL and advanced HF. METHODS: HF outcomes in patients in the COMPANION (Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure) trial with New York Heart Association class III or IV HFrEF, left ventricular ejection fraction ≤0.35, sinus rhythm at randomization, and no history of baseline arrhythmia were compared with those with a history of IAF/AFL. RESULTS: In those with no history of baseline arrhythmia (n = 887), compared with optimal pharmacological therapy (OPT) with no CRT, the CRT + OPT arms exhibited a significant reduction in the end points of death or any hospitalization (hazard ratio [HR] 0.73 [95% Confidence Interval (CI): 0.60 to 0.89]; P = .002) and death or HF hospitalization (HR 0.53 [95% CI: 0.41 to 0.68]; P < .001). In contrast, in the IAF/AFL subgroup (n = 293), CRT did not result in improved outcomes compared with OPT (death or any hospitalization: HR 1.16 [95% CI: 0.83 to 1.63]; P = .38; death or HF hospitalization: HR 0.97 [95% CI: 0.64 to 1.46]; P = .88). The interaction between history of AF/AFL and CRT was statistically significant for both outcomes (P < .05). CONCLUSION: In the COMPANION trial, patients with moderate to severe HFrEF and a history of IAF/AFL had no benefit from CRT.


Asunto(s)
Fibrilación Atrial/terapia , Aleteo Atrial/terapia , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/complicaciones , Ventrículos Cardíacos/fisiopatología , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Anciano , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Aleteo Atrial/etiología , Aleteo Atrial/fisiopatología , Ecocardiografía , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Factores de Tiempo , Resultado del Tratamiento
19.
20.
Trends Cardiovasc Med ; 26(8): 722-730, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27373351

RESUMEN

Remote digital health monitoring technologies can be synergistically organized to create a virtual medical system providing more continuous care centered on the patient rather than the bricks and mortar medical complex. Utilization of the digitalized patient health monitoring can facilitate diagnosis, treatment plans, physician-patient interaction, and accelerate the progress of medical research, education, and training. The field of cardiac electrophysiology has been an early adopter of this shift in care and serves as a paradigm applicable to all areas of medicine. The overall impact of this remote virtual care model on the quality of medical care and patient experience requires greater study, as well as vigilance as to the differences between technology and care in order to preserve the intangible and immeasurable factors that bring humanity to the art and science of medicine.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/terapia , Prestación Integrada de Atención de Salud/métodos , Tecnología de Sensores Remotos/métodos , Telemedicina/métodos , Telemetría/métodos , Algoritmos , Enfermedades Cardiovasculares/fisiopatología , Vías Clínicas , Diseño de Equipo , Humanos , Aplicaciones Móviles , Valor Predictivo de las Pruebas , Pronóstico , Tecnología de Sensores Remotos/instrumentación , Procesamiento de Señales Asistido por Computador , Teléfono Inteligente , Telemedicina/instrumentación , Telemetría/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...