Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Pers Med ; 14(3)2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38541044

RESUMEN

Despite significant improvements in techniques, the treatment of neonates and infants with congenital heart disease resulting in duct-dependent pulmonary circulation is still significantly challenging. Despite current trends toward early primary surgical repair, temporary palliation is still necessary in those patients who are at high surgical risk for complete correction due to unfavorable clinical or anatomic characteristics. Recent advances in interventional cardiology have led to the emergence of right ventricular outflow tract and arterial duct stenting as cost-effective alternatives to surgical palliation in high-risk surgical candidates or whenever short-term pulmonary blood flow support is anticipated. This review aims to explore the evolving landscape of these transcatheter approaches, highlighting their role, efficacy and potential complications in the context of duct-dependent pulmonary circulation anatomies.

2.
Am J Cardiol ; 211: 259-267, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37984644

RESUMEN

Transcatheter closure is the first-line treatment for ostium secundum atrial septal defect (ASD). The GORE Cardioform ASD Occluder (GCA) is potentially innovative compared with other self-centering devices. This study aimed to compare the mechanic changes in atrial and ventricular properties before and after GCA implantation. All consecutive patients aged <18 years who underwent isolated ASD closure with a single GCA device were enrolled from 2 centers. Echocardiography and electrocardiogram were performed the day before, 24 hours, and 6 months after ASD closure. Between January 2020 and February 2021, 70 pediatric patients with ASD were enrolled. The mean age was 7.9 ± 3.9 years, and the mean defect diameter was 17.1 ± 4.5 mm. Global longitudinal strain analysis showed no change in left ventricular longitudinal function (T0 -23.2 ± 2.8%, 24 hours -23.0 ± 2.8%, and 6 months -23.5 ± 2.7%). An early and transient reduction in longitudinal strain was detected in the basal septal segments (T0 -19.8 ± 3.3%, 24 hours -18.7 ± 3.6%, and 6 months -19.2 ± 3.4%), left atrium (T0 41.4 ± 15.3%, 29.2 ± 1.4%, and 39.0 ± 12.9%), and right ventricle (-27.6 ± 5.4%, -23.6 ± 5.0%, and -27.3 ± 4.6) 24 hours after closure, secondary to hemodynamic changes because of flow redirection after ASD closure. Six months after the procedure, only the left atrium showed a mild global longitudinal strain reduction because of the presence of the device within the septum. GCA device had no impact on global and regional ventricular function. Atrial mechanics were preserved, except for the segments covered by the device. This is the first device demonstrating no impact on the left and right ventricular mechanics, irrespective of the device size.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Humanos , Niño , Preescolar , Ventrículos Cardíacos/diagnóstico por imagen , Resultado del Tratamiento , Cateterismo Cardíaco , Atrios Cardíacos/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía
3.
Eur Heart J Case Rep ; 7(11): ytad467, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37942352

RESUMEN

Background: Percutaneous closure is nowadays still deemed challenging in patent forame ovale (PFO) associated to multi-fenestrated atrial septal aneurysm (ASA). This anatomic arrangement is still considered a significant risk factor for recurrence of paradoxical embolism. Theoretically, transcatheter approach could be theoretically even more complex in the case of dextrocardia and visceral situs inversus. Case summary: A 59-year-old man with history of migraine with aura and multiple cryptogenic strokes was referred for percutaneous closure of a PFO with associated ASA. He had been previously submitted to repeat attempt of percutaneous closure with not self-centering and self-centering devices that failed due to unfavorable anatomic characteristics (dextrocardia with situs viscerum inversus, huge ASA, multiple fenestrations, large PFO). Based on this "complex" anatomy, a sequential 2-step interventional approach aiming to reduce size and mobility of the atrial septal aneurysm with a suture-based approach (Noblestich™ EL, HeartStitch, Fountain Valley, CA, USA) and to close any eventual accessory fenestrations with a not self-centering occluding device was planned. At the end of the procedure, the ASA completely disappeared and no residual shunt was imaged at TEE bubble test. Discussion: We describe a very rare case of symptomatic ASA-PFO in dextrocardia with situs viscerum inversus as well as an innovative approach to treat such complex anatomic setting by using the suture-based closure of a PFO to reduce size and mobility of an ASA in order to deploy dedicated not-self-centering occluding devices.

4.
JACC Case Rep ; 16: 101869, 2023 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-37396316

RESUMEN

We report on a 2-week-old infant with huge left main coronary artery-to-right ventricular outflow tract fistula causing myocardial ischemia due to global coronary steal who was successfully submitted to percutaneous closure guided by a 3-dimensional-printed model using a duct-occluder vascular plug. (Level of Difficulty: Advanced.).

5.
JACC Case Rep ; 10: 101764, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36974053

RESUMEN

Ascending aorta pseudoaneurysms represent uncommon but life-threatening complications that can be observed even after a long time in patients who have undergone aortic surgery. We describe an interesting case of a patient with ascending aorta pseudoaneurysm after the Bentall procedure treated with endovascular coil embolization from the right coronary artery. (Level of Difficulty: Intermediate.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...