1.
J Comput Assist Tomogr ; 47(6): 850-855, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37948358

RESUMEN

PURPOSE: The aim of the study is to assess the influence of manual adjustment of the Patlak range in computed tomography (CT) perfusion analysis of rectal carcinoma compared with default range of the perfusion software. METHODS: This study was approved by the institutional review board and informed consent was obtained. Twenty-one patients (12 male, 9 female; mean age ± SD, 59 ± 11 years) with rectal cancer were included and underwent perfusion CT before preoperative chemoradiotherapy. Equivalent blood volume (BV) and flow-extraction (FE) were calculated using the Patlak plot model. Two perfusion sets were calculated per patient, a perfusion set using the default setting as provided by the software (dBV, dFE) and an optimized perfusion set after manual adaption of the Patlak range (aBV, aFE), which was limited to the intravascular space clearance of contrast to the extravascular space. Perfusion values calculated with both methods were compared for significance in differences using the Wilcoxon test. A P value of 0.05 or less was defined as statistically significant. RESULTS: Adjustment of the Patlak range statistically significantly influenced BV and FE calculation. Median dBV was 23.2 mL/100 mL (interquartile range [IQR], 12.1 mL/100 mL), whereas median aBV was 20.3 mL/100 mL (IQR, 10.9 mL/100 mL). The difference in BV was statistically significant ( P = 0.021). Median dFE was 8.3 mL/min/100 mL (IQR, 4.7 mL/min/100 mL), whereas median aFE was 15.4 mL/min/100 mL (IQR, 5.8 mL/min/100 mL). The difference in FE was statistically significant ( P < 0.001). CONCLUSIONS: Our findings indicate that in perfusion CT of rectal carcinoma, adjustment of the Patlak range may significantly influence BV and FE compared with default setting of the software. This may contribute to standardization in the use of this technique for functional imaging of rectal cancer.


Asunto(s)
Carcinoma , Neoplasias del Recto , Humanos , Masculino , Femenino , Tomografía Computarizada por Rayos X/métodos , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/terapia , Volumen Sanguíneo , Perfusión
2.
Eur J Radiol ; 165: 110931, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37399666

RESUMEN

PURPOSE: To investigate whether CT texture analysis allows differentiation between adenocarcinomas, squamous cell carcinomas, carcinoids, small cell lung cancers and organizing pneumonia and between carcinomas and neuroendocrine tumors. METHOD: This retrospective study included patients 133 patients (30 patients with organizing pneumonia, 30 patients with adenocarcinoma, 30 patients with squamous cell carcinoma, 23 patients with small cell lung cancer, 20 patients with carcinoid), who underwent CT-guided biopsy of the lung and had a corresponding histopathologic diagnosis. Pulmonary lesions were segmented in consensus by two radiologists with and without a threshold of -50HU in three dimensions. Groupwise comparisons were performed to assess for differences between all five above-listed entities and between carcinomas and neuroendocrine tumors. RESULTS: Pairwise comparisons of the five entities revealed 53 statistically significant texture features when using no HU-threshold and 6 statistically significant features with a threshold of -50HU. The largest AUC (0.818 [95%CI 0.706-0.930]) was found for the feature wavelet-HHH_glszm_SmallAreaEmphasis for discrimination of carcinoid from the other entities when using no HU-threshold. In differentiating neuroendocrine tumors from carcinomas, 173 parameters proved statistically significant when using no HU threshold versus 52 parameters when using a -50HU-threshold. The largest AUC (0.810 [95%CI 0.728-0,893]) was found for the parameter original_glcm_Correlation for discrimination of neuroendocrine tumors from carcinomas when using no HU-threshold. CONCLUSIONS: CT texture analysis revealed features that differed significantly between malignant pulmonary lesions and organizing pneumonia and between carcinomas and neuroendocrine tumors of the lung. Applying a HU-threshold for segmentation substantially influenced the results of texture analysis.


Asunto(s)
Adenocarcinoma , Tumor Carcinoide , Carcinoma Neuroendocrino , Carcinoma de Células Escamosas , Neoplasias Pulmonares , Tumores Neuroendocrinos , Neumonía Organizada , Neumonía , Humanos , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Estudios Retrospectivos , Pulmón/patología , Adenocarcinoma/patología , Tumor Carcinoide/patología , Carcinoma de Células Escamosas/patología , Tomografía Computarizada por Rayos X/métodos , Carcinoma Neuroendocrino/patología , Diferenciación Celular
3.
Front Cardiovasc Med ; 10: 1147166, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37180771

RESUMEN

Myocardial infarction (MI) may be visible on contrast-enhanced multidetector computed tomography (MDCT) scans of the abdomen. In the previous literature, potentially missed MI in abdominal MDCTs was not perceived as an issue in radiology. This retrospective single-center study assessed the frequency of detectable myocardial hypoperfusion in contrast-enhanced abdominal MDCTs. We identified 107 patients between 2006 and 2022 who had abdominal MDCTs on the same day or the day before a catheter-proven or clinically evident diagnosis of MI. After reviewing the digital patient records and applying the exclusion criteria, we included 38 patients, with 19 showing areas of myocardial hypoperfusion. All MDCT studies were non ECG-gated. The delay between the MDCT examination and MI diagnosis was shorter in studies with myocardial hypoperfusion (7.4±6.5 hours and 13.8±12.5 hours) but not statistically significant p=0.054. Only 2 of 19 (11%) of these pathologies had been noted in the written radiology reports. The most common cardinal symptom was epigastric pain (50%), followed by polytrauma (21%). STEMI was significantly more common in cases of myocardial hypoperfusion p=0.009. Overall, 16 of 38 (42%) patients died because of acute MI. Based on extrapolations using local MDCT rates, we estimate several thousand radiologically missed MI cases worldwide per year.

4.
Eur Radiol ; 33(5): 3064-3071, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36947188

RESUMEN

OBJECTIVE: Reproducibility problems are a known limitation of radiomics. The segmentation of the target lesion plays a critical role in texture analysis variability. This study's aim was to compare the interobserver reliability of manual 2D vs. 3D lung lesion segmentation with and without pre-definition of the volume using a threshold of - 50 HU. METHODS: Seventy-five patients with histopathologically proven lung lesions (15 patients each with adenocarcinoma, squamous cell carcinoma, small cell lung cancer, carcinoid, and organizing pneumonia) who underwent an unenhanced CT scan of the chest were included. Three radiologists independently segmented each lesion manually in 3D and 2D with and without pre-segmentation volume definition by a HU threshold, and shape parameters and original, Laplacian of Gaussian-filtered, and wavelet-based texture features were derived. To assess interobserver reliability and identify the most robust texture features, intraclass correlation coefficients (ICCs) for different segmentation settings were calculated. RESULTS: Shape parameters had high reliability (64-79% had excellent and good ICCs). Texture features had weak reliability levels, with the highest ICCs (38% excellent or good) found for original features in 3D segmentation without the use of a HU threshold. A small proportion (4.3-11.5%) of texture features had excellent or good ICC values at all segmentation settings. CONCLUSION: Interobserver reliability of texture features from CT scans of a heterogeneous collection of manually segmented lung lesions was low with a small proportion of features demonstrating high reliability independent of the segmentation settings. These results indicate a limited applicability of texture analysis and the need to define robust texture features in patients with lung lesions. KEY POINTS: • Our study showed a low reproducibility of texture features when 3 radiologists independently segmented lung lesions in CT images, which highlights a serious limitation of texture analysis. • Interobserver reliability of texture features was low regardless of whether the lesion was segmented in 2D and 3D with or without a HU threshold. • In contrast to texture features, shape parameters showed a high interobserver reliability when lesions were segmented in 2D vs. 3D with and without a HU threshold of - 50.


Asunto(s)
Adenocarcinoma , Neoplasias Pulmonares , Humanos , Reproducibilidad de los Resultados , Adenocarcinoma/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/diagnóstico por imagen
5.
Eur Radiol ; 33(7): 4833-4841, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36806565

RESUMEN

OBJECTIVES: To assess the frequency of anterolateral ligament (ALL) tears and ramp lesions (RL) detected with MRI in patients with anterior cruciate ligament (ACL) tears and to describe associated injuries indicative for these lesions. METHODS: In this retrospective study, 164 patients with surgically verified ACL tears were included. Preoperative MRI scans were reviewed for ALL tears and different types of RL. All coexisting meniscal tears, tears of the medial (MCL) and lateral collateral band (LCL), and posterior-medial tibial bone marrow edema (BME) were recorded. The frequency of ALL tears and RL was assessed and coexisting injuries were correlated using Pearson's chi-square test. A p < 0.05 was defined as statistically significant. In cases of multiple testing, Bonferroni's correction was applied. RESULTS: ALL tears and RL combined were detected in 28 patients (17.1%), ALL tears in 48 patients (29.3%), and RL in 54 patients (32.9%) which were significantly associated to each other. ALL tears were significantly associated with tears of the posterior horn of the lateral meniscus (PHLM), BME, and with tears of the LCL and MCL. RL were significantly associated with tears of the posterior horn of the medial (PHMM) and PHLM, with BME, and with tears of the LCL. CONCLUSIONS: ACL tears are associated with RL or ALL tears in about one-third of cases and with both lesions combined in about one-fifth of cases. ALL tears and RL are significantly associated with additional posttraumatic injuries, which can thus be indicative of these lesions. KEY POINTS: • ACL tears were associated with ramp lesions or ALL tears in about one-third of the cases. • Ramp lesions and ALL tears were significantly associated with each other, tear in the PHLM, tear in the LCL, and BME. • ALL tears were more frequently associated with instable classified ramp lesion type 4b and type 5.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Lesiones de Menisco Tibial , Humanos , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/complicaciones , Estudios Retrospectivos , Meniscos Tibiales/patología , Ligamentos , Imagen por Resonancia Magnética
7.
Front Surg ; 9: 1013389, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36277287

RESUMEN

Objective: Guidelines for previous negative biopsy (PNB) cohorts with a suspicion of prostate cancer (PCa) after positive multiparametric (mp) magnetic-resonance-imaging (MRI) often favour the fusion-guided targeted prostate-biopsy (TB) only approach for Prostate Imaging-Reporting and Data System (PI-RADS) ≥3 lesions. However, recommendations lack direct biopsy performance comparison within biopsy naïve (BN) vs. PNB patients and its prognostication of the whole mount pathology report (WMPR), respectively. We suppose, that the combination of TB and concomitant TRUS-systematic biopsy (SB) improves the PCa detection rate of PI-RADS 2, 3, 4 or 5 lesions and the International Society of Urological Pathology (ISUP)-grade predictability of the WMPR in BN- and PNB patients. Methods: Patients with suspicious mpMRI, elevated prostate-specific-antigen and/or abnormal digital rectal examination were included. All PI-RADS reports were intramurally reviewed for biopsy planning. We compared the PI-RADS score substratified TB, SB or combined approach (TB/SB) associated BN- and PNB-PCa detection rate. Furthermore, we assessed the ISUP-grade variability between biopsy cores and the WMPR. Results: According to BN (n = 499) vs. PNB (n = 314) patients, clinically significant (cs) PCa was detected more frequently by the TB/SB approach (62 vs. 43%) than with the TB (54 vs. 34%) or SB (57 vs. 34%) (all p < 0.0001) alone. Furthermore, we observed that the TB/SB strategy detects a significantly higher number of csPCa within PI-RADS 3, 4 or 5 reports, both in BN and PNB men. In contrast, applied biopsy techniques were equally effective to detect csPCa within PI-RADS 2 lesions. In case of csPCa diagnosis the TB approach was more often false-negative in PNB patients (BN 11% vs. PNB 19%; p = 0.02). The TB/SB technique showed in general significantly less upgrading, whereas a higher agreement was only observed for the total and BN patient cohort. Conclusion: Despite csPCa is more frequently found in BN patients, the TB/SB method always detected a significantly higher number of csPCa within PI-RADS 3, 4 or 5 reports of our BN and PNB group. The TB/SB strategy predicts the ISUP-grade best in the total and BN cohort and in general shows the lowest upgrading rates, emphasizing its value not only in BN but also PNB patients.

8.
Abdom Radiol (NY) ; 47(12): 4151-4159, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36104481

RESUMEN

PURPOSE: To evaluate the utility of non-contrast-enhanced CT texture analysis (CTTA) for predicting the histopathological differentiation of pancreatic ductal adenocarcinomas (PDAC) and to compare non-contrast-enhanced CTTA texture features between primary PDAC and hepatic metastases of PDAC. METHODS: This retrospective study included 120 patients with histopathologically confirmed PDAC. Sixty-five patients underwent CT-guided biopsy of primary PDAC, while 55 patients underwent CT-guided biopsy of hepatic PDAC metastasis. All lesions were segmented in non-contrast-enhanced CT scans for CTTA based on histogram analysis, co-occurrence matrix, and run-length matrix. Statistical analysis was conducted for 372 texture features using Mann-Whitney U test, Bonferroni-Holm correction, and receiver operating characteristic (ROC) analysis. A p value < 0.05 was considered statistically significant. RESULTS: Three features were identified that differed significantly between histopathological G2 and G3 primary tumors. Of these, "low gray-level zone emphasis" yielded the largest AUC (0.87 ± 0.04), reaching a sensitivity and specificity of 0.76 and 0.83, respectively, when a cut-off value of 0.482 was applied. Fifty-four features differed significantly between primary and hepatic metastatic PDAC. CONCLUSION: Non-contrast-enhanced CTTA of PDAC identified differences in texture features between primary G2 and G3 tumors that could be used for non-invasive tumor assessment. Extensive differences between the features of primary and metastatic PDAC on CTTA suggest differences in tumor microenvironment.


Asunto(s)
Adenocarcinoma , Carcinoma Ductal Pancreático , Neoplasias Hepáticas , Neoplasias Pancreáticas , Humanos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Microambiente Tumoral , Neoplasias Pancreáticas
10.
Eur J Radiol ; 141: 109778, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34174486

RESUMEN

PURPOSE: To assess correlations of lean body weight (LBW) calculated with various formulas, total body weight (TBW), body height (BH), body mass index (BMI), body surface area (BSA) and fat-free mass (FFM) with vascular and parenchymal enhancement in multiphasic CT of the liver. METHOD: Thirty consecutive patients underwent multiphasic CT of the liver using constant iodine dose and flow rate. Contrast enhancement of aorta, portal vein and liver was calculated by measuring mean vascular and parenchymal attenuation in pre-contrast and post-contrast phases. Correlations of TBW, BH, BMI, BSA, FFM, and LBW (calculated with formulas of Boer, Hume, James and Green&Duffull) with enhancement were tested using Spearman's correlation coefficient. The method of Fieller et al. was used to calculate 95 % confidence intervals. A p-value ≤ 0.05 was considered statistically significant. RESULTS: Aortal enhancement correlated strongly with TBW, BSA, LBWBoer and LBWHume and moderately with BH, BMI, FFM, LBWJames and LBWGreen&Duffull. Liver enhancement in the late arterial phase correlated moderately with TBW, FFM, LBWBoer, LBWHume and LBWGreen&Duffull and weakly with BSA. Liver enhancement in the portal venous phase correlated strongly with TBW, BSA, FFM, LBWBoer, LBWHume and LBWGreen&Duffull, whereby overlap of the 95 % CI graphs demonstrated that the differences in the correlation coefficients were not statistically significant. Liver enhancement in the delayed phase correlated moderately with BH but did not correlate significantly with any other parameter. CONCLUSION: Regardless of the form used for calculation, LBW did not correlate statistically significantly stronger than TBW with vascular or parenchymal enhancement of the liver.


Asunto(s)
Benchmarking , Medios de Contraste , Peso Corporal , Humanos , Hígado/diagnóstico por imagen , Tomografía Computarizada por Rayos X
11.
Anticancer Res ; 39(7): 3847-3854, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31262912

RESUMEN

BACKGROUND/AIM: The liver is a frequent site for metastases of colorectal cancer. Approximately 15% of patients have hepatic metastases at the time of diagnosis and another 50% develop them over the course of their disease. Only 10-25% of patients are candidates for liver resection. The aim of this study was to assess the benefit of preoperative computed tomography (CT)-guided wire marking of disappearing colorectal liver metastases (CRLMs) (radiological disappearance of metastases) before surgical resection. PATIENTS AND METHODS: Between January 2011 and January 2014, 20 patients with potentially disappearing CRLMs were selected for CT-guided wire marking. Following treatment with neoadjuvant chemotherapy, disappearing CRLMs were marked via CT guidance. Afterwards, the marked sites were resected. RESULTS: Complete histological response to neoadjuvant chemotherapy was only in 10 resected sites (18%), and 46 (82%) resected liver metastases showed metastatic tissue present. Both overall survival and the disease-free rates in patients after using our method were 55%. CONCLUSION: This study demonstrated the usefulness of CT-guided wire marking to mark disappearing CRLMs in order to improve long-term effectiveness of surgical treatment.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Anciano , Antineoplásicos/uso terapéutico , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/tratamiento farmacológico , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/cirugía , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Masculino , Persona de Mediana Edad , Terapia Neoadyuvante , Proyectos Piloto , Análisis de Supervivencia , Tomografía Computarizada por Rayos X
12.
Wien Klin Wochenschr ; 130(21-22): 665-672, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30167887

RESUMEN

Rapid advances in imaging technology have improved the detection, characterization and staging of colorectal liver metastases, hepatocellular carcinoma and cholangiocarcinoma. A variety of imaging modalities are available and play a pivotal role in the work-up of patients, particularly as imaging findings determine resectability. Surgery often represents the only measure that can render long-term survival possible. Imaging is also indispensable for the assessment of responses to neoadjuvant treatment and for the detection of recurrence. At a consensus meeting held in June 2017 in Vienna, Austria, Austrian experts in the fields of surgery and radiology discussed imaging requirements prior to and after hepatic surgery for malignant liver lesions. This consensus was refined by online voting on a total of 47 items. Generally, the degree of consensus was high. The recommendations relate to the type of preferred preoperative imaging modalities, technical settings with respect to computed tomography and magnetic resonance imaging, use of contrast agents, reporting, postoperative follow-up, and long-term follow-up. Taking local resources into account, these consensus recommendations can be implemented in daily clinical practice at specialized centers as well as outpatient diagnostic institutes in Austria.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Austria , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Recurrencia Local de Neoplasia
13.
Anticancer Res ; 35(9): 4821-8, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26254373

RESUMEN

Gastroenteropancreatic neuroendocrine tumors are known for their aggressiveness. Diagnosis of various bile duct pathologies, like biliar intraepithelial neoplasm, mixed adenoneuroendocrine carcinomas or small cell carcinomas, is challenging. This case report focuses on a rare case of a focal primary minute small cell carcinoma in the vicinity of the extrahepatic bile duct, presenting itself next to an extensive biliar intraepithelial neoplasm. This finding led to adjuvant chemotherapy, followed by major surgery. Therapeutic approach was based on CT and MRI scans but most importantly on immunohistochemistry and histological evaluation. Initially CR seemed achievable, but metastases were to be found rapidly. The authors want to underline the fact that major clinical decisions are based on sometimes tiny specimens; as literature shows it is absolutely advisable to use markers to differentiate the dignity of investigated areas. The authors call for keeping collision of tumors in mind and adding KOC staining and using it in a routine manner examining biliary duct lesions.


Asunto(s)
Neoplasias de los Conductos Biliares/diagnóstico , Neoplasias de los Conductos Biliares/patología , Conductos Biliares Extrahepáticos/patología , Carcinoma in Situ/diagnóstico , Carcinoma in Situ/patología , Neoplasias Intestinales/diagnóstico , Neoplasias Intestinales/patología , Tumores Neuroendocrinos/diagnóstico , Tumores Neuroendocrinos/patología , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patología , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/patología , Humanos , Hígado/patología , Masculino , Persona de Mediana Edad , Clasificación del Tumor
14.
Eur J Radiol ; 83(8): 1416-20, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24931921

RESUMEN

PURPOSE: To compare the image quality and radiation dose between iterative reconstruction (IR) and standard filtered back projection (FBP) in CT of the chest and abdomen. MATERIALS AND METHODS: Thoracic CT was performed in 50 patients (38 male, 12 female; mean age, 51 ± 23 yrs; range, 7-85 yrs) and abdominal CT was performed in 50 patients (36 male, 14 female; mean age, 62 ± 13 yrs; range, 20-85 yrs), using IR as well as FBP for image reconstruction. Image noise was quantitatively assessed measuring standard deviation of Hounsfield Units (HU) in defined regions of interest in subcutaneous tissue. Scan length and Computed Tomography Dose Index (CTDI) were documented. Scan length, image noise, and CTDI of both reconstruction techniques were compared by using paired tests according to the nature of variables (McNemar test or Student t test). Overall subjective image quality and subjective image noise were compared. RESULTS: There was no significant difference between the protocols in terms of mean scan length (p>0.05). Image noise was statistically significantly higher with IR, although the difference was clinically insignificant (13.3 ± 3.0 HU and 13.6 ± 3.0 HU for thoracic CT and 11.5 ± 3.1 HU and 11.7 ± 3.0 HU for abdominal CT, p<0.05). There was no significant difference in overall subjective image quality and subjective image noise. The radiation dose was significantly lower with IR. Volume-weighted CTDI decreased by 64% (6.2 ± 2.5 mGy versus 17.1 ± 9.5 mGy, p<0.001) for thoracic CT and by 58% (7.8 ± 4.6 mGy versus 18.5 ± 8.6 mGy, p<0.001) for abdominal CT. CONCLUSIONS: Our study shows that in thoracic and abdominal CT with IR, there is no clinically significant impact on image quality, yet a significant radiation dose reduction compared to FBP.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mejoramiento de la Calidad , Dosis de Radiación , Radiografía Abdominal , Radiografía Torácica
15.
Eur J Radiol ; 83(4): 607-11, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24380639

RESUMEN

OBJECTIVES: To assess the correlation of relative hepatic enhancement (RHE), relative renal enhancement (RRE) and liver to kidneys enhancement ratio (LKR) with serum hepatic enzyme levels and eGFR in Gd-EOB-DTPA enhanced MRI of the liver and to assess threshold levels for predicting enhancement of the liver parenchyma. METHODS: Data of 75 patients who underwent Gd-EOB-DTPA enhanced MRI of the liver were collected. Images were obtained before contrast injection, during the early arterial phase, late arterial phase, venous phase, delayed phase, and hepatobiliary phase which was 20 min after Gd-EOB-DTPA administration. Signal intensity of the liver and the kidneys in all phases was defined using region-of-interest measurements for relative enhancement calculation. Serum hepatic enzyme levels and eGFR were available in all patients. Spearman correlation test was used to test the correlation of RHE, RRE and LKR with serum hepatic enzyme levels and eGFR. RESULTS: In the hepatobiliary phase all serum hepatic enzymes were significantly correlated with RHE; total bilirubin (TBIL) and cholin esterase (CHE) showed strongest correlations. TBIL and CHE were significantly correlated with RRE in the arterial phases. TBIL and CHE were significantly correlated with LKR in the arterial phase and hepatobiliary phase. eGFR showed no correlation. CONCLUSIONS: In Gd-EOB-DTPA enhanced MRI, TBIL and CHE levels may predict RHE, RRE and LKR.


Asunto(s)
Gadolinio DTPA/farmacocinética , Tasa de Filtración Glomerular , Riñón/diagnóstico por imagen , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/metabolismo , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Bilirrubina/sangre , Biomarcadores/sangre , Colinesterasas/sangre , Medios de Contraste/farmacocinética , Femenino , Humanos , Aumento de la Imagen/métodos , Riñón/metabolismo , Masculino , Persona de Mediana Edad , Cintigrafía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto
16.
PLoS One ; 8(2): e57931, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23469108

RESUMEN

PURPOSE: Temperature is a key measure in human red blood cell concentrate (RBC) quality control. A precise description of transient temperature distributions in RBC units removed from steady storage exposed to ambient temperature is at present unknown. Magnetic resonance thermometry was employed to visualize and analyse RBC warm up processes, to describe time courses of RBC mean, surface and core temperatures by an analytical model, and to determine and investigate corresponding model parameters. METHODS: Warm-up processes of 47 RBC units stored at 1-6°C and exposed to 21.25°C ambient temperature were investigated by proton resonance frequency thermometry. Temperature distributions were visualized and analysed with dedicated software allowing derivation of RBC mean, surface and core temperature-time courses during warm up. Time-dependence of mean temperature was assumed to fulfil a lumped capacitive model of heat transfer. Time courses of relative surface and core temperature changes to ambient temperature were similarly assumed to follow shifted exponential decays characterized by a time constant and a relative time shift, respectively. RESULTS: The lumped capacitive model of heat transfer and shifted exponential decays described time-dependence of mean, surface and core temperatures close to perfect (mean R(2) were 0.999±0.001, 0.996±0.004 and 0.998±0.002, respectively). Mean time constants were τmean = 55.3±3.7 min, τsurface = 41.4±2.9 min and τcore = 76.8±7.1 min, mean relative time shifts were Δsurface = 0.07±0.02 and Δcore = 0.04±0.01. None of the constants correlated significantly with temperature differences between ambient and storage temperature. CONCLUSION: Lumped capacitive model of heat transfer and shifted exponential decays represent simple analytical formulas to describe transient mean, surface and core temperatures of RBC during warm up, which might be a helpful tool in RBC temperature monitoring and quality control. Independence of constants on differences between ambient and storage temperature suggests validity of models for arbitrary storage and ambient temperatures.


Asunto(s)
Eritrocitos , Temperatura , Termometría/métodos , Humanos , Protones , Manejo de Especímenes , Factores de Tiempo
17.
Transfusion ; 53(1): 167-73, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22804564

RESUMEN

BACKGROUND: Recommended by current guidelines, red blood cell (RBC) temperature should not exceed 10°C during transport. Since warming is a generically three-dimensional process that is not homogeneous, it is necessary to clarify the term "temperature during warming." The purpose of this study was therefore to investigate laws and relations between surface, mean, and core temperature and the corresponding times when they exceed 10°C during warm-up. STUDY DESIGN AND METHODS: Time-resolved three-dimensional temperature distributions of 53 resuspended RBC units (mean volume, 253 ± 17 mL) were measured noninvasively by magnetic resonance thermometry. Warm-up temperature maps were visualized and analyzed by dedicated software. RESULTS: Mean times when surface, mean, and core temperature exceeded 10°C were 16 ± 4, 24 ± 5, and 36 ± 7 minutes, respectively. Times strongly correlated with each other (r = 0.78-0.95) and their variances mainly depended on RBC storage temperature and RBC pouch width (R(2) = 0.81-0.89). Measured mean temperature time courses were well described by a lumped capacitive model of heat transfer with a sample width-dependent time constant τ(RBC) = 56.3 ± 3.5 minutes (mean R(2) = 0.996). CONCLUSION: Times when RBC surface, mean, and core temperature exceed 10°C can be estimated from each other. Moreover RBC mean temperature can be calculated for arbitrary storage and ambient temperatures. Findings might serve as a helpful tool in RBC temperature monitoring.


Asunto(s)
Conservación de la Sangre/métodos , Eritrocitos/citología , Eritrocitos/metabolismo , Temperatura , Recuento de Eritrocitos , Humanos , Programas Informáticos
20.
Radiology ; 236(1): 276-83, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15955855

RESUMEN

PURPOSE: To prospectively evaluate accuracy of three-dimensional (3D) ultrasonography (US) for assessment of relative renal size in infants and children with hydronephrosis. MATERIALS AND METHODS: Informed consent was obtained from parents and also from children who were older than 8 years. Study was approved by ethics committee. Two-dimensional (2D) US, 3D US, and scintigraphy were performed in 40 patients with hydronephrosis (age range, neonate to 16 years; seven girls, 33 boys) without acute renal disease. Twenty patients also underwent magnetic resonance (MR) urography. US and MR urography were performed by one experienced pediatric radiologist; 3D US and MR urographic volume calculations were performed by specifically trained radiologists. Three-dimensional US was performed with integrated 3D volume probes or external system based on electromagnetic positioning devices. At 2D US, kidney volume was calculated with application of ellipsoid equation. At MR urography and 3D US, real renal parenchymal volume was calculated with subtraction of dilated collecting system. Split renal function was assessed with static renal scintigraphy. Three-dimensional US results were graded with respect to image quality and compared with results of 2D US, scintigraphy, and MR urography by using mean difference percentage and standard deviation of the difference. All investigations were performed with blinding. Inter- and intraobserver variability were calculated with coefficient of variation. RESULTS: In 76 of 80 kidneys, 3D US image of diagnostic quality was obtained. Three-dimensional US volume measurements compared well with MR urographic measurements (mean difference, -2.5% +/- 7.8 [standard deviation] vs 25.8% +/- 32.2 for 2D US) and with scintigraphically assessed split renal function (mean difference, 1.2% +/- 9.2 vs 15.9% +/- 43.8 for 2D US). Intra- and interobserver variability were +/-6.4% and +/-9.9%, respectively. CONCLUSION: Initial experience with renal 3D US indicates that it is an accurate method for assessment of renal parenchymal volume and relative renal size, provided there is no acute renal disease.


Asunto(s)
Hidronefrosis/diagnóstico por imagen , Imagenología Tridimensional , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Imagen por Resonancia Magnética , Masculino , Estudios Prospectivos , Cintigrafía , Estadísticas no Paramétricas , Ultrasonografía , Urografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...