Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
ACS Biomater Sci Eng ; 10(2): 782-790, 2024 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-38262427

RESUMEN

Ten MeV electron beam treatment facilitates a biomimetic introduction of cross-links in collagenous biopolymer systems, modifying their viscoelastic properties, mechanical stability, and swelling behavior. For reconstituted collagen type I fibers, electron-induced cross-linking opens up new perspectives regarding future biomedical applications in terms of tissue and ligament engineering. We demonstrate how electron irradiation affects stiffness both in low-strain regimes and in postyield regimes of biocompatible reconstituted rat tail collagen type I fibers. Stress-strain tests show a dose-dependent increase in modulus in the nonlinear elastic response, indicating a central role of induced cross-links in mechanical stability. Environmental scanning electron microscopy after fiber rupture reveals aligned distributed collagen fibril domains under the fiber surface for as-prepared fibers, accompanied by a ductile fracture behavior, whereas, in tensile tests imaged by light microscopy after 10 MeV electron treatment, isotropic network topologies are observed until the occurrence of a brittle type of rupture. Based on the biomimicry of the process, these findings might pave the way for a novel type of synthesis of tailored tendon or ligament substitutes.


Asunto(s)
Colágeno Tipo I , Colágeno , Ratas , Animales , Electrones , Matriz Extracelular , Tendones/fisiología
2.
BMC Gastroenterol ; 12: 80, 2012 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-22734948

RESUMEN

BACKGROUND: Screening colonoscopy effectiveness is hampered by limited adherence by the general population. The present prospective study was performed to evaluate whether adding capsule colonoscopy to the endoscopic screening options increases uptake. METHODS: Invitation letters were sent to 2150 persons above the age of 55 insured with a German medical insurance company in the area of Rinteln, Lower Saxony with a baseline spontaneous annual screening colonoscopy uptake of 1 %. Both capsule or conventional colonoscopy were offered. Interested persons were given information about the two screening options by four local gastroenterologists and examinations were then performed according to screenees' final choice. RESULTS: 154 persons sought further information, and 34 and 90 underwent conventional and capsule colonoscopy, respectively. Colonoscopy uptake was thus increased by the invitation process by 60 % (1.6 % vs. 1 %; p = 0.075), while the option of capsule endoscopy led to a fourfold increase of screening uptake (4.2 % vs. 1 %, p < 0.001). Despite similar age distribution in both sex groups, uptake in men was significantly higher (5.6 % vs. 2.8 %, p = 002). However, overall adenoma yield was not different in both groups. CONCLUSIONS: The present study suggests that offering the option of capsule colonoscopy increases uptake of endoscopic colorectal cancer screening. However, capsule endoscopy sensitivity for adenoma detection needs to be improved.


Asunto(s)
Adenoma/diagnóstico , Endoscopía Capsular/métodos , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Participación de la Comunidad/estadística & datos numéricos , Detección Precoz del Cáncer/métodos , Adenoma/epidemiología , Anciano , Neoplasias Colorrectales/epidemiología , Femenino , Alemania , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Aceptación de la Atención de Salud/estadística & datos numéricos , Estudios Prospectivos , Sensibilidad y Especificidad , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...