Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Talanta ; 129: 575-8, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25127635

RESUMEN

In this work, the recently introduced low flow inductively coupled plasma optical emission spectrometry (ICP-OES) with a total argon consumption below 0.7 L/min is applied for the first time to the field of food analysis. One goal is the investigation of the performance of this low flow plasma compared to a conventional ICP-OES system when non-aqueous samples with a certain matrix are introduced into the system. For this purpose, arsenic is determined in three different kinds of fish samples. In addition several nutrients (K, Na, Mg, Ca) and trace metals (Co, Cu, Mn, Cd, Pb, Zn, Fe, and Ni) are determined in honey samples (acacia) after microwave digestion. The precision of the measurements is characterized by relative standard deviations (RSD) and compared to the corresponding precision values achieved using the conventional Fassel-type torch of the ICP. To prove the accuracy of the low flow ICP-OES method, the obtained data from honey samples are validated by a conventional ICP-OES. For the measurements concerning arsenic in fish, the low flow ICP-OES values are validated by conventional Fassel-type ICP-OES. Furthermore, a certified reference material was investigated with the low gas flow setup. Limits of detection (LOD), according to the 3σ criterion, were determined to be in the low microgram per liter range for all analytes. Recovery rates in the range of 96-106% were observed for the determined trace metal elements. It was proven that the low gas flow ICP-OES leads to results that are comparable with those obtained with the Fassel-type torch for the analysis of food samples.


Asunto(s)
Análisis de los Alimentos/métodos , Contaminación de Alimentos/análisis , Microondas , Espectrofotometría/métodos , Animales , Argón/química , Calibración , Diseño de Equipo , Peces , Gases , Miel/análisis , Iones/análisis , Límite de Detección , Metales/análisis , Óptica y Fotónica , Reproducibilidad de los Resultados , Oligoelementos/análisis , Agua/química
2.
Environ Sci Technol ; 43(8): 2884-90, 2009 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-19475966

RESUMEN

The behavior of Gd chelates used in magnetic resonance imaging (MRI) within the process of sewage treatment is widely unknown. Due to the varying toxicity of the particular Gd species [J. M. Idee et al. Fundam. Clin. Pharmacol. 2006, 20, 563-576], it is important to not only investigate total Gd concentrations, but the Gd species as well. This work describes a novel method for speciation analysis of the most important gadolinium chelates in wastewaters. This novel approach consists of coupling hydrophilic interaction chromatography (HILIC) with inductively coupled plasma mass spectrometry (ICP-MS). HILIC/ICP-MS exhibits high separation efficiency for the simultaneous separation of the five predominantly applied MRI contrast agents and the required selectivity and sensitivity for trace determination in wastewater samples. For the first time, the distribution of particular Gd chelate complexes was determined in hospital effluent, municipal sewage, and wastewater treatment plant (WWTP) samples. The data were compared with the total concentration of Gd as determined by ICP-MS. The active compounds of Multihance, Dotarem, and Gadovist were identified in local WWTP samples. Interestingly, the macrocyclic, nonionic compound Gd-BT-DO3A (Gadovist) was found to be the most abundant Gd complex in all investigated samples. This is in contrast to prevalent assumptions that linear ionic Gd chelates such as Gd-DTPA (Magnevist) would be the predominant species [G. Morteani et al. Environ. Geochem. Health 2006, 28, 257-264 and M. Bau and P. Dulski, Earth Planet. Sci. Lett. 1996, 143, 245-255]. Although contrast agent concentrations tend to be reduced during wastewater treatment, Gd-BT-DO3A was still found in WWTP effluents.


Asunto(s)
Quelantes/química , Gadolinio/química , Hospitales , Residuos Industriales , Espectrometría de Masas/métodos , Aguas del Alcantarillado , Contaminantes Químicos del Agua/química , Estándares de Referencia
3.
Anal Chem ; 80(24): 9769-75, 2008 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-19072274

RESUMEN

For the risk assessment of drug candidates, the identification and quantification of their metabolites is required. The majority of analytical techniques is based on calibration standards for quantification of the metabolites. As these often are not readily available, the use of inductively coupled plasma mass spectrometry (ICPMS) is an attractive alternative for drugs containing heteroatoms. In this work, the online coupling of electrochemistry (EC), liquid chromatography (LC), and ICPMS is presented. The antiarrhythmic agent amiodarone, which contains two iodine atoms, is oxidized in an electrochemical flow-through cell under N-dealkylation and deiodination. The metabolites that are generated at different EC potentials are identified by electrospray ionization (ESI) mass spectrometry, compared to those from rat liver microsomal incubations and quantified by ICPMS. Phase-optimized LC, a recent approach for high-performance isocratic separations, is used to avoid the ICPMS calibration problems known to occur with gradient separations. The potential of the complementary use of ESI-MS and ICPMS for the qualitative and quantitative analysis of drug metabolites becomes apparent in this work.


Asunto(s)
Amiodarona/análisis , Antiarrítmicos/análisis , Electroquímica , Yodo/química , Espectrometría de Masa por Ionización de Electrospray , Amiodarona/metabolismo , Animales , Antiarrítmicos/metabolismo , Cromatografía Liquida , Microsomas Hepáticos/metabolismo , Ratas
4.
Anal Chem ; 80(21): 8163-70, 2008 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-18821778

RESUMEN

The first analytical method for simultaneous speciation analysis of five of the most important gadolinium-based magnetic resonance imaging (MRI) contrast agents in blood plasma samples was developed. Gd-DTPA (Magnevist), Gd-BT-DO3A (Gadovist), Gd-DOTA (Dotarem), Gd-DTPA-BMA (Omniscan), and Gd-BOPTA (Multihance) were separated by hydrophilic interaction liquid chromatography (HILIC) and detected with electrospray mass spectrometry (ESI-MS). Spiking experiments of blank plasma with Magnevist and Gadovist were performed to determine the analytical figures of merit and the recovery rates. The limits of detection ranged from 1 x 10 (-7) to 1 x 10 (-6) mol/L depending on the ionization properties of the individual compounds, and limits of quantification ranged from 5 x 10 (-7) to 5 x 10 (-6) mol/L. The linear concentration range comprised 2 orders of magnitude. With application of this method, blood plasma samples of 10 healthy volunteers, with Magnevist or Gadovist medication, were analyzed for Gd-DTPA and Gd-BT-DO3A, respectively. The obtained results were successfully validated with inductively coupled plasma-optical emission spectroscopy (ICP-OES).


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Medios de Contraste/análisis , Medios de Contraste/metabolismo , Gadolinio/sangre , Interacciones Hidrofóbicas e Hidrofílicas , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Cromatografía Líquida de Alta Presión/instrumentación , Medios de Contraste/química , Femenino , Gadolinio/química , Humanos , Masculino , Persona de Mediana Edad , Estructura Molecular
5.
Electrophoresis ; 29(12): 2731-7, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18512677

RESUMEN

CE was coupled to inductively coupled plasma MS (ICP-MS) and ESI-MS to identify and quantify the arsenic species arsenobetaine (AsB), arsenite (As(III)), arsenate (As(V)), and dimethylarsinic acid (DMA). A GC-flame ionization detector (FID)-based German standard method and ICP-MS were used for validation of the data obtained for arsenobetaine and total arsenic, respectively. LODs obtained with the CE-ESI-TOF-MS method were 1.0x10(-7) M for AsB, 5.0x10(-7) M for DMA, and 1.0x10(-6) M for As(III) and As(V). For the CE-ICP-MS method, LODs were 8.5x10(-8) M for AsB, 9.5x10(-8) M for DMA, 9.3x10(-8) M for As(III), and 6.2x10(-8) M for As(V). While CE-ICP-MS provided high sensitivity and better reproducibility for quantitative measurements, CE-ESI-MS with a TOF mass analyzer proved to be valuable for species identification. With this setup, fish samples were prepared and analyzed and the obtained data were successfully validated with the independent methods.


Asunto(s)
Arsenicales/análisis , Peces , Animales , Arseniatos/análisis , Arsenitos/análisis , Ácido Cacodílico/análisis , Electroforesis Capilar , Espectrometría de Masas/métodos
7.
Anal Bioanal Chem ; 388(8): 1605-13, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17593358

RESUMEN

A demountable design of the static high sensitivity ICP (SHIP) for optical emission spectrometry is presented, and its use as an excitation source with the introduction of wet aerosols was investigated. Aerosols were produced by standard pneumatic sample introduction systems, namely a cross flow nebulizer, Meinhard nebulizer and PFA low flow nebulizer, which have been applied in conjunction with a double pass and a cyclonic spray chamber. The analytical capabilities of these sample introduction systems in combination with the SHIP system were evaluated with respect to the achieved sensitivity. It was found that a nebulizer tailored for low argon flow rates (0.3-0.5 L min(-1)) is best suited for the low flow plasma (SHIP). An optimization of all gas flow rates of the SHIP system with the PFA low flow nebulizer was carried out in a two-dimensional way with the signal to background ratio (SBR) and the robustness as optimization target parameters. Optimum conditions for a torch model with 1-mm injector tube were 0.25 and 0.36 L min(-1) for the plasma gas and the nebulizer gas, respectively. A torch model with a 2-mm injector tube was optimized to 0.4 L min(-1) for the plasma gas and 0.44 L min(-1) for the nebulizer gas. In both cases the SHIP system saves approximately 95% of the argon consumed by conventional inductively coupled plasma systems. The limits of detection were found to be in the low microgram per litre range and below for many elements, which was quite comparable to those of the conventional setup. Furthermore, the short-term stability and the wash out behaviour of the SHIP were investigated. Direct comparison with the conventional setup indicated that no remarkable memory effects were caused by the closed design of the torch. The analysis of a NIST SRM 1643e (Trace Elements in Water) with the SHIP yielded recoveries of 97-103% for 13 elements, measured simultaneously.

8.
Anal Chim Acta ; 583(2): 319-25, 2007 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-17386562

RESUMEN

A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min(-1) in contrast to 15 L min(-1) using conventional ICP sources. The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source. Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44+/-0.04 and 3.19+/-0.21 microg g(-1) for Co and Mn in the CRM 075c and 2.32+/-0.09, 81.8+/-0.4, 32.2+/-3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.


Asunto(s)
Técnicas de Química Analítica/métodos , Óptica y Fotónica , Oligoelementos/análisis , Técnicas de Química Analítica/instrumentación , Óptica y Fotónica/instrumentación
9.
Biophys Chem ; 126(1-3): 124-31, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16757092

RESUMEN

Apparent thermodynamics of association of DNA-modified gold nanoparticles has been characterized by UV spectroscopy and dynamic light scattering (DLS). Extinction coefficients of unlabelled and DNA-labelled gold nanoparticles have been determined to permit quantitative analysis of the absorption measurements. In contrast to previous studies the associating gold nanoparticles were furnished with complementary oligonucleotide DNA single strands. This resulted in direct complex formation between the nanoparticles on mixing without the requirement of a DNA linker sequence for initiation of cluster formation. Melting curves of the nanoparticle assemblies formed at different temperatures were subjected to two-state analysis. A comparison of the apparent thermodynamic parameters obtained for the dissociation of these aggregates suggests that both thermodynamically and structurally different nanoparticle clusters are obtained depending on the temperature at which assembly proceeds. The van't Hoff enthalpies permit an estimate of the DNA duplexes: gold nanoparticle ratio involved in network formation.


Asunto(s)
ADN de Cadena Simple/química , Oro/química , Nanopartículas/química , Termodinámica , Estructura Molecular , Espectrofotometría Ultravioleta , Temperatura de Transición
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...